COMPO Series
1 /24Pages

COMPO Series

COMPO Series
1 /24Pages

Catalog excerpts

COMPO Series-1

COMPO SERIES COMPO Series Technical Guide Range of compact, modular air-treatment units (0-8000 m³/h)

 Open the catalog to page 1
COMPO Series-2

COMPO SERIES The Compo range meets all your needs in air recirculation, heating or conditioning in a single airflow. Using TAC5 technology, which is standard in the COMPO series, and a smart standardisation of the various modules used in air-treatment units, PLC has developed an «almost customised» complete standardised COMPACT range of air-treatment units, from 0 to 8000 m3/h. Unlike the usual process of first defining each element that makes up a unit and then purchasing each one individually, the Compo range contains an extended stock of standard elements, which can be chosen in order to define...

 Open the catalog to page 2
COMPO Series-3

Silent, rigid, aesthetic, double-skin modular construction All COMPO devices are double-walled, insulated by 30 mm of rock wool. The structure is made of anodised-aluminium profile members, articulated around modules injected with reinforced polypropylene. COMPO SERIES The outer panels are made of pre-painted steel (RAL9002), painted with siliconised thermally crosslinkable polyester, which is corrosion resistant, and covered with a protective plastic film, to be removed after installation, and are easily detached in order to be able to access the inside parts. The inside is made of galvanised...

 Open the catalog to page 3
COMPO Series-4

GENERAL TECHNICAL SPECIFICATIONS CID • CROSS-SECTION 430X430, length 890 mm according to selection • PANEL COLOUR Beige RAL 9002 0. Available fan pressure for the 4-row heating battery 1. Total noise pressure in dBA radiated in free field at 3 m over system curve 1000 m3/h at 150 Pa 2. Water battery (2 rows) 80/60, air -10°C, 50% RH 3. Water battery (4 rows) 70/50, air -10°C, 50% RH 4. Water battery (4 rows, condensation), condensation temp. 45°C, air -10°C, 50% RH 5. Water battery 7/12, air 25°C, 50% RH 6. R410a battery, evaporation temp. 5°C, air 25°C, 50% RH AVAILABLE SOUND AIRFLOW PRESSURE...

 Open the catalog to page 4
COMPO Series-5

Fan curve DD 9-9 TAC 1/2 GENERAL TECHNICAL SPECIFICATIONS CID 845438 0. Available fan pressure for the 4-row heating battery 1. Total noise pressure in dBA radiated in free field at 3 m over system curve 1000 m3/h at 150 Pa 2. Water battery (2 rows) 80/60, air -10°C, 50% RH 3. Water battery (4 rows) 70/50, air -10°C, 50% RH 4. Water battery (4 rows, condensation), condensation temp. 45°C, air -10°C, 50% RH 5. Water battery 7/12, air 25°C, 50% RH 6. R410a battery, evaporation temp. 5°C, air 25°C, 50% RH • CROSS-SECTION 530x530, length 890 according to selection • PANEL COLOUR Beige RAL 9002

 Open the catalog to page 5
COMPO Series-6

GENERAL TECHNICAL SPECIFICATIONSCID 845439• FANS DD 10-10 TAC 3/4 (CID: 720056)• AIRFLOW 500 to 3000 m3/h • CROSS-SECTION 630 X 630, length 890 mm according to selection • PANEL COLOUR White RAL 9002 0. Available fan pressure for the 4-row heating battery 1. Total noise pressure in dBA radiated in free field at 3 m over system curve 1000 m3/h at 150 Pa 2. Water battery (2 rows) 80/60, air -10°C, 50% RH 3. Water battery (4 rows) 70/50, air -10°C, 50% RH 4. Water battery (4 rows, condensation), condensation temp. 45°C, air -10°C, 50% RH 6. R410a battery, evaporation temp. 5°C, air 25°C, 50% RH...

 Open the catalog to page 6
COMPO Series-7

Fan curve DD 11-11 TAC 1/1 GENERAL TECHNICAL SPECIFICATIONS CID 845440 • CROSS-SECTION 890 x 890, length 890 according to selection • PANEL COLOUR Beige RAL 9002 0. Available fan pressure for the 4-row heating battery 1. Total noise pressure in dBA radiated in free field at 3 m over system curve 1000 m3/h at 150 Pa 2. Water battery (2 rows) 80/60, air -10°C, 50% RH 3. Water battery (4 rows) 70/50, air -10°C, 50% RH 4. Water battery (4 rows, condensation), condensation temp. 45°C, air -10°C, 50% RH 6. R410a battery, evaporation temp. 5°C, air 25°C, 50% RH

 Open the catalog to page 7
COMPO Series-8

GENERAL TECHNICAL SPECIFICATIONS CID 845441 • CROSS-SECTION 630 X 890, length 890 mm according to selection • THERMAL PROTECTION D10A/AC3/10kA • TEMPERATURES -20° to 55°C • PANEL COLOUR Beige RAL 9002 0. Available fan pressure for the 4-row heating battery 1. Total noise pressure in dBA radiated in free field at 3 m over system curve 1000 m3/h at 150 Pa 2. Water battery (2 rows) 80/60, air -10°C, 50% RH 3. Water battery (4 rows) 70/50, air -10°C, 50% RH 4. Water battery (4 rows, condensation), condensation temp. 45°C, air -10°C, 50% RH 6. R410a battery, evaporation temp. 5°C, air 25°C, 50% RH...

 Open the catalog to page 8
COMPO Series-9

COMPO SERIES GENERAL TECHNICAL SPECIFICATIONS CID 845442 0. Available fan pressure for the 4-row heating battery 1. Total noise pressure in dBA radiated in free field at 3 m over system curve 1000 m3/h at 150 Pa 2. Water battery (2 rows) 80/60, air -10°C, 50% RH 3. Water battery (4 rows) 70/50, air -10°C, 50% RH 4. Water battery (4 rows, condensation), condensation temp. 45°C, air -10°C, 50% RH 5. Water battery 7/12, air 25°C, 50% RH 6. R410a battery, evaporation temp. 5°C, air 25°C, 50% RH • CROSS-SECTION 630 x 1430, length 890 according to selection • THERMAL PROTECTION D20A/AC3/10kA (2 fans)...

 Open the catalog to page 9
COMPO Series-10

GENERAL TECHNICAL SPECIFICATIONS CID 845443 • CROSS-SECTION 340 X 890, length 890 mm according to selection • THERMAL PROTECTION D10A/AC3/10kA • TEMPERATURES -20° to 55°C • PANEL COLOUR Beige RAL 9002 0. Available fan pressure for the 4-row heating battery 1. Total noise pressure in dBA radiated in free field at 3 m over system curve 1000 m3/h at 150 Pa 2. Water battery (2 rows) 80/60, air -10°C, 50% RH 3. Water battery (4 rows) 70/50, air -10°C, 50% RH 4. Water battery (4 rows, condensation), condensation temp. 45°C, air -10°C, 50% RH 6. R410a battery, evaporation temp. 5°C, air 25°C, 50% RH...

 Open the catalog to page 10
COMPO Series-11

COMPO SERIES GENERAL TECHNICAL SPECIFICATIONSCID 845444 • FANS DP 9-7 TH TAC 1/1 (CID: 720059) 0. Available fan pressure for the 4-row heating battery 1. Total noise pressure in dBA radiated in free field at 3 m over system curve 1000 m3/h at 150 Pa 2. Water battery (2 rows) 80/60, air -10°C, 50% RH 3. Water battery (4 rows) 70/50, air -10°C, 50% RH 4. Water battery (4 rows, condensation), condensation temp. 45°C, air -10°C, 50% RH 5. Water battery 7/12, air 25°C, 50% RH 6. R410a battery, evaporation temp. 5°C, air 25°C, 50% RH • CROSS-SECTION 430 x 890, length 890 according to selection • THERMAL...

 Open the catalog to page 11

All P. LEMMENS COMPANY catalogs and technical brochures

  1. GLOBAL PX

    23  Pages

  2. GLOBAL LP OUT

    24  Pages

  3. GLOBAL RX TOP

    32  Pages

  4. GLOBAL RX

    44  Pages

  5. Aira

    4  Pages

  6. CUBUS

    4  Pages

  7. GLOBAL PX/RX/LP

    64  Pages

  8. AC series

    4  Pages

  9. AE series

    4  Pages

  10. AIRA series

    4  Pages

  11. BA series

    2  Pages

  12. CUBUS series

    4  Pages

  13. ES series

    2  Pages

  14. LCO series

    6  Pages

  15. REC X series

    4  Pages

  16. TV series

    4  Pages

  17. TAC series

    4  Pages

  18. COMPO series

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.