Description
QuietZone® Spiral Duct Liner is designed to enhance indoor environmental quality by absorbing noise and reducing heat loss or gain through duct walls. It features a cleanable surface with a black mat facing, making it easier to maintain using methods outlined by NAIMA. The product is resistant to bacterial and fungal growth due to an EPA-registered biocide.

Key Features
  • Outstanding thermal and acoustical performance.
  • Durable, cleanable surface.
  • Microbial growth resistance.

Product Applications and Limitations
The liner is not recommended for ducts exposed to temperatures exceeding 250°F internally or 150°F externally, kitchen or fume exhausts, or ducts conveying solids or corrosive gases. It should not be buried in concrete or installed near high-temperature equipment without protection.

Installation
Installation should follow the Owens Corning™ QuietZone® Spiral Duct Liner manual. Coatings with EPA-registered antimicrobials should be applied to edges and cuts as needed.

Technical Information
  • Maximum Temperature Limits: 250°F internal, 150°F external.
  • Maximum Air Velocity: 6,000 fpm.
  • Water Vapor Sorption: <3% by weight.
  • Mold, fungi, and bacteria resistance meets ASTM standards.
  • Surface Burning Characteristics: Flame Spread <25, Smoke Developed <50.

Standards and Compliance
The product complies with NFPA 90A/90B, ICC International Mechanical Code, and NYC MEA# 186-69. It meets ASTM standards for fungi and bacteria resistance.

Certifications and Sustainability
QuietZone® Spiral Duct Liner contains a minimum of 57% recycled glass content and is certified under the GREENGUARD Indoor Air Quality Certification Program.

Product Availability
Available in thicknesses of 1" and 1½" with dimensions of 48" x 120". Thermal performance at 75°F mean temperature is R-value 4.3 for 1" and 6.5 for 1½" thickness.

Acoustical Performance
Sound absorption coefficients vary by thickness and frequency, with NRC values of 0.70 for 1" and 0.85 for 1½".

Disclaimer
Technical information is provided without charge or obligation and is subject to recipient's risk. Owens Corning is not liable for data accuracy or reliability under specific conditions of use.
See more

Catalog excerpts

QuietZone® Spiral Duct Liner-1

QuietZone® Spiral Duct Liner Product Data Sheet Typical Physical Properties Property Test Method Maximum Temperature Limits Internal External Water Vapor Sorption Mold Growth Meets Requirements Fungi Resistance Meets Requirements Bacteria Resistance Meets Requirements Surface Burning Characteristics Flame Spread Smoke Developed Description QuietZone® Spiral Duct Liner enhances indoor environmental quality by absorbing noise and by lowering heat loss or gain through duct walls. Key Features • Outstanding thermal and acoustical performance. • Cleanable surface with a black mat facing that provides a smooth, durable surface making it easier to clean the duct liners using methods and equipment described in North American Insulation Manufacturers Association (NAIMA) Publication AH122, Cleaning Fibrous Glass Insulated Duct Systems: Recommended Practice. • Bacterial and fungal growth resistant with an EPA registered biocide that protects the airstream surface from microbial growth. Product Applications Limitations QuietZone® Spiral Duct Liner is not recommended for the following applications: 1. The surface burning characteristics of these products have been determined in accordance with UL 723. This standard should be used to measure and describe the properties of materials, products or assemblies in response to heat and flame under controlled laboratory conditions and should not be used to describe or appraise the fire hazard or fire risk of materials, products or assemblies under actual fire conditions. However, results of this test may be used as elements of a fire risk assessment which takes into account all of the factors which are pertinent to an assessment of the fire hazard of a particular end use. Values are reported to the nearest 5 rating. ASTM E 84, UL 723, and NFPA 255 are considered by most officials to be synonymous surface burning test methods. A. Ducts which will be subjected to operating temperatures exceeding 250°F (inside surface). B. Ducts which will be subjected to temperatures exceeding 150°F on the outside surface. C. Kitchen or fume exhaust ducts or to convey solids or corrosive gases. D. Burying in concrete or buried below grade. E. Installation immediately adjacent to high-temperature electric heating coils without radiation protection and to equipment such as evaporative coolers, humidifiers, cooling coils and outside intakes. F. With coal or wood-fueled equipment, or with equipment of any type which does not include automatic maximum temperature controls. G. Ducts which will be subject to liquid water, liner should be protected with a sheet metal sleeve and drip pan adjacent. H. Inside fire damper sleeves. I. When duct systems run through unconditioned space and are used for cooling only (when heating is from another source), register openings must be tightly sealed to prevent accumulation of water vapor in the duct system during the heating season. Installation Refer to Owens Corning™ QuietZone® Spiral Duct Liner installation manual for proper installation of the liner. When required, duct liner coating should be designed for HVAC interior ductwork that contains an EPA-registered antimicrobial (biocide). The coating is applied to the edges, fabrication cuts, and repair of airstream surface when needed. Technical Information Tips to Avoid Mold Growth in Ducts Mold in duct systems occurs when moisture comes into

 Open the catalog to page 1
QuietZone® Spiral Duct Liner-2

QuietZone® Spiral Duct Liner Product Data Sheet contact with dirt or dust collected on the duct system surfaces. Proper filters will minimize the collection of dust and dirt, but care needs to be exercised to prevent water formation in the duct. A properly sized, installed and operated air conditioning unit will minimize the likelihood of water formation. The system must be maintained and operated to insure that sufficient dehumidification is occurring and that filters are installed and changed as recommended by the equipment manufacturer. Standards, Codes Compliance • National Fire Protection...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.