10024336-MATEENBAR-Fiberglas-Rebar-Bent-Bar-PDS
2Pages

{{requestButtons}}

Catalog excerpts

10024336-MATEENBAR-Fiberglas-Rebar-Bent-Bar-PDS - 1

MATEENBAR™ FIBERGLAS™ REBAR BENT BAR Product Benefits Owens Corning® MATEENBAR™ Fiberglas™ Rebar Bent Bar is designed as a structural, corrosion resistant, lightweight, electromagnetically neutral internal reinforcement solution for concrete. • Makes concrete structures durable in aggressive environments. • Provides longer service life compared with structures reinforced with steel. • Complies with ASTM D7957 and CSA S807 material standards for Solid Round Fiberglass Rebar (also known as FRP, GFRP or composite rebar) for Concrete Reinforcement. Extended Service Life of Structures • MATEENBAR™ Fiberglas™ Rebar is a proven corrosion resistant reinforcement designed to provide structures with longer service life compared with structures reinforced with steel. Increased Productivity • Four times lighter than steel, Owens Corning® MATEENBAR™ Fiberglas™ Rebar can be installed faster with less labor.* Exceptional Strength • Ultimate tensile strength of MATEENBAR™ Fiberglas™ Rebar is twice the yield strength of steel.* * Based on sample testing of #5 rebar, GFRP exhibits linear-elastic behavior up to ultimate tensile strength. Owens Corning® MATEENBAR™ Fiberglas™ Rebar is designed to reinforce concrete in: Transportation Structures • Bridge decks High Voltage & Electromagnetic Fields • Traffic barriers • Light & heavy rail • Wall panels • Civil roadways • Soft-eye for tunnels Owens Corning® MATEENBAR™ Fiberglas™ Rebar bent bars are available in North America in the following diameters: #2 (M6), #3 (M10), #4 (M13), #5 (M16), #6 (M19), #7 (M22), and #8 (M25). Bent shapes can be fabricated for orders with detailed bar lists – see our MATEENBAR™ FIBERGLAS™ REBAR Bent Bar Detailing Guide. Product Data Sheet

Open the catalog to page 1
10024336-MATEENBAR-Fiberglas-Rebar-Bent-Bar-PDS - 2

Straight Portion of Bent Bars, Technical Characteristics (ASTM D7957, CSA S807) NOMINAL DIAMETER NOMINAL CROSS SECTIONAL AREA UNIT WEIGHT/ LENGTH GUARANTEED ULTIMATE TENSILE FORCE* GUARANTEED ULTIMATE TENSILE STRENGTH* MEAN ULTIMATE TENSILE STRAIN* MEAN TENSILE MODULUS OF ELASTICITY* FIBER MASS CONTENT* MOISTURE ABSORPTION TO SATURATION AT 50°C [122°F]** MEAN GLASS TRANSITION TEMPERATURE (DSC)* MEAN APPARENT HORIZONTAL SHEAR* MEAN TRANSVERSE SHEAR STRENGTH** Primary materials: E-CR glass and vinyl ester resin. Bond strength exceeds ASTM D7957 requirement. Bond-dependent coefficient K b...

Open the catalog to page 2

All Owens Corning Insulation catalogs and technical brochures

  1. Air handling

    8 Pages

Archived catalogs

  1. FOAMULAR

    2 Pages

  2. Foamular

    16 Pages