PELLEMATIC Condens 10 — 18 kW
6Pages

{{requestButtons}}

Catalog excerpts

PELLEMATIC Condens 10 — 18 kW - 2

Technical data Pellematic Condens Here you can find the technical data according to the boiler type. Boiler – Type Boiler eff. rated power condensation mode [%] Boiler eff. rated power standard heat. mode [%] Boiler eff. partial power condensation mode [%] Boiler eff. partial power standard heat. mode [%] Water capacity [litres] Feed / return connection IG Ø [inch] Feed / return connection IG Ø [DN] Water resistance at 10K [mBar] Water resistance at 20K [mBar] Boiler temperature [°C] Minimum boiler temperature [°C] Minimum return (boiler inlet) temperature [°C] Operating pressure maximum...

Open the catalog to page 2
PELLEMATIC Condens 10 — 18 kW - 3

Boiler – Type F.g. volume partial load at AGT standard heating mode [m3/h] Flue gas tube diameter (at the boiler) [mm] Chimney diameter Chimney construction qualified for condensing, solid fuel, damp resistant, N1 or P1 (depending on chimney calculation), connection pipe at least 20Pa overpressure-tight Pellets made of 100% natural wood according to EN 14961–2, class A1 Colorific value [MJ/kg] Colorific value [kWh/kg] Bulk density [kg/m3] Water content [weight %] Overall Weight [kg] Electrical Components Connection value Main Drive [W] Standby power [W] Drive Motor [W] Emissions acc. to...

Open the catalog to page 3
PELLEMATIC Condens 10 — 18 kW - 4

Boiler – Type OGC rated power standard heat. mode [mg/m3] OGC partial load condensation mode [mg/m3] OGC partial load standard heating mode [mg/m3] Dust rated power condensation mode [mg/m3] Dust rated power standard heat. mode [mg/m3] CO rated power condensation mode [mg/m3] CO rated power standard heating mode [mg/m3] CO partial load condensation mode [mg/m3] CO partial load standard heating mode [mg/m3] OGC rated power condensation mode [mg/m3] OGC rated power standard heat. mode [mg/m3] OGC partial load condensation mode [mg/m3] OGC partial load standard heating mode [mg/m3] Dust rated...

Open the catalog to page 4
PELLEMATIC Condens 10 — 18 kW - 5

Date of issue: 21.08.2014 Test reports are available at: www.oekofen.com Notes on bringing the unit into the building Before bringing the unit into the building, check the dimensions of all doors to ensure that the boiler has sufficient clearance and can be set up properly. Minimum door width — max. unit dimension PE Condens Dismantling of components not necessary Dismantle casing

Open the catalog to page 5
PELLEMATIC Condens 10 — 18 kW - 6

Pellematic Condens 10–18 T – Depth of boiler casing H – Height of boiler casing B – Overall width of pellet boiler E – Height of flue gas tube connection Boiler Weight Boiler size Weight of boiler packaged on pallet with wooden frame – kg Weight of boiler with casing, hopper and burnerr – kg Weight of boiler without casing, hopper and burner – kg Minimum clearance dimensions required Note: To install the heating system properly and ensure economical operation, you need to make sure that minimum clearance dimensions indicated below are observed when setting up the boiler. In addition, make...

Open the catalog to page 6