Catalog excerpts
ecoPRESS EX1-02 Differential pressure transmitter The ecoPRESS EX1-02 transmitter is used to measure the differential pressure value. Reading the pressure value and configuration of transmitter parameters is done by means of Modbus RTU protocol, in RS485 standard. Modbus registers include, among others, information on the currently set measuring range, time constant, percentage value of pressure difference related to the range and signaling of exceedances of the sensor’s measuring range. The transmitter enables reading the value of differential pressure with the use two of voltage analogue output (0-10V). The transmitter cooperates with the ventilation system controllers and any industrial automation. Functions • • • • • • • • • • • • • • Two built-in differential pressure sensors. Controlling of constant flow and detection of the degree of filter contamination. Converting differential pressure to flow. Two analogue voltage output 0-10 VDC to read the value of voltage proportional to the measured pressure. Possibility of setting one of eight available ranges of voltage output 0-10 VDC. The LED indication of the operating status of the transmitter. Zero point calibration. Communication in the RS485 standard with any industrial automation. Wide range of transmitter power supply voltage. Cooperation with controllers from the ecoVENT series and configuration of transmitter parameters from the controller service menu. Supplying the transmitter from an external power supply or directly from the controller socket. Possibility of setting the time constant of measurement. Optional reading of values and configuration of transmitter parameters using Modbus RTU protocol. Installation on flat surface. Technical specifications Supply voltage / Current consumption Protection level / Protection class Ambient temperature Storage temperature Relative humidity 5…85%, without steam condensation Measuring range Measurement accuracy -500 Pa [±2.5 % range]; -2500 Pa [±1.5 % range]; -7000 Pa [±1.5 % range] Analog output Two analog outputs 0-10 VDC (one per each sensor) Digital transmission connector Screwed in 5 mm grid; wire cross-section from 0.5 mm2 to 1.5 mm2; tightening torque 0.4 Nm, isolation length 6 mm Dimensions (without dampers) Contamination level Software class PLUM Sp. z o.o. ul. Wspólna 19, Ignatki, 16-001 Kleosin, Poland plum@plum.pl www.plum.pl National Waste Database No. 000009381
Open the catalog to page 1Specifications Configuration of the SW1/ SW2 switch jumpers Electrical connection Example application Measurement of overpressure or underpressure Filter/Throttle Differential pressure measurement Fan Differential pressure measurement PLUM Sp. z o.o. reserves the right to introduce amendments in construction of the devices, without prior notice. Functions indicated above are for illustrative purpose only, they are adjusted depending on Manufacturer/Producer and software of system concerned. Contracting entity is obliged to inform
Open the catalog to page 2All PLUM Sp. z o.o. catalogs and technical brochures
-
SCP V
2 Pages
-
SVOC EX1
1 Pages
-
SRHT IN1
1 Pages
-
ecoPRESS EX1-01
2 Pages
-
MacBAT 5
4 Pages
-
ecoVENT
4 Pages
-
ecoVALVETRONIC
2 Pages
-
ecoSTER 200
2 Pages
-
eSTER_x40
2 Pages
-
ecoMAX 800R
2 Pages
-
ecoKOM 200 Classic
2 Pages
-
850i v12
4 Pages
-
ecoMAX 200D
2 Pages
-
Pellets_Biomass_Coal
32 Pages
-
ecoMAX_800P
2 Pages
-
ecoTOUCH 800P
6 Pages
-
Research project
13 Pages
-
ecoNET 300
4 Pages
-
Solar systems
16 Pages
-
Fireplaces
20 Pages
-
Wood gasification
4 Pages
-
Pellet
6 Pages
-
Folder heat pumps
4 Pages