Product catalog summary
Technical Specifications:
The Pellematic Condens series includes models with boiler-rated power ranging from 10 to 18 kW. The efficiency in condensation mode is between 105.5% and 107.3%, while in standard heating mode, it ranges from 95% to 98.7%. The water capacity is 72 liters, with a feed/return connection diameter of 1 inch (DN 25). The operating pressure is a maximum of 3 Bar, with a test pressure of 4.6 Bar.

Flue Gas Specifications:
The combustion chamber temperature ranges from 400 to 900°C. Flue gas temperatures in condensation mode range from 38 to 80°C, and in standard heating mode from 60 to 90°C. The flue gas volume varies with power and mode, with specific values provided for each model.

Fuel and Emissions:
The boiler uses pellets made of 100% natural wood, with a calorific value of 16.5 to 19 MJ/kg. Emissions are detailed for CO, OGC, and dust, with values provided for both rated and partial loads in condensation and standard heating modes.

Dimensions and Installation:
The boiler dimensions are 724 mm in depth, 1408 mm in height, and 732 mm in width. Minimum clearance dimensions are specified for proper installation, including a minimum ceiling height of 2050 mm. The weight of the boiler varies depending on the configuration, with the packaged weight on a pallet being 340 kg.

Electrical Components:
The connection value is 230 VAC, 50Hz, 16A, with various components such as the main drive, standby power, and flue gas fan having specific power requirements.

Notes:
Ensure that the dimensions of doors are checked before bringing the unit into the building. Compliance with local legislation regarding flue gas tube clearance is necessary.
See more

Catalog excerpts

PELLEMATIC Condens 10 — 18 kW-2

Technical data Pellematic Condens Here you can find the technical data according to the boiler type. Boiler – Type Boiler eff. rated power condensation mode [%] Boiler eff. rated power standard heat. mode [%] Boiler eff. partial power condensation mode [%] Boiler eff. partial power standard heat. mode [%] Water capacity [litres] Feed / return connection IG Ø [inch] Feed / return connection IG Ø [DN] Water resistance at 10K [mBar] Water resistance at 20K [mBar] Boiler temperature [°C] Minimum boiler temperature [°C] Minimum return (boiler inlet) temperature [°C] Operating pressure maximum [Bar]...

 Open the catalog to page 2
PELLEMATIC Condens 10 — 18 kW-3

Boiler – Type F.g. volume partial load at AGT standard heating mode [m3/h] Flue gas tube diameter (at the boiler) [mm] Chimney diameter Chimney construction qualified for condensing, solid fuel, damp resistant, N1 or P1 (depending on chimney calculation), connection pipe at least 20Pa overpressure-tight Pellets made of 100% natural wood according to EN 14961–2, class A1 Colorific value [MJ/kg] Colorific value [kWh/kg] Bulk density [kg/m3] Water content [weight %] Overall Weight [kg] Electrical Components Connection value Main Drive [W] Standby power [W] Drive Motor [W] Emissions acc. to test...

 Open the catalog to page 3
PELLEMATIC Condens 10 — 18 kW-4

Boiler – Type OGC rated power standard heat. mode [mg/m3] OGC partial load condensation mode [mg/m3] OGC partial load standard heating mode [mg/m3] Dust rated power condensation mode [mg/m3] Dust rated power standard heat. mode [mg/m3] CO rated power condensation mode [mg/m3] CO rated power standard heating mode [mg/m3] CO partial load condensation mode [mg/m3] CO partial load standard heating mode [mg/m3] OGC rated power condensation mode [mg/m3] OGC rated power standard heat. mode [mg/m3] OGC partial load condensation mode [mg/m3] OGC partial load standard heating mode [mg/m3] Dust rated power...

 Open the catalog to page 4
PELLEMATIC Condens 10 — 18 kW-5

Date of issue: 21.08.2014 Test reports are available at: www.oekofen.com Notes on bringing the unit into the building Before bringing the unit into the building, check the dimensions of all doors to ensure that the boiler has sufficient clearance and can be set up properly. Minimum door width — max. unit dimension PE Condens Dismantling of components not necessary Dismantle casing

 Open the catalog to page 5
PELLEMATIC Condens 10 — 18 kW-6

Pellematic Condens 10–18 T – Depth of boiler casing H – Height of boiler casing B – Overall width of pellet boiler E – Height of flue gas tube connection Boiler Weight Boiler size Weight of boiler packaged on pallet with wooden frame – kg Weight of boiler with casing, hopper and burnerr – kg Weight of boiler without casing, hopper and burner – kg Minimum clearance dimensions required Note: To install the heating system properly and ensure economical operation, you need to make sure that minimum clearance dimensions indicated below are observed when setting up the boiler. In addition, make sure...

 Open the catalog to page 6