Linear Façade System

Linear Façade System

Linear Façade System

Product catalog summary
Overview: The document describes the Pfl aum Linear Façade System, emphasizing its innovative design that incorporates light, air, and a sense of weightlessness. It is adaptable for various construction needs such as refurbishment, reconstruction, and new builds, offering extraordinary architectural solutions.
System Features: The system includes a water-repellent fitted covering layer with flexible clamping connections, eliminating issues like longitudinal expansion due to temperature changes. The substructure ensures construction physics perfection with cross-section ventilation, allowing for cost-effective and quick installation.
System Components: The system offers various components such as clamping profiles and storm protection, with modular rail lengths and mounting options on masonry and liner trays. The maximum fixation distance is 600 mm.
Technical Specifications: The façade system supports different widths (200, 300, 400 mm) and weights, with specific load capacities for wind suction and element weight. The system allows for a maximum span for linear elements and requires separate approval for modular strip fastening.
Coatings and Materials: The system uses polyester or PVF coatings with corrosion protection according to EN 10169, RC3-RC5. The base material is 1.0 mm galvanized fine steel as per EN 10147.
Thermal Insulation and Fire Behaviour: The system can incorporate any thermal insulation and is classified as non-combustible (fire resistance class A) according to ÖNORM B 3800 and DIN 4102.
Dimensions and Ventilation: Standard and special widths range from 200 to 400 mm, with recommended delivery lengths up to 12,000 mm. Ventilation requirements are specified according to ÖNORM B 2219 and DIN 18516.
Quality and Approval: The system adheres to tolerances as per EN 14509 and has approval DIBt 7-14.1-566.
See more

Catalog excerpts

Linear Façade System-1

LINEAR FASSADENSYSTEM LINEAR FAÇADE SYSTEM Licht. Luft. Leichtigkeit. Es ist das Zusammenspiel dieser drei Elemente, das ein Fassadensystem in ein Pflaum Fassadensystem verwandelt. Umbau, Neubau, Ausbau, Zubau – unser Fassadensystem wächst mit den Wünschen mit. Individualisten erwarten eben mehr von Architektur. Pflaum: Mehr als Gewöhnliches; Außergewöhnliches! Light. Air. An impression of weightlessness. The Pflaum Linear façade system transforms any façade system by the interplay of these elements. Refurbishment, reconstruction, extension or building from scratch – the Pflaum façade system grows with your wishes. Individual architecture: more than ordinary; extraordinary!

 Open the catalog to page 1
Linear Façade System-2

L LINEAR FASSADENSYSTEM LINEAR FAÇADE SYSTEM The linear façade system with the durchdringungsfrei befestigten Deck- water-repellent fitted covering layer with schicht durch flexible Klemmverbind- flexible clamping connections impresses ungen macht weltweit Eindruck. anywhere in the world. Problems like Probleme der Längsdehnungen, bedingt durch Temperatur und Material, sind bei temperature and material – are ruled out diesem System ausgeschlossen. with this system. The substructure gives perfection in terms of construction physikalische Perfektion (Hinterlüftungs- physics (cross-section ventilation)....

 Open the catalog to page 2
Linear Façade System-4

Montage auf Mauerwerk Mounting on masonry max. Befestigungsabstand 600mm Maximum fixation distance 600mm Klemmprofil Clamping profile SYSTEMKOMPONENTEN SYSTEM COMPONENTS Montage auf Kassette Mounting on liner trays Klemmprofil Sturmsicherung Clamping profile Storm protection Modulleistenlängen Modular rail Ausgleichsbügel Compensation profile

 Open the catalog to page 4
Linear Façade System-5

QUERSCHNITT LINEAR FASSADENSYSTEM SECTIONAL VIEW LINEAR FAÇADE SYSTEM L-0/200 Belastungswerte Windsog Wind suction loading Elementgewicht Weight of element MODULLEISTENABSTAND MODULAR BAR DISTANCE maximale Stützweite für Linearelemente Maximum span for linear elements Baubreite Width (mm) 200 statisches charakteristische andrückende und abhebende Windlasten (kN/m²) System characteristic press-on and lifting wind loads (kN/ m²) static ±0,25 ±0,50 ±0,75 ±1,00 ±1,25 ±1,50 ±1,75 ±2,00 system 1-feld 2-feld Mehrfeld 1-feld 2-feld Mehrfeld 1-feld 2-feld Mehrfeld Zulässige Belastung bei einer max. Durchbiegung...

 Open the catalog to page 5
Linear Façade System-6

TECHNISCHE DATEN LINEAR FASSADENSYSTEM Teil 1 und Teil 4 als nicht brennbare Baustoffe der Klasse A eingestuft. ABMESSUNGEN Standardbaubreiten Basis Stahlblech 1,00 mm bandverzinktes Feinblech nach EN 10147 (275 g/m2 Zink) WÄRMEDÄMMUNG In den Konstruktionsaufbau des Linear Fassadensystems sind Wärme- nach Maß; empfohlene Lieferlänge dämmungen aller Art problemlos einzubringen. Lüftungsquerschnitt Gemäß ÖNORM B 2219 und DIN 18516 Teil 1 freier vertikaler Lüftungsquerschnitt von mind. 200 cm2/m und max. 500 cm2/m. Längsdehnung-Modulleiste Keine Spannungen auf die Unterkonstruktion durch die gleitende...

 Open the catalog to page 6
Linear Façade System-7

TECHNICAL DATA LINEAR FAÇADE SYSTEM SYSTEM STRUCTURE FIRE BEHAVIOUR fire resistance class A, non-combusti- Quality assurance according coating. Corrosion protection class and DIN 4102, part 1 and part 4. APPROVAL according EN 10169, RC3-RC5 DIMENSIONS Basis Steel Sheet Standard Widths 1.0 micron galvanised fine steel acc. to EN 10147 (275 g/m2 zinc) Special Widths THERMAL INSULATION Any kind of thermal insulation can be easily incorporated into the linear Delivery lengths façade system. on request; we recommend a maximum length of 12,000 mm Ventilation section Cross-sectional ventilation: Free...

 Open the catalog to page 7

All Pflaum & Sohne Bausysteme catalogs and technical brochures

  1. Katalog2013

    76  Pages

Archived catalogs

  1. catalogue 2012

    76  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.