URBAN
116Pages

{{requestButtons}}

Catalog excerpts

URBAN - 3

A tailor-made lighting solution for each urban area: streets, parking areas, squares, green areas, playgrounds, bridges, pedestrian streets. We create versatile urban lighting systems that combine collective and individual interests. We want to offer urban spaces a new identity, and improve the perception of those who live in and use them.

Open the catalog to page 3
URBAN - 4

AREA LIGHTING SPILLO SPILLO MINI POST STREET LIGHTING KREOS THEOS GLASS MINI

Open the catalog to page 4
URBAN - 6

ITALY: PUBLIC LIGHTING CAMs The CAMs (Italian acronym for “Minimum Environmental Criteria”) are a set of legislative acts passed by the Italian government. They set the minimum mandatory requirements that goods and services must have in order to guarantee to be purchasable by the public administrations, giving particular attention to sustainability and energy savings. The “Public Lighting CAM”, approved by the ministerial decree of the 27th September 2017, regulate the purchasing of lighting sources and fixtures, as well as the procurement of design services in public lighting...

Open the catalog to page 6
URBAN - 7

Luminaires for pedestrian areas, pedestrian pathways, cycling pathways, cycle-pedestrian areas Requirement Minimum Rewarding L80B10 --5 >5 Luminaires for green areas Artistic luminaires for historic city centers Requirement Minimum Rewarding L80B10 --5 >5 Requirement Minimum Rewarding L80B10 --5 >5

Open the catalog to page 7
URBAN - 8

IPEA* - IPEI* The ever-growing attention given by institutions and public opinion to environment related issues, has led also the lighting industry to a profound renovation. This process was brought forth not only by the diffusion of LED technology, but also by important regulatory evolutions, which have redefined the criteria to be used to evaluate efficacy and sustainability of lighting fixtures and systems. Lighting fixture efficacy (lm/W), in particular, has been understood to not be enough to obtain effective lighting systems, if considered alone.

Open the catalog to page 8
URBAN - 9

To achieve effectiveness, indeed, the lumen/Watt ratio has to be considered together with the system lighting requirements; the lighting fixtures have to be evaluated for their capacity to light up “only where is needed”, without exceeding the light levels prescribed by the regulations. Italy has given a strong contribution to this paradigmatic change by introducing, with CAM, two new energy indexes: IPEA* for fixtures and IPEI* for systems. IPEA* (Italian acronym for “Parametric Fixture Efficacy Index”) is an alphanumeric value (ex. A++), similar to the energy class of household...

Open the catalog to page 9
URBAN - 10

FRANCE: LIGHT POLLUTION LAW DECREE OF 27 DECEMBER 2018 The French government, with the law decree of 27 December 2018, has adopted a legislative provision for the reduction and limitation of light pollution, aimed at night skies preservation, intrusive light limitation, protection of biodiversity and increase of energy savings. These goals are reached through the regulation of four features of lighting fixtures and systems, which are: ULR (Uplight Lighting Ratio), CIE flux code n°3, colour temperature and light flux density. In addition, specific requirements are prescribed for astronomical...

Open the catalog to page 10
URBAN - 11

FC1 FC2 CIE n°3 FC4 F Navile public park | Bologna | Italy CIE flux codes are a photometric parameter made up of five integers (e.g. 32 74 97 100 100), which define the light distribution of a lighting fixture within certain angles. The third integer denotes the percentage of light flux emitted within an opening semiangle of 75,5°. Limiting the flux emitted above 70 ÷ 75° contributes to reduce glare and intrusive light, that is the fraction of light flux directed outside the areas which need to be lit. - Lighting installations (both public and private) as roads, which assure drivers,...

Open the catalog to page 11
URBAN - 12

FRANCE: LIGHT POLLUTION LAW DECREE OF 27 DECEMBER 2018 WARM BRIGHT WHITE WHITE Alhambra | Granada | Spain COLOUR TEMPERATURE (K) Some features of the artificial light spectrum can affect biological cycles of flora and fauna. To preserve biodiversity, the decree sets the maximum colour temperature of the light sources to be used. Colour temperature (K) Urban areas Extra-urban areas - Lighting installations of any kind inside nature reserves. - Lighting installations of any kind inside national parks. - Lighting installations (both public and private) as roads, which assure drivers, cyclists...

Open the catalog to page 12
URBAN - 13

2500 lm x 2 = 50 lm/mq 100 mq 100 mq Tank storage Standic B.V. | Dordrecht | Netherlands LIGHT FLUX DENSITY (lm/m²) Light flux density is the ratio between the summation of the fluxes of all the lighting fixtures which light up a certain area and the surface of the area itself; its measure unit is lm/m². It allows to evaluate if an installation lights up only where it’s needed without wastes, so to increase energy savings. Light flux density (lm/m²) Urban areas Extra-urban areas - Lighting installations (both public and private) as roads, which assure drivers, cyclists and pedestrians’...

Open the catalog to page 13
URBAN - 14

design Roberto Fiorato Subtraction adds value The new HEDO+ series is the latest restyling of an iconic product, aesthetically unique, characterized by minimalistic and pure design. The extensive use of voids subordinates HEDO+ to the environment: a crystal clear example where subtraction of matter adds value to the contest. The HEDO+ transforms traditional lighting by blending contemporary designs with urban styles. This minimalistic look delivers a powerful creative statement with a low environmental impact. Its exceptional design will meld into most surroundings. With proprietary optics...

Open the catalog to page 14
URBAN - 15

Jumeirah Lakes Towers | Dubai | EAU

Open the catalog to page 15
URBAN - 16

design Roberto Fiorato Area and site lighting series. Fixtures consist of: Construction - Die-cast aluminium housing, powder-polyester coated ISO 9227 - High resiliency anti-ageing silicone gasket with high elastic return capacity - Stainless steel external screws - Painted die-cast aluminium pole-top adaptor for pole Ø 60 / 76 mm Electrical - Integral surge protection device (SPD) against mains overvoltages up to 10 kV - NEMA versions are complete with NEMA SOCKET connected to DALI drivers and a waterproof short-circuit cap allowing the on-off operation of the luminaire. These versions are...

Open the catalog to page 16

All PERFORMANCE IN LIGHTING catalogs and technical brochures

  1. OFFICE

    168 Pages

  2. ARCHITECTURAL

    204 Pages