
Simplicity and ultra-efficiency make Philips LED tubes the quickest and easiest way to upgrade to LED for immediate energy savings over a long and reliable lifetime.
Open the catalog to page 1LED tubes only use around half the energy of fluorescent alternatives, so the instant energy savings from a lamp replacement can pay for the new tubes within a couple months. From 24/7 usage downwards, it’s the installation costs and tube lifetimes that overwhelmingly set actual repayment times. Our portfolio of Philips LED tubes covers the widest range of applications. It now includes the MASTER LEDtube T8 Ultra Efficiency range for the world’s best-in-class lumen performance of up to 172 lm/W. It also includes new options in the MASTER LEDtube T5 range to cover even more applications. The new...
Open the catalog to page 2Read more about the APCOA case study: The switch to LED technology has been a resounding success. By 2020, we will be saving more than 21 million kWh of electricity and 12,000 metric tons of CO2 in Germany.” Dr. Marko Huber, Head of Technical Asset Management, APCOA MASTER LEDtube Ultra Efficiency range The MASTER LEDtube Ultra Efficiency range has been designed for the world’s best-in-class lumen performance of up to 172 l/W. With an ultra-long lifetime of 60,000 hours, these lamps offer a high lumen output along with the best Total Cost of Ownership over lifetime. Ideal for ultra-demanding...
Open the catalog to page 3The installer’s choice If you’re an installer there are even more reasons for you to choose Philips LED tubes. As you’d expect from the world’s leading name in lighting, our quality and attention to detail mean that we can also make your life safer and easier. Pin safety With Philips products you can safely touch the other end-cap when installing the tube. The integrated driver is also safely isolated from touchable parts. Philips LED tubes adhere to all UL and IEC pin safety requirements. Rotating end-caps In many applications the pin fitting needs to be rotated. This can be a problem as LED...
Open the catalog to page 4Finding the right fit for T8 tubes 1 Does your luminaire have a starter? This illustration shows its typical location in an open or closed luminaire with 1200 and 1500 mm tubes. The luminaire works with ElectroMagnetic ballasts. Simply replace the old starter with the new (EM) LED starter included in the packaging. Choose the LED tube with one ring on the cap. The luminaire works on High Frequency (HF) electronic ballasts. Choose MASTER LEDtube InstantFit with the end-cap with two rings. No need to change drivers or rewire. It’s a plug and play solution that works straight out of the box. Quick...
Open the catalog to page 5Car Park > Burning hours: 24/7 > Ensure visibility and feeling of safety > Need for energy reduction and reducing maintenance costs > Withstand cold (er) temperatures > Light requirement: 200+ lux Supermarket / Retail > Burning hours: 12 hrs /a day to 24/7 > Enhance ‘green’ image of the brand > Need for energy reduction and reducing maintenance costs > Product enhancement on the shelf > Shatterproof thanks to plastic material > Light requirement: 500+lux Office / School / Healthcare > Burning hours: usually 12 hrs /a day > Need for energy reduction and reducing maintenance costs > High quality...
Open the catalog to page 6Best energy saving Best light output CorePro Standard Output Best light output Best light output and best energy efficiency over lifetime MASTER Ultra Output Best energy saving Best light output Best light output and best energy efficiency over lifetime MASTER Ultra Output Best energy saving Best light output Best light output and best energy efficiency over lifetime MASTER High Output Best energy saving MASTER Ultra Output CorePro Standard Output MASTER High Output MASTER High Output Up to 3100 lumen MASTER Ultra Efficiency MASTER High Output MASTER Ultra Efficiency MASTER High Output MASTER...
Open the catalog to page 7Finding the right output For ultra-output applications, our solutions meet lighting industry standards (EN12464-1) by providing high light levels without causing discomfort or glare*. Lux Unified Glare Rating (UGR) Working, typing reading and data processing require sufficient light with a minimum lux level The amount of glare, annoyance or reflection created by high or non-uniform brightness must be kept to a minimum Sufficient light › ey parameter for K minimum required light is indicated in EN12464-1 in lux (lumens per square meter). › N12464-1 prescribes E minimum lux values, uniformity of...
Open the catalog to page 8The most affordable switch The new generation of CorePro LED tubes T8 feature a shorter aluminium end cap and provide a wide beam of 240 degrees for a uniform light effect. With low energy consumption and an increased performance of up to 110 l/W, they’re our most affordable LED tubes for budget applications like garages and storerooms, enabling immediate energy savings and a faster payback time. Now available with shorter end caps 240˚ beam angle ››Uniform light spread for car parks, storage rooms, ü Glass housing warehouses ü Uniform light spread ››Not for high lux applications for car parks,...
Open the catalog to page 9Finding the right solution for your application High output on the high street Retail stores and hospitality venues know light has the power to attract. It creates irresistible displays, brings brands to life and encourages customers to spend longer in store. With our LED tubes you can light up sales at the same time as reducing energy and maintenance costs. Fluorescent TL-D 1500 mm High Output 2100 - 3100 lumen Savings / year per lamp Payback period Total costs / year Energy costs Average buying price installer ex VAT Burning hours per year Energy savings Longer lifetime Based on the European...
Open the catalog to page 10High output for offices With a light output of up to 3100 lumen, our High Output LED tubes provide brilliant light quality with the best lumen per watt. A simple switch for offices and healthcare settings that saves on energy but feels bright and welcoming. Fluorescent TL-D 1500 mm High Output 2100 - 3100 lumen Savings / year per lamp Payback period Total costs / year Energy costs Average buying price installer ex VAT Burning hours per year Energy savings Longer lifetime Based on the European average of 12 cent/kW hour (including maintenance and lamp replacement cost) › Choose High Output LED...
Open the catalog to page 113 Pages
3 Pages
3 Pages
3 Pages
3 Pages
2 Pages
3 Pages
2 Pages
2 Pages
3 Pages
4 Pages
5 Pages
6 Pages
9 Pages
13 Pages
7 Pages
5 Pages
3 Pages
2 Pages
3 Pages
3 Pages
2 Pages
2 Pages
5 Pages
6 Pages
2 Pages
1 Page
61 Pages
6 Pages
7 Pages
5 Pages
8 Pages
7 Pages
5 Pages
8 Pages
20 Pages
19 Pages
17 Pages
44 Pages
52 Pages
11 Pages
32 Pages
25 Pages
7 Pages
37 Pages
5 Pages
31 Pages
92 Pages
4 Pages
4 Pages
40 Pages
20 Pages
37 Pages
28 Pages
25 Pages
32 Pages
46 Pages
2 Pages
2 Pages
5 Pages
12 Pages
200 Pages
102 Pages
87 Pages