GLOBAL PX/RX/LP Operation and maintenance instructions Applicable to program versions TAC5 – Version DT 2.8.12 & DG 2.7.3 GLOBAL LP(FW) GLOBAL PXFW
Open the catalog to page 16.1 Commissioning with Touchscreen interface 2 This document is an overview of technical specifications. Please do refer to our selection software for detailed and up-to-date information.
Open the catalog to page 2This document is an overview of technical specifications. Please do refer to our selection software for detailed and up-to-date information. 3
Open the catalog to page 3Disclaimer Danger/Warning/Caution • All staff concerned shall acquaint themselves with these instructions before beginning any work on the unit. Any damages to the unit or its components caused by improper handling or misuse by the purchaser or the installer cannot be considered subject to guarantee if these instructions have not been followed correctly. • Make sure that the power supply to the unit is disconnected before performing any maintenance or electrical work! • All electrical connections must be carried out by an authorized installer and in accordance with local rules and controls....
Open the catalog to page 4PLEATED FILTER ROTARY HEAT EXCHANGER PLATE HEAT EXCHANGER Must be connected by a qualified Electrician. Warning! Hazardous voltage. HEATING COIL COOLING COIL PRESSURE SENSOR SLIP CLAMP FLEXIBLE CONNECTION CIRCULAR DUCT CONNECTION (WATER / ELECTRICAL) MOTORIZED DAMPER TEMPERATURE SENSOR This document is an overview of technical specifications. Please do refer to our selection software for detailed and up-to-date information.
Open the catalog to page 53.0 Product Overview 3.1 GENERAL OVERVIEW RIGHT HAND UNIT (SUPPLY AIR TO THE RIGHT) GLOBAL PX(FW) GLOBAL PX(FW) LEFT HAND UNIT (SUPPLY AIR TO THE LEFT) This document is an overview of technical specifications. Please do refer to our selection software for detailed and up-to-date information.
Open the catalog to page 6RIGHT HAND UNIT (SUPPLY AIR TO THE RIGHT) LEFT HAND UNIT (SUPPLY AIR TO THE LEFT) GLOBAL LP 450FW (BOTTOM view) GLOBAL LP 450FW (BOTTOM view) GLOBAL LP 600 - 2000FW (BOTTOM view) GLOBAL LP 600 - 2000FW (BOTTOM view) ATTENTION Right and left hand units have different article numbers and should be ordered accordingly. Main version described in the manuals is always the hand right version. The difference between left and right LP units is the factory placement of the controls box on opposite sides. This document is an overview of technical specifications. Please do refer to our selection...
Open the catalog to page 73.2 COMPONENTS GLOBAL PX GLOBAL PX TOPFW 1. Main power switch 2. Main power switch for electrical coils (both internal pre-hating and post-heating) 11. Drain pan and drain pipe 13. Internal post-heating water or electrical coil (accessory) 14. Motorized damper (at outdoor air side - accessory) 15. Motorized damper (at exhaust air side - accessory) 6. Kit CA -airflow measurement (option) 7. Outdoor air filter (bag or pleated) 18. Slip Clamps (accessory) 8. Extract air filter (bag or pleated) 19. Water connection for postheating (accessory) 12. Pre-heating electrical antifrost coi 9. Heat...
Open the catalog to page 8This document is an overview of technical specifications. Please do refer to our selection software for detailed and up-to-date information. 9
Open the catalog to page 9GLOBAL LPFW 1. Main power switch 2. Main power switch for electrical coils (both internal pre-hating and post-heating) 11. Drain pan and drain pipe 13. Internal post-heating water or electrical coil (accessory) 14. Motorized damper (at outdoor air side - accessory) 15. Motorized damper (at exhaust air side - accessory) 6. Kit CA -airflow measurement (option) 7. Outdoor air filter (bag or pleated) 8. Extract air filter (bag or pleated) 18. Slip Clamps (accessory) 9. Heat exchanger (Plate) 19. Water connection for postheating (accessory) 12. Pre-heating electrical antifrost coil 1, 2 and 3...
Open the catalog to page 10GLOBAL LP(FW) GLOBAL LP(FW) EXCHANGER This document is an overview of technical specifications. Please do refer to our selection software for detailed and up-to-date information. 11
Open the catalog to page 113.2 COMPONENTS GLOBAL RX GLOBAL RX 1. Main power switch 13. Internal post-heating water or electrical coil (accessory) 2. Main power switch for electrical coils (both internal pre-hating and post-heating) 14. Motorized damper (at outdoor air side - accessory) 18. Slip Clamps (accessory) 19. Water connection for postheating (accessory) 15. Motorized damper (at exhaust air side - accessory) 6. Kit CA -airflow measurement (option) 7. Outdoor air filter (bag) 8. Extract air filter (bag) 9. Heat exchanger (Rotary) 1, 2 and 3 must be installed by an accredited electrician Note: internal...
Open the catalog to page 12This document is an overview of technical specifications. Please do refer to our selection software for detailed and up-to-date information. 13
Open the catalog to page 13MAIN CONTROL BOARD TAC5 DG - CID025000BYPASS4 3 2 1 MOTOR CONTROL CABLES CT = output to CT actuator(s) (option - prewired) BYPASS = output to bypass actuator (prewired) IN2 = dPa (pressostat digital input) IN3 = Fire alarm input IN4 = Bypass open / Stop heat recovery IN5 = Real time clock auto/manu Demand/Pressure control IN6 = ON/OFF post heating (IBA/KWout) Torque MODE IN7 = ON/OFF SUPPLY if fire alarm IN8 = ON/OFF EXHAUST if fire alarm Demand/Pressure control Torque control IN12 = PWM input bypass position OUT1 = 0-10V OUTPUT (airflow / pressure) Demand/Pressure control OUT2 = 0-10V...
Open the catalog to page 14AL1 BYPASS BYPASS MOTOR CONTROL CABLES CT : output to CT actuator(s) (option - prewired) KWout = output for KWout capacity control (option - prewired) IN2 = dPa (pressostat digital input) IN3 = Fire alarm input IN4 = Bypass open / Stop heat recovery IN5 = Real time clock auto/manu Demand/Pressure control = START/STOP IN6 = ON/OFF post heating (IBA/KWout) Torque control IN7 = ON/OFF SUPPLY if fire alarm IN8 = ON/OFF EXHAUST if fire alarm Demand/Pressure control = 0-10V INPUT Torque control IN12 = input pulse from heat exchanger magnet (prewired) OUT1 = 0-10V OUTPUT (airflow / pressure) OUT2...
Open the catalog to page 154.1 CIRCUIT BOARD SAT 3 - CID372005 The SAT3 circuit board is used for extra functions for which inputs and outputs are not included as standard in the control unit of the air handling unit. All outputs are normally open (N.O.). Maximal load: 230VAC - 4A. The circuit board SAT3 allows for signalling of the following by means of a potential-free contact: • Differential pressure alarm - O.R. 2 SAT3 must be plugged onto the control board circuit (see fig.1). Attention: The SAT3 must be plugged in before the circuit is powered. SAT must be plugged in correctly, wrong positioning can damage both...
Open the catalog to page 16All P. LEMMENS COMPANY catalogs and technical brochures
-
GLOBAL PX
23 Pages
-
ROOF VENTILATOR CASA F 41-83
8 Pages
-
GLOBAL LP OUT
24 Pages
-
GLOBAL RX TOP
32 Pages
-
GLOBAL RX
44 Pages
-
Aira
4 Pages
-
COMPO Series
24 Pages
-
CUBUS
4 Pages
-
AC series
4 Pages
-
AE series
4 Pages
-
AIRA series
4 Pages
-
BA series
2 Pages
-
CUBUS series
4 Pages
-
ES series
2 Pages
-
LCO series
6 Pages
-
REC X series
4 Pages
-
TV series
4 Pages
-
Commercial brochure
8 Pages
-
TAC series
4 Pages
-
REC HRglobal series
8 Pages
-
COMPO series
4 Pages