video corpo

MacBAT 5

MacBAT 5

MacBAT 5

Product catalog summary
Overview: The MacBAT 5 is a gas volume corrector designed for PTZ, PT, or T conversion, measuring gas volume, energy, and flow. It is primarily battery-powered but can connect to an external power supply. The device is suitable for explosive hazardous zones and supports various gas meters.
Specifications: The device features a polycarbonate or metal enclosure, operates in temperatures from -25°C to 70°C, and has an IP66 protection class. It includes a backlit graphic display, multiple transmission ports, and supports several communication protocols like MODBUS and GAZMODEM.
Measurement and Conversion: MacBAT 5 uses algorithms such as SGERG-88 and AGA8-92DC for gas compressibility calculations. It supports data logging with intervals from 1 to 60 minutes and stores data for over 10 years.
Inputs and Outputs: The device includes multiple digital inputs and outputs, pressure and temperature sensors, and supports both internal and external transducers. It can operate with various gas meters using different input types like LF, HF, and NAMUR.
Communication and Accessories: MacBAT 5 features built-in GSM/GPRS modems and supports remote data readout via interfaces like RS485 and NFC. Accessories include OptoBTEx for Bluetooth communication, eWebTEL for data visualization, and extension modules for additional inputs and outputs.
Software: ConfIT! software allows for configuration and diagnostics of PLUM devices, supporting firmware upgrades and storing device profiles for easy navigation.
See more

Catalog excerpts

MacBAT 5-1

MacBAT 5Gas volume and energy electronic conversion device with integrated GSM 2G/3G/4G LTE modem MacBAT 5 is a gas volume corrector that enables PTZ, PT or T conversion. The device is designed to measure volume, energy and flow of gas. Primarily battery powered with the possibility to connect external power supply. The device converts the volume of gas counted by the gas meter (turbine, rotary, ultrasonic) into the base conditions. Gas compressibility factor is calculated with the use of algorithms SGERG-88, MGERG-88, AGA8-92DC, AGA8-G1, AGA8-G2, AGA NX-19 mod or constant value of relative compression factor. MacBAT 5 is an intrinsically safe device ready to be installed in explosive hazardous zone 0. Main features of the MacBAT 5 • Industrial housing cooperates with various types of gas meter like turbine, rotary, ultrasonic directly by LF, HF, Namur, Encoder, Wiegand • 4 independent serial transmission ports (2xRS485 + OPTICAL INTERFACE 62056-21+ NFC IEC 14443) • Built-in GSM/GPRS modem (option) • Backlight graphic display • 6 configurable binary Ex inputs • 2 configurable binary NAMUR Ex inputs (operating on battery mode) • Binary and frequency outputs • Internal or external pressure transducers available • More than 10 years of archive registered data storage (with monthly sampling interval) PLUM Sp. z o.o. Wspolna 19, Ignatki, 16-001 Kleosin, Poland [email protected] www.plummac.com

 Open the catalog to page 1
MacBAT 5-2

@PLUI17* Technical specification Dimensions / weight Housing material Relative humidity Ambient temperature range Housing protection class Keyboard Display Ex classification Internal EVC supply Internal GSM supply External supply Transmission ports 206x194x76 mm / 1,3 kg Polycarbonate enclosure (version 1) or metal (version 2) max 95% at temp. 70°C -25°C up to 70°C IP 66 (for outdoor installation) 6 pushbuttons (version 1) or 18 pushbuttons (version 2) LCD - graphic 4” with backlight €> II 1G Ex ia I IB T4 Ga Certificate FTZU 17 ATEX 0047X D-size lithium battery 3,6V/17Ah (up to 3 batteries in...

 Open the catalog to page 2
MacBAT 5-3

Gas Communication 1. Direct transfer of data to system – Data readout through internal GSM/GPRS modem with the use of internal batteries Ex SCADA or Billing system 2. Remote data readout – connection through communication interfaces INT-S3, RTU controller independently Ex 2xDO: Converted volume pulse retransmission (counters Vb ) conversion alarm RS 485 3. Process of measurement using MacBAT 5 and turbine gas meter GSM/GPRS/SMS Pressure monitoring after reduction ENCODER HF Pressure-reducing valve Temperature measurement Pressure measurement 4. Process of measurement using MacBAT 5 (with external...

 Open the catalog to page 3
MacBAT 5-4

Gas MacBAT 5 accessories INT-S3 | Transmission interface Performs as an external power supply to the intrinsically safe measurement device (located in stationary telemetric systems supplied from 11-30V DC or a battery that is located in explosive zone 0, 1, or 2). Additionally, data is transmittable to a readout device (i.e. computer) via RS485 port. EM-1 | Extension module Extends the functionality of MacBAT 5 by adding two additional current outputs operating in 4-20mA current loop and four binary relay type outputs. Can operate as a standalone device as it has its own parameters that can be...

 Open the catalog to page 4

All PLUM Sp. z o.o. catalogs and technical brochures

  1. SCP V

    2  Pages

  2. SVOC EX1

    1  Page

  3. SRHT IN1

    1  Page

  4. ecoVENT

    4  Pages

  5. ecoSTER 200

    2  Pages

  6. eSTER_x40

    2  Pages

  7. ecoMAX 800R

    2  Pages

  8. 850i v12

    4  Pages

  9. ecoMAX 200D

    2  Pages

  10. ecoMAX_800P

    2  Pages

  11. ecoTOUCH 800P

    6  Pages

  12. ecoNET 300

    4  Pages

  13. Solar systems

    16  Pages

  14. Fireplaces

    20  Pages

  15. Pellet

    6  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.