1. Catalogs
  2. O.ERRE
  3. CS EX-ATEX

CS EX-ATEX

CS EX-ATEX

CS EX-ATEX

Product catalog summary
Overview: The document provides technical specifications and applications for CS EX-ATEX explosion-proof centrifugal fans, designed for environments with high explosion risks due to the presence of gases, vapors, or inflammable steam. These fans comply with the ATEX Directive 84/9/EEC and are certified by the CESI institute.
Specifications:
  • Certified for zones 1 and 2, suitable for commercial and industrial environments.
  • Fan group II, category 2 for gases, construction safety C, with a maximum surface temperature of T3 (200°C).
  • Steel plated frame with epoxy-based anticorrosive paint and aluminum centrifugal impeller.
  • Ball bearing class F insulation motor with IP55 protection.
  • Maximum temperature of extracted air: 60°C.
  • Models CS 350, 360, 370, and 380 come with a rigid base support for easier installation.
  • Standard impeller housing position is CCW 270, with other positions available upon request.
  • Reference standards include EN 13463-1, EN 13463-5, and EN 14986.
Applications:
  • Suitable for wall mounting in industrial, civil, and commercial applications such as shops, workshops, sports facilities, supermarkets, shopping centers, warehouses, factories, and machinery.
Technical Data:
  • Various models (CS 310 to CS 380) with different dimensions, motor specifications, flow rates, and pressures.
  • Flow rates range from 500 m3/h to 9100 m3/h, with corresponding pressures and power requirements.
  • Motors are available in single-phase and three-phase configurations, with a standard speed of 1400 RPM.
Flow Charts: The document includes flow charts for each model, illustrating the relationship between flow rate and pressure.
Accessories: Accessories suitable for installation outside of the EX ATEX area are mentioned, with further details available on page 85.
See more

Catalog excerpts

CS EX-ATEX-1

CS EX-ATEX EXPLOSION PROOF FANS EX-ATEX Explosion Proof Certified Centrifugal fans to extract air and fumes through medium/long sized ducts in compliance with ATEX Directive 84/9/EEC effective from July 1st 2003 in EU. • Suitable for applications in commercial and industrial environments where the risk of explosion is high and where the surrounding atmosphere contains gas, vapours or highly inflammable steam; • The whole product and not just the electrical parts, has been certified by CESI institute with CESI n°03 ATEX 250 certificate; • Fan group II, cat. 2 for gases, construction safety C, max surface temp. T3 (200°C); • Classified for zones 1 and 2; • This approval has required specific safety tests and proper examinations on products to verify how the adopted solutions have satisfied the essential Directive requirements; • Steel plated frame protected by an epoxy-based anticorrosive paint and aluminium centrifugal impeller statically and dynamically balanced; • Ball bearing class F insulation motor IP55 protected; • Max temperature of extracted air: 60°C; • Models CS 350, 360, 370 and 380: mounted on rigid base support to make installation easier; • Standard product supplied with impeller housing position CCW 270, different positions available on request (see table on page 89); • Reference Standards: EN 13463-1: EN 13463-5; EN 14986. POSITIONING - Wall mounting ENVIRONMENTS APPLICATION Suitable for Industrial, civil and commercial application where the risk of explosion is high. - Shops - Workshops - Sports facilities - Supermarkets and shopping centers - Warehouse - Factories - Machinery TECHNICAL DATA Model Frequency Flow rate Max press. Max press. Power Nom. Curr. (A) IP Motor (Hz) CS 310 4M Ex-ATEX 0032500 II 2G c T4 Single phase 4 CS 320 4M Ex-ATEX 0032700 II 2G c T4 Single phase 4 CS 320 4T Ex-ATEX 0032800 II 2G c T4 Three phase 4 CS 330 4T Ex-ATEX 0032900 II 2G c T4 Three phase 4 CS 350 4T Ex-ATEX 0033000 II 2G c T4 Three phase 4 CS 360 4T Ex-ATEX 0032200 II 2G c T4 Three phase 4 CS 380 4T EX-ATEX 0033800 II 2G c T4 Three phase 4

 Open the catalog to page 1
CS EX-ATEX-2

FLOW CHARTS • CS 320 4M-T EX-ATEX ACCESSORIES (SUITABLE FOR INSTALLATION OUTSIDE OF THE EX ATEX AREA) SEE PA

 Open the catalog to page 2

All O.ERRE catalogs and technical brochures

  1. EASY

    2  Pages

  2. GHOST

    2  Pages

  3. MIAMI

    1  Page

  4. IN AXIAL FAN

    3  Pages

  5. EB EX-ATEX

    2  Pages

  6. AIRPOWER ABS

    1  Page

  7. FIRENZE

    1  Page

  8. PHONNY MURO

    1  Page

  9. PHONNY TUBO

    1  Page

  10. SMART

    2  Pages

  11. VENTILOR

    1  Page

  12. SILENTE

    2  Pages

  13. HEV

    1  Page

  14. TEMPERO line

    52  Pages

  15. SYSTEMA

    1  Page

  16. T° Control

    48  Pages

  17. Industry

    92  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.