PELLEMATIC PE(S) 10 — 56 kW-1

Technical data PELLEMATIC® PE(S) 10 — 56 kW

 Open the catalog to page 1
PELLEMATIC PE(S) 10 — 56 kW-2

Technical data Here you can find the technical data according to the boiler type. PE 08 Boiler – Type Boiler efficiency rated power [%] Boiler efficiency partial power [%] Water area Water capacity [litres] Water supply/return Ø [inch] Water resistance at 10K [mBar] Water resistance at 20K [mBar] Boiler input temperature minimum [°C] Operating pressure maximum [Bar] Flue gas area (Flue gas = F.g.) 800–1100 Fire vault temperature [°C] Need of draught rated power [mBar] Need of draught partial load [mBar] Flue gas temperature rated power [°C] Flue gas temperature partial load [°C] F.g. volume rated...

 Open the catalog to page 2
PELLEMATIC PE(S) 10 — 56 kW-3

Boiler – Type Chimney construction Steel or ceramic lined, damp resistant Pellets made of 100% natural wood according to EN 14961–2, class A1 Colorific value [MJ/kg] Colorific value [kWh/kg] Bulk density [kg/m3] Water content [weight %] Weight Overall Weight packing included [kg] Boiler Body Weight [kg] Electrical Components Connection value Suction Turbine [W] Combustion Air Blower [W] Motor Burner plate cleaning system [W] Flame Return Gate [W] Emissions acc. to test reports Reference 10% O2 dry (EN303-5) CO rated power [mg/m3]

 Open the catalog to page 3
PELLEMATIC PE(S) 10 — 56 kW-4

Dust rated power [mg/m3] Dust rated power [mg/m3] Dust rated power [mg/m3] Boiler – Type The data are values of the test measurement and can vary from locally measured values WB Federal Institute of Agricultural Engineering Wieselburg Adress: A-3250 Wieselburg, Rottenhauserstraße 1; Tel.: +43–7416–52175–0 Note: Test reports are available at ÖkoFEN Technical data PELLEMATIC®PE(S) 10 — 56 kW

 Open the catalog to page 4
PELLEMATIC PE(S) 10 — 56 kW-5

Required space Dimensions in mm B – overall width of boiler C – width of boiler casing H – height of boiler casing D – height of pellet suction system F – height of suction system filling unit T – depth of boiler casing V – depth of burner casing E – flue gas tube connection height R – diameter of flue gas tube Boiler Weight Dimensions in kg Overall Weight packing included Overall Weight Boiler Body Weight Minimum clearance dimensions required Note: To install the heating system properly and ensure economical operation, you need to make sure that minimum clearance dimensions indicated below are...

 Open the catalog to page 5