QuietZone® Spiral Duct Liner
2Pages

{{requestButtons}}

Catalog excerpts

QuietZone® Spiral Duct Liner - 1

QuietZone® Spiral Duct Liner Product Data Sheet Typical Physical Properties Property Test Method Maximum Temperature Limits Internal External Water Vapor Sorption Mold Growth Meets Requirements Fungi Resistance Meets Requirements Bacteria Resistance Meets Requirements Surface Burning Characteristics Flame Spread Smoke Developed Description QuietZone® Spiral Duct Liner enhances indoor environmental quality by absorbing noise and by lowering heat loss or gain through duct walls. Key Features • Outstanding thermal and acoustical performance. • Cleanable surface with a black mat facing that provides a smooth, durable surface making it easier to clean the duct liners using methods and equipment described in North American Insulation Manufacturers Association (NAIMA) Publication AH122, Cleaning Fibrous Glass Insulated Duct Systems: Recommended Practice. • Bacterial and fungal growth resistant with an EPA registered biocide that protects the airstream surface from microbial growth. Product Applications Limitations QuietZone® Spiral Duct Liner is not recommended for the following applications: 1. The surface burning characteristics of these products have been determined in accordance with UL 723. This standard should be used to measure and describe the properties of materials, products or assemblies in response to heat and flame under controlled laboratory conditions and should not be used to describe or appraise the fire hazard or fire risk of materials, products or assemblies under actual fire conditions. However, results of this test may be used as elements of a fire risk assessment which takes into account all of the factors which are pertinent to an assessment of the fire hazard of a particular end use. Values are reported to the nearest 5 rating. ASTM E 84, UL 723, and NFPA 255 are considered by most officials to be synonymous surface burning test methods. A. Ducts which will be subjected to operating temperatures exceeding 250°F (inside surface). B. Ducts which will be subjected to temperatures exceeding 150°F on the outside surface. C. Kitchen or fume exhaust ducts or to convey solids or corrosive gases. D. Burying in concrete or buried below grade. E. Installation immediately adjacent to high-temperature electric heating coils without radiation protection and to equipment such as evaporative coolers, humidifiers, cooling coils and outside intakes. F. With coal or wood-fueled equipment, or with equipment of any type which does not include automatic maximum temperature controls. G. Ducts which will be subject to liquid water, liner should be protected with a sheet metal sleeve and drip pan adjacent. H. Inside fire damper sleeves. I. When duct systems run through unconditioned space and are used for cooling only (when heating is from another source), register openings must be tightly sealed to prevent accumulation of water vapor in the duct system during the heating season. Installation Refer to Owens Corning™ QuietZone® Spiral Duct Liner installation manual for proper installation of the liner. When required, duct liner coating should be designed for HVAC interior ductwork that contains an EPA-registered antimicrobial (biocide). The coating is applied to the edges, fabrication cuts, and repair of airstream surface when needed. Technical Information Tips to Avoid Mold Growth in Ducts Mold in duct systems occurs when moisture comes into

Open the catalog to page 1
QuietZone® Spiral Duct Liner - 2

QuietZone® Spiral Duct Liner Product Data Sheet contact with dirt or dust collected on the duct system surfaces. Proper filters will minimize the collection of dust and dirt, but care needs to be exercised to prevent water formation in the duct. A properly sized, installed and operated air conditioning unit will minimize the likelihood of water formation. The system must be maintained and operated to insure that sufficient dehumidification is occurring and that filters are installed and changed as recommended by the equipment manufacturer. Standards, Codes Compliance • National Fire...

Open the catalog to page 2

All Owens Corning Insulation catalogs and technical brochures

  1. Air handling

    8 Pages

Archived catalogs

  1. FOAMULAR

    2 Pages

  2. Foamular

    16 Pages