Shape
8Pages

{{requestButtons}}

Catalog excerpts

Shape - 1

Lauder LINEA panels and systems for suspended ceilings process bois

Open the catalog to page 1
Shape - 2

Lauder LINEA Solid wood Each panel is unique and may have surface irregularities which guarantee that real wood, a natural and living material, has been used. Pine Homogeneous, knot-free, pale wood, clearly visible grain patterning, straight fine to medium grain. Oak Hardwood, moderately heterogeneous, light brown to varying shades of dark brown, with a very specific straight medium grain. Finishes Wax Color finish on Pine Care for and enhance the material through factory application of the Wax Color process. A wide range of wood tone colours for a durable impressive natural...

Open the catalog to page 2
Shape - 3

Technical specifications Suspended ceiling conformity Acoustic performance Sound absorption is measured as defined in standard ISO 354. Acoustic data is calculated as defined in standard ISO 11654. Acoustic performance Class A. Performance obtained with insertion of 120 kg/m3 rigid mineral or stone wool acoustic tiles with black fleece facing (600 x 600 mm format; 20 or 22 mm thick). Slat section Facing side Thickness Spacing between slats Slat distance Total thickness Average void area The products in the Lauder LINEA ceiling range conform to EN 13964 for suspended ceilings, which is...

Open the catalog to page 3
Shape - 4

Three miscibles modules; also combinable with the Lauder LINEA 2.6.6 model

Open the catalog to page 4
Shape - 7

Suspended ceiling installation The ceiling will be installed on a grid of T24 main runners with black capping, concealed by a patented system, compliant with current standards and good practice rules in each country. The T24 main runners will be fixed at a distance of 600 mm, “D1”. The main runner components will be suspended by Ø 6 mm threaded rods hung at maximum distance «P» of 1,200 mm in a staggered configuration. The distance between the main runners will be maintained by a minimum of 1 cross bar per panel. The cross bars must be positioned at a maximum distance of 200 mm from the...

Open the catalog to page 7
Shape - 8

Removal of Lauder LINEA panels Step 2: shift the panel sideways Step 3: lower the panel to remove it Step 4: note that the cross bat is detached Step 5: position it on the adjacent panel Step 6: attach the cross bar above the adjacent panel Phone : +33 (0)2 33 42 09 52 Fax : +33 (0)2 33 42 15 69 Email : info@laudescher.com www.laudescher-industrie.com Patents covering the brands, ranges, products, systems, references and drawings in this folder have been filed with the INPI and EPO. Industrial and intellectual property and exclusive right of exploitation of Laudescher Industrie. Step 1:...

Open the catalog to page 8

All Process Bois by Laudescher catalogs and technical brochures

  1. Lauder LINEA

    84 Pages

  2. Lauder PAREA

    52 Pages