Technical Specifications:
The Pellematic Condens boilers are available in models ranging from 10 to 18 kW. They have a high energy efficiency class of A++ and an energy efficiency index (EEI) ranging from 131.89 to 135.13. The boilers operate with a seasonal space heating energy efficiency of 93-94%. The efficiency in condensing mode (HHV) ranges from 97.7% to 99.5%, and in standard heating mode, it ranges from 95% to 98.7%.

Water and Flue Gas Specifications:
The water capacity is 72 liters with a flow/return connection of 1 inch. The boilers have a maximum operating pressure of 3 Bar and a test pressure of 4.6 Bar. Flue gas temperatures in condensation mode range from 38°C to 80°C, while in standard heating mode, they range from 60°C to 90°C. The flue gas volume varies depending on the mode and load, with specific values provided for each model.

Fuel and Combustion:
The boilers use pellets made of 100% natural wood, conforming to EN ISO 17225–2, class A1. The calorific value is approximately 16.5 MJ/kg or 4.6 kWh/kg, with a bulk density of 600 kg/m3. The water content is 10% by weight, and ash content is 0.7% by weight.

Dimensions and Installation:
The overall dimensions of the boilers are consistent across models, with a depth of 724 mm, height of 1408 mm, and width of 732 mm. The minimum clearance dimensions for installation are specified to ensure proper setup and operation. The minimum ceiling height required is 1850 mm.

Electrical Components:
The boilers require a connection value of 230 VAC, 50Hz, 16A. Various components such as the main drive, standby power, drive motor, flue gas fan, electrical ignition, and cleaning motor have specific power requirements.

Additional Notes:
It is important to check door dimensions before installation to ensure the boiler can be brought into the building without dismantling components. Compliance with local legislation regarding flue gas tube clearance is mandatory.
See more

Catalog excerpts

Technical data PELLEMATIC® Condens-1

Technical data PELLEMATIC® Condens 10 – 18 kW

 Open the catalog to page 1
Technical data PELLEMATIC® Condens-4

Notes on bringing the unit into the building Before bringing the unit into the building, check the dimensions of all doors to ensure that the boiler has sufficient clearance and can be set up properly. Minimum door width — max. unit dimension Boiler size

 Open the catalog to page 4
Technical data PELLEMATIC® Condens-5

Boiler Weight Boiler size Weight of boiler packaged on pallet with wooden frame – kg Weight of boiler without casing, hopper and burner – kg Weight of boiler with casing, hopper and burnerr – kg Minimum clearance dimensions required Note: To install the heating system properly and ensure economical operation, you need to make sure that minimum clearance dimensions indicated below are observed when setting up the boiler. In addition, make sure that legislation in your country is complied with relating to the minimum clearance of the flue gas tube. a Min. clearance of flue gas connection from wall...

 Open the catalog to page 5
Technical data PELLEMATIC® Condens-6

Author OkoFEN Forschungs- &. EntwicklungsgesmbH A-4133 Niederkappel, Gewerbepark1 Tel.: +43 (0) 72 86/74 50 Fax.: +43 (0) 72 86 / 74 50 - 10 E-Mai|: oekofen@pe||etsheizung.at © by OkoFEN Forschungs- und EntwicklungsgesmbH www.oekofen.com Subject to modifcations

 Open the catalog to page 6
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.