Catalog excerpts
Technical data PELLEMATIC® PE(S) 10 — 56 kW
Open the catalog to page 1Technical data Here you can find the technical data according to the boiler type. PE 08 Boiler – Type Boiler efficiency rated power [%] Boiler efficiency partial power [%] Water area Water capacity [litres] Water supply/return Ø [inch] Water resistance at 10K [mBar] Water resistance at 20K [mBar] Boiler input temperature minimum [°C] Operating pressure maximum [Bar] Flue gas area (Flue gas = F.g.) 800–1100 Fire vault temperature [°C] Need of draught rated power [mBar] Need of draught partial load [mBar] Flue gas temperature rated power [°C] Flue gas temperature partial load [°C] F.g. volume...
Open the catalog to page 2Boiler – Type Chimney construction Steel or ceramic lined, damp resistant Pellets made of 100% natural wood according to EN 14961–2, class A1 Colorific value [MJ/kg] Colorific value [kWh/kg] Bulk density [kg/m3] Water content [weight %] Weight Overall Weight packing included [kg] Boiler Body Weight [kg] Electrical Components Connection value Suction Turbine [W] Combustion Air Blower [W] Motor Burner plate cleaning system [W] Flame Return Gate [W] Emissions acc. to test reports Reference 10% O2 dry (EN303-5) CO rated power [mg/m3]
Open the catalog to page 3Dust rated power [mg/m3] Dust rated power [mg/m3] Dust rated power [mg/m3] Boiler – Type The data are values of the test measurement and can vary from locally measured values WB Federal Institute of Agricultural Engineering Wieselburg Adress: A-3250 Wieselburg, Rottenhauserstraße 1; Tel.: +43–7416–52175–0 Note: Test reports are available at ÖkoFEN Technical data PELLEMATIC®PE(S) 10 — 56 kW
Open the catalog to page 4Required space Dimensions in mm B – overall width of boiler C – width of boiler casing H – height of boiler casing D – height of pellet suction system F – height of suction system filling unit T – depth of boiler casing V – depth of burner casing E – flue gas tube connection height R – diameter of flue gas tube Boiler Weight Dimensions in kg Overall Weight packing included Overall Weight Boiler Body Weight Minimum clearance dimensions required Note: To install the heating system properly and ensure economical operation, you need to make sure that minimum clearance dimensions indicated below...
Open the catalog to page 5All ÖkoFEN catalogs and technical brochures
-
Technical data PELLEMATIC®
6 Pages
-
PELLEMATIC® PE(S) 10 — 56 kW
4 Pages
-
PELLEMATIC® SmartXS
38 Pages
-
Pellematic Compact
4 Pages
-
PELLEMATIC Smart 4 — 14 kW
9 Pages