GLOBAL PX
23Pages

{{requestButtons}}

Catalog excerpts

GLOBAL PX - 1

GLOBAL PX Ventilation unit with plate heat exchanger - TAC6 Ventilation unit with counterflow heat exchanger, for commercial installations. Suitable both for new construction and when renovating existing buildings. Max. airflow 6800 m³/h (1890 l/s). Temperature efficiency above 90% (-10°C/+22°C). Temperature efficiency above 83% according to EN 308. Energy-efficient and quiet EC fans with fan impeller made of composite material or alumunium. For installation indoors or outdoors. Top quality control system with touch screen. Units up to GLOBAL PX 08 have external dimensions that allow passage through a door.

Open the catalog to page 1
GLOBAL PX - 2

HIGHLY EFFICIENT VENTILATION UNIT WITH ENERGY RECOVERY Each project has unique parameters and must satisfy different in, water heating coil or electric post-heater. The heater’s out- requirements. That is why Swegon offers a wide selection of air put is adjusted in order to maintain a constant temperature. handling units and always has a solution to match your needs. The GLOBAL units can be supplied with a factory-fitted, built- The GLOBAL series includes fans equipped with high perfor- The GLOBAL units can be supplied with factory-fitted, mo- mance direct-current motors (Total Airflow...

Open the catalog to page 2
GLOBAL PX - 3

THE CORRECT OPERATING MODE IS IMPORTANT • option. Fully integrated control complete electrical connections. HMI with intuitive commissioning configured prior to delivery from text-based assistance. EC plenum fans with fan impel- Filter class ePM1 70% for outdoor Software for unit selection is available online. ERP2018-optimised design. Conforms to the requirements in hygiene standard VDI6022. Conforms to the requirements in standard ISO EN 16890. CONSTANT PRESSURE CONSTANT AIRFLOW Whether the ventilation system is to work This operating mode is very well This operating mode is often used in...

Open the catalog to page 3
GLOBAL PX - 4

CONTROL UNIT ALTERNATIVES TACTOUCH HMI HMI with an LCD display and built-in timer control of 6 events per day. All parameters can be set and the unit can be controlled via the touch screen. Commissioning GLOBAL PX – GENERAL CIRCULAR DUCT CONNECTIONS The duct connections for sizes 05 and 08 are circular and are fitted with a rubber seal. The units can be combined with motor-driven dampers. menu, alarm history, operating parameters and error messages are presented in plain text. RECTANGULAR DUCT CONNECTIONS The standard duct connections (15 mm) for size 12 and above are rec- With the 4-mode...

Open the catalog to page 4
GLOBAL PX - 5

EC FANS WITH FAN IMPELLERS MADE OF COMPOSITE MATERIAL The EC fans have fan impellers made of composite material as stand- fitted in an insulated casing. Water-based or directly expanding (DX) ard, which provides the fan with lower specific fan power (SFP). The heaters/coolers can be used. Its output is adjusted in order to maintain benefits of composite fan impellers are their low weight and more a constant supply air or extract air temperature. The waterborne unit is aerodynamic form. Aluminium fan impellers are available as an option. supplied ready-to-connect, such as a 3-way valve,...

Open the catalog to page 5
GLOBAL PX - 6

EC PLENUM FAN MADE OF COMPOSITE MATERIAL (ALUMINIUM IS AVAILABLE AS AN OPTION) BAG FILTER FOR OUTDOOR AIR, CLASS F7 (PRE-FILTER CLASS G4 AVAILABLE AS AN OPTIONAL BUILT-IN CONTROL UNIT HINGES FOR GOOD ACCESSIBILITY 3 BASE FRAME DESIGNED SIMPLE TRANSPORT HIGHLY EFFICIENT PLATE HEAT EXCHANGER BUILT-IN POST-HEATER (WATER HEATING/ELECTRIC) BAG FILTER FOR EXTRACT AIR, CLASS M5

Open the catalog to page 6
GLOBAL PX - 7

Available external pressure (Pa) Max. speed at dim. filter pressure drop Dry temperature efficiency • AIRFLOW • ELECTRIC POWER SUPPLY • RECOMMENDED FUSE PROTECTION • FILTER CLASS (BAG FILTER) • CIRCULAR DUCT CONNECTIONS • STANDARD DUCT CONNECTIONS (15 mm) • GUIDE DUCT CONNECTIONS (20 mm) • AMBIENT TEMPERATURE Speed dim. used/Max, supply air Speed dim. POWER CON- Dry temperature used/Max, SUMPTION efficiency extract air Conditions 1. Calculated values at 200 Pa ext. pressure (150/50 Pa) 2. All data applies to fans with composite fan impeller 3. SFP and absorbed power calculated with clean...

Open the catalog to page 7
GLOBAL PX - 8

Available external pressure (Pa) Max. speed at dim. filter pressure drop Dry temperature efficiency • AIRFLOW • ELECTRIC POWER SUPPLY • RECOMMENDED FUSE PROTECTION • FILTER CLASS (BAG FILTER) • CIRCULAR DUCT CONNECTIONS • STANDARD DUCT CONNECTIONS (15 mm) • GUIDE DUCT CONNECTIONS (20 mm) • AMBIENT TEMPERATURE Speed dim. used/Max, supply air Speed dim. POWER CON- Dry temperature used/Max, SUMPTION efficiency extract air Conditions 1. Calculated values at 200 Pa ext. pressure (150/50 Pa) 2. All data applies to fans with composite fan impeller 3. SFP and absorbed power calculated with clean...

Open the catalog to page 8
GLOBAL PX - 9

Available external pressure (Pa) Max. speed at dim. filter pressure drop Dry temperature efficiency • AIRFLOW • ELECTRIC POWER SUPPLY • RECOMMENDED FUSE PROTECTION • FILTER CLASS (BAG FILTER) • CIRCULAR DUCT CONNECTIONS • STANDARD DUCT CONNECTIONS (15 mm) • GUIDE DUCT CONNECTIONS (20 mm) • AMBIENT TEMPERATURE Speed dim. used/Max, supply air Speed dim. used/Max, extract air POWER CONSUMPTION Conditions 1. Calculated values at 200 Pa ext. pressure (150/50 Pa) 2. All data applies to fans with composite fan impeller 3. SFP and absorbed power calculated with clean filter 4. Speed dim. calculated...

Open the catalog to page 9
GLOBAL PX - 10

Available external pressure (Pa) Max. speed at dim. filter pressure drop Dry temperature efficiency • AIRFLOW • ELECTRIC POWER SUPPLY • RECOMMENDED FUSE PROTECTION • FILTER CLASS (BAG FILTER) • CIRCULAR DUCT CONNECTIONS • STANDARD DUCT CONNECTIONS (15 mm) • GUIDE DUCT CONNECTIONS (20 mm) • AMBIENT TEMPERATURE Speed dim. used/Max, supply air Speed dim. used/Max, extract air POWER CONSUMPTION Conditions 1. Calculated values at 200 Pa ext. pressure (150/50 Pa) 2. All data applies to fans with composite fan impeller 3. SFP and absorbed power calculated with clean filter 4. Speed dim. calculated...

Open the catalog to page 10
GLOBAL PX - 11

Available external pressure (Pa) Max. speed at dim. filter pressure drop Dry temperature efficiency • AIRFLOW • ELECTRIC POWER SUPPLY • RECOMMENDED FUSE PROTECTION • FILTER CLASS (BAG FILTER) • CIRCULAR DUCT CONNECTIONS • STANDARD DUCT CONNECTIONS (15 mm) • GUIDE DUCT CONNECTIONS (20 mm) (W x H) • AMBIENT TEMPERATURE Speed dim. used/Max, supply air Speed dim. POWER CON- Dry temperature used/Max, SUMPTION efficiency extract air Conditions 1. Calculated values at 200 Pa ext. pressure (150/50 Pa) 2. All data applies to fans with composite fan impeller 3. SFP and absorbed power calculated with...

Open the catalog to page 11

All P. LEMMENS COMPANY catalogs and technical brochures

  1. GLOBAL LP OUT

    24 Pages

  2. GLOBAL RX TOP

    32 Pages

  3. GLOBAL RX

    44 Pages

  4. Aira

    4 Pages

  5. COMPO Series

    24 Pages

  6. CUBUS

    4 Pages

  7. AC series

    4 Pages

  8. AE series

    4 Pages

  9. AIRA series

    4 Pages

  10. BA series

    2 Pages

  11. CUBUS series

    4 Pages

  12. ES series

    2 Pages

  13. LCO series

    6 Pages

  14. REC X series

    4 Pages

  15. TV series

    4 Pages

  16. TAC series

    4 Pages

  17. COMPO series

    4 Pages