Technical Specifications
  • Boiler Models: PE(S)K 12, 15, 20, 25, 32 kW
  • Boiler Rated Power: Ranges from 12 kW to 32 kW
  • Boiler Efficiency: Rated power efficiency ranges from 100% to 102.8%; partial load efficiency ranges from 98% to 102.3%
  • Water Capacity: 66 liters for models 12, 15, 20; 104 liters for models 25, 32
  • Operating Pressure: Maximum 3 Bar; Test pressure 4.6 Bar
  • Flue Gas Specifications: Fire vault temperature between 900 – 1100°C; Flue gas temperature at rated power/load between 30 – 40°C
  • Fuel Type: Pellets made of 100% natural wood, conforming to EN 14961–2, class A1
Physical and Electrical Specifications
  • Overall Weight: Ranges from 400 kg to 520 kg
  • Electrical Connection: 230 VAC, 50Hz, 16A
  • Electrical Components: Includes main drive, drive motor, suction turbine, combustion air blower, flue gas fan, electrical ignition, cleaning motor, and more
Emissions and Environmental Standards
  • O2 Content: Varies with power and load, ranging from 5.9% to 12.7%
  • CO Emissions: Rated power emissions range from 37 mg/m3 to 70 mg/m3; partial load emissions range from 147 mg/m3 to 202 mg/m3
  • NOX Emissions: Rated power emissions range from 65 mg/MJ to 72 mg/MJ
  • Dust Emissions: Rated power emissions range from 8 mg/m3 to 13 mg/m3
Compliance and Testing
  • Test reports available at ÖkoFEN
  • Complies with § 15a BVG Austria standards
See more

Catalog excerpts

Condensing boiler technology PE(S)K 12 — 32 kW-1

Technical data Condensing boiler technology PE(S)K 12 — 32 kW

 Open the catalog to page 1
Condensing boiler technology PE(S)K 12 — 32 kW-2

Technical data Pellematic Plus 1 Technical data Pellematic Plus PE(S)K 12 Boiler-rated power Boiler-partial load Boiler efficiency rated power Boiler efficiency partial power Water capacity Water supply/return dimensions Water supply/return dimensions Boiler temperature Boiler input temperature minimum Operating pressure maximum Test pressure Fire vault temperature Need of draught ra pow/pa load Flue gas temp ra pow/pa load F.g. volume rated power at f.g. tem. F.g. volume partial load at f.g. tem. F.g. volume rated power at AGT F.g. volume partial load at AGT Flue gas tube diameter Water area...

 Open the catalog to page 2
Condensing boiler technology PE(S)K 12 — 32 kW-3

Technical data Pellematic Plus Overall Weight packing included Overall Weight Boiler Body Weight Electrical Components Connection value Main Drive Drive Motor Suction Turbine Electrical Ignition Cleaning Motor Motor Burner plate cleaning system Flame Return Gate Emissions acc. to test reports Dust rated power Reference 13% O2 dry (Wieselburg) CO rated power Dust rated power

 Open the catalog to page 3
Condensing boiler technology PE(S)K 12 — 32 kW-4

Technical data Pellematic Plus Dust rated power The data are values of the test measurement and can vary from locally measured values. WB Federal Institute of Agricultural Engineering Wieselburg, A-3250 Wieselburg, Rottenhauserstraße 1; Test reports are available at ÖkoFEN Technical data Condensing boiler technologyPE(S)K 12 — 32 kW