Open the catalog to page 1OCHSNER Heat pumps
Open the catalog to page 2The choice of the right heating system for one’s own home is an important decision lasting for decades. The most important requirements for a heating system are: highest efficiency and thus lowest heating costs, comfort, operational safety, the best possible environment protection and long life. FOR THE ENVIRONMENT AND YOUR POCKET Heat pumps use the sun’s energy stored in the air, in water or the ground. Whoever decides on a heat pump not only saves CO2, but also has less to worry about increasing oil or gas prices or fear of problems in supply. YOUR DECISION TODAY ALREADY AFFECTS THE AMOUNT...
Open the catalog to page 3OCHSNER heating systems leave nothing to be desired WHY OCHSNER? GOLF MAXI PLUS GOLF MIDI PLUS OCHSNER IS ERP READY The ErP ready Symbol shows that OCHSNER is already meeting the requirements of obligatory labelling according to the Eco-Design Directive - valid from September 2015 onwards. OCHSNER’s cutting-edge technology in the heat pump and storage tank field is thus today providing solutions for tomorrow’s demands. Using OCHSNER heat pumps, you can achieve COPs which no other heating system can provide. COMPLETE PRODUCT RANGE – FOR HEATING, COOLING AND HOT WATER OCHSNER supplies a complete...
Open the catalog to page 4With the power of natural heat sources HOW A HEAT PUMP WORKS HOW DOES A HEAT PUMP WORK? The heat pump converts low temperature heat into heat of higher temperature – even in Winter at well below 0°C. This takes place in a closed circuit process through continuous changing of the aggregate condition of the refrigerant (1=evaporation, 2=compression, 3=condensation, 4=pressure release.) SELECT THE SYSTEM MOST SUITABLE FOR YOU OCHSNER stands for quality – this you can put your trust in. High investment in Research and Development, long-term experience and components of the highest value make this...
Open the catalog to page 5Energy supplies - direct from nature GROUND HEAT Due to the further development of the horizontal-split system technology, OCHSNER has made the use of air as a heat source economical as well. Air is available everywhere and in unlimited supply. The ground is a free-of-charge and abundant heat store and thus represents an ideal heat source. Using flat plate collectors, stored solar energy is mainly used – constantly and completely independent of the time of day or night. If installed correctly, sufficient source energy is available even in the deepest of winters. This system is also especially...
Open the catalog to page 6GROUND HEAT – BRINE If ground water is available at a reasonable depth and in sufficient quantity, one can reach the highest seasonal performance factors. A constant temperature of 8 – 12°C guarantees an optimum heating operation. Using this system, the ground heat is extracted by means of a brine circuit and then transferred to the heat pump. Two wells are necessary for this: a source well and a sink well. The sink well should be located at least 15 metres from the source well in the direction of the ground water flow. • f the garden area is sufficient, flat-plate collectors are the I least...
Open the catalog to page 7Overview of the OCHSNER High-tech heat pumps GOLF MIDI PLUS Heat pump for buildings with a small heat load GOLF MAXI PLUS Heat pump for heating and cooling - for buildings with a medium heat load STANDARD AND R Heat pump for heating and cooling - for buildings with a high heat load VHS-M HORZONTAL SPLIT EVAPORATOR Split outside unit for air/water heat pumps of the GMLW Series. Very quiet operation, highest efficiency and highest quality materials. Depending on the heat load, available either as single- or double-split evaporator in white or anthracite. Installation in combination with GOLF MIDI...
Open the catalog to page 8STORAGE TANKS Heating and hot water storage with heat pump separation tanks, heat pump hot water tanks or the fresh hot water heater Unifresh ELW 8 & ELW 12 Vertical Luft/Split-Wärmepumpe mit Invertertechnologie EUROPA MINI IWP(L) & MINI EWP Hot water heat pump for external storage tanks up to 500 litres, for heat sources air or ground. HIGH-CAPACITY HEAT PUMP For heating, active cooling and hot water heating in large-scale buildings in commerce, industry, large-volume dwellings and in the municipal sector. Up to 75°C flow temperature, high-temperature heat pumps up to 95°C flow temperature....
Open the catalog to page 9EFFICIENCY DOES NOT NEED TO BE HEARD GOLF MAXI PLUS ROOM TERMINAL VHS-M SPLIT EVAPORATOR
Open the catalog to page 10Outside air is the heat source that is always available in unlimited quantities. 20 years ago, OCHSNER was the first manufacturer to focus on efficient air/split technology. GMLW SERIES FOR THE QUIETEST OPERATION Experience, coupled with years of research and development make the OCHSNER GLMW Series the quietest air/split heat pumps on the market today. The GMLW Series is thus ideally suited both for new buildings and for retrofitting or bivalent operation systems. OVI-circuit for higher efficiency and increased limits of use Three expansion valves for optimum control of the refrigerant circuit...
Open the catalog to page 11The OCHSNER GMLW Series is distinguished by highest efficiency, long working life and especially silent running. VHS-M SPLIT EVAPORATOR Large fin clearances for absolute functional safety in Winter and optimised de-icing Low-noise, fully modulating energy-saving fan Injection group directly at the evaporator in order to prevent loss of performance Stainless steel cladding for long life
Open the catalog to page 12OCHSNER Horizontal Split System – GMLW Series HEAT SOURCE AIR USED WITH HIGH EFFICIENCY The high-efficiency horizontal split evaporator extracts the necessary amount of warmth from the outside air, whereby an optimised, automatic de-icing system keeps the evaporator, if required, ice-free without using much energy. Our horizontal split evaporators are manufactured in exclusive housings. Here, OCHSNER grants a 10-year guarantee against rusting through. Due to the sizing and optimum appliance construction, a maximum of warmth is absorbed from the air. Even at extreme temperatures below zero. No...