Technical Specifications
The Pellematic Condens 10-18 kW is a condensing boiler with an energy efficiency class of A++ and an energy efficiency index (EEI) of 135. It operates automatically and uses pellets made of 100% natural wood as fuel, adhering to EN ISO 17225–2, class A1 standards. The boiler class is 5, and it does not support cogeneration or combined heating systems.

Performance Metrics
The boiler delivers useful heat ranging from 10 to 18 kW at nominal heat power and 3 to 5 kW at 30% of nominal heat power. Fuel efficiency at nominal heat output is 99%, and at 30% of nominal heat power, it is 96%. The boiler's rated power efficiency in standard heating mode ranges from 107.6% to 107.9%.

Emissions and Environmental Impact
Annual space heating emissions are kept low with PM < 40 mg/m3, OGC < 20 mg/m3, CO < 500 mg/m3, and NOx < 200 mg/m3. The auxiliary power consumption varies with the heat power, with a maximum of 47.5 W at nominal heat power and 14.9 W at 30% of nominal heat power.

Water and Flue Gas Specifications
The boiler has a water capacity of 72 liters and operates at a maximum pressure of 3 Bar. The flue gas system requires a chimney diameter of at least 130 mm and is designed for condensing, solid fuel, and damp resistance. The combustion chamber temperature ranges from 400 to 870°C.

Installation and Dimensions
The boiler casing dimensions are 724 mm in depth, 1408 mm in height, and 732 mm in width. The minimum clearance dimensions for installation must be observed to ensure proper operation and maintenance. The boiler's weight varies depending on the configuration, with a maximum packaged weight of 340 kg.

Electrical Components
The boiler operates on a 230 VAC, 50Hz, 16A connection. It includes components such as a main drive (40 W), standby power (7 W), drive motor (250/370 W), flue gas fan (9-120 W), and electrical ignition (250 W). The protection class is IP20.

Additional Notes
Before installation, ensure that door dimensions allow for the boiler's entry. Minimum door widths are specified, and dismantling of components may be necessary for narrower entries. Compliance with local legislation regarding flue gas tube clearance is mandatory.
See more

Catalog excerpts

Pellematic©  Condens 10 - 18 kW-2

© by ÖkoFEN Forschungs- und EntwicklungsgesmbH Subject to modifcatio

 Open the catalog to page 2
Pellematic©  Condens 10 - 18 kW-3

Technical data Information according to EU regulation 2015/1187 and 2015/1189 Model designation Manufacturer and contact details ÖkoFEN Forschungs- und Entwicklungs GmbH, Gewerbepark 1, 4133 Niederkappel, Austria Boiler class Heat-up mode Condensing boiler Solid fuel boiler with cogeneration system Combined heater Energy efficiency class Energy efficiency index (EEI) seasonal space heating energy efficiency in active mode ηson Seasonal space heating energy efficiency ηs (based on upper heating value) Delivered useful heat at nominal heat power Pn [kW] Delivered useful heat at 30 % of the nominal...

 Open the catalog to page 3
Pellematic©  Condens 10 - 18 kW-4

Model designation Annual space heating emissions PM [mg/m3] Auxiliary power consumption Auxiliary power consumption at nominal heat power elmax [W] Auxiliary power consumption at 30 % of nominal heat power elmin [W] Standby auxiliary power consumption PSB [W] Water area Cleaning connection [inch] Feed / return connection [inch] Feed / return connection Ø [DN] Water resistance at 10K [mbar] Water resistance at 20K [mbar] Boiler temperature [°C] Minimum boiler temperature [°C] Minimum return (boiler inlet) temperature Operating pressure maximum [Bar] Technical data

 Open the catalog to page 4
Pellematic©  Condens 10 - 18 kW-5

Model designation Flue gas area (Flue gas = F.g.) 1 Available delivery pressure of fan [mBar] Combustion chamber temperature [°C] Flue gas tube diameter (at the boiler) [mm] F.g. temp. rated power condensation mode [°C] F.g. temp. rated power standard heat. mode [°C] F.g. temp. partial load condensation mode [°C] F.g. temp. partial load standard heat. mode [°C] F.g. volume rated power at f.g.tem. condensation mode [kg/h] F.g. vol. rated power at f.g.tem. standard heating mode [kg/h] F.g. volume partial load at f.g. tem. condensation mode [kg/h] F.g. vol. partial load at f.g. tem. standard heating...

 Open the catalog to page 5
Pellematic©  Condens 10 - 18 kW-6

Model designation Rated heating power [kW] Firing thermal capacity nominal load [kW] CO2 volume concentration nominal load [%] Flue gas temperature for chimney calculation nominal load [° C] Required (+) or maximum (-) delivery pressure nominal load [Pa] Rated heating power partial load [kW] Rated thermal power partial load [kW] CO2 volume concentration partial load [%] Flue gas temperature for chimney calculation partial load [° C] Required (+) or maximum (-) delivery pressure partial load [Pa] Chimney calculation Flue gas iniertia current for chimney calculation nominal load [kg/s] Flue gas...

 Open the catalog to page 6
Pellematic©  Condens 10 - 18 kW-7

Model designation Electrical Components Connection value Protection class IP20 * Test bench value related to the lower calorific value of the fuel. Determined at continuous full-load ideal operation according to the measurement procedures in EN303-5. Practical values and seasonal efficiencies may deviate due to local conditions, fuel properties and individual modes of operation. The values do not refer to an individual boiler, but serve solely for comparison purposes between the different boiler types. Further technical data and results of the type test available on request from your ÖkoFEN contact....

 Open the catalog to page 7
Pellematic©  Condens 10 - 18 kW-8

2 Notes on bringing the unit into the building Notes on bringing the unit into the building Before bringing the unit into the building, check the dimensions of all doors to ensure that the boiler has sufficient clearance and can be set up properly. Minimum door width Technical data Dismantling of components not necessary Dismantle casing

 Open the catalog to page 8
Pellematic©  Condens 10 - 18 kW-9

2 Notes on bringing the unit into the building Boiler size Boiler size T – Depth of boiler casing – mm H – Height of boiler casing – mm B – Overall width of pellet boiler – mm E – Height of flue gas tube connection – mm F – Condensate drain connecting height – mm Boiler Weight Boiler size Weight of boiler packaged on pallet with wooden frame – kg Weight of boiler with casing, hopper and burner – kg Weight of boiler without casing, hopper and burner –

 Open the catalog to page 9
Pellematic©  Condens 10 - 18 kW-10

2 Notes on bringing the unit into the building Minimum clearance dimensions required To install the heating system properly and ensure economical operation, you need to make sure that minimum clearance dimensions indicated below are observed when setting up the boiler. In addition, make sure that legislation in your country is complied with relating to the minimum clearance of the flue gastube. Falling below the optimal distances means additional maintenance and cleaning work. The minimum distances must be strictly observed. The door only opens 45°. The indicated values must not fall below by...

 Open the catalog to page 10

All Oekofen catalogs and technical brochures

  1. zeroflame

    12  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.