Catalog excerpts
HIGH-CAPACITY HEAT PUMPS in large-scale buildings, industry, power plants and process technology HEAT PUMPS
Open the catalog to page 1Economic, ecological and ethically convincing »» RESPONSIBILITY I ncreasing energy costs are presenting industry, commerce, trade and above all local authorities with huge challenges. The energy costs for space heating and air-conditioning or process heat represent by far the highest cost factor. The decision-makers are also being required to save primary energy and to reduce pollutants and CO2 emissions. Renewable energy from ambient warmth or exhaust heat utilisation will in the long run guarantee the supply of energy economically, efficiently and without risk. The new generation of heat...
Open the catalog to page 2Due to the savings in energy and operational costs achieved in comparison to conventional heating or cooling systems, the use of high-capacity heat pumps is especially economical and environmentally friendly. A further essential usage potential of heat pump technology for increasing energy efficiency lies in energy and power plant technology as well as in district heating networks. Chemical, mechanical, endogenous and exogenous processes of all kinds can be used as heat sources or heat sinks. Exhaust heat of all kinds from exhaust air, cooling water or heat from waste water can be used...
Open the catalog to page 3INNOVATIVE TECHNOLOGY Fit for future OCHSNER industrial heat pumps work efficiently and are environmentally friendly, achieving low operating costs, maximum operational safety and longevity. Components of the highest quality, decades of experience and a simple, compact design are the basis for energy efficiency, operational safety and customer satisfaction. During the past years, OCHSNER has continuously re-engineered its high-capacity heat pump series. The aim of this research and development program was especially » » » » » » » » to increase the COP values to increase the flow...
Open the catalog to page 4Regulation and control technology » he control terminal with LCD-display allows the reading of T all in- and outputs, the changes in operational temperature as well as the acoustic and optical display of all malfunction reports. » he control has been developed especially for the high-perT formance compressor with Economizer in heat pump operation, as well as for the two-stage high-temperature refrigerant circuit resp. turbocompressor. All measured values are monitored and regulated continuously and in real time. » SmartGrid compatible » Communicable control for the simple integration in the...
Open the catalog to page 5Product overview Series ISWS, IWWS With scroll compressor Compressor » Semi-hermetic compact scroll compressor » Twin-shaft rotation displacement machines with asymmetric high-performance profiles » Slide-switch control, rotation speed control (optional) » High operational safety by means of efficient force-fed lubrication » Maintenance-free operation » Mechanical soft-start using pressure compensation whenever the compressor is switched on Series IWWT, ISWT with turbocompressor Compressor » Turbocompressor, two-stage » Oil-free operation via magnet bearing » Highest possible COP in...
Open the catalog to page 6Electronic OeCC injection technology (OCHSNER electronic Cooling Cycle Controller) » Injector for evaporator and Economizer » Highest COP due to precise overheat control » Maximum evaporator utilisation due to stable overheating throughout the complete operational range » High security due to full compressor protection (no liquid slugging) OVI-Technology (OCHSNER Vapour Injection) » Super-cooling circuit with partial flow vapour injection » Increase in heating capacity by increased mass flow » Flow temperatures up to 65°C Refrigerant circuit » Tube-bundle heat exchanger as evaporator and...
Open the catalog to page 7Heating, cooling, energy recuperation in buildings, commerce, sports facilities »» LARGE VOLUME BUILDINGS Heating and air-conditioning of office buildings, residential buildings, administrative buildings, educational establishments, hospitals, supermarkets, warehouses, manufacturing facilities etc. »» CATERING INDUSTRY AND SPORTS FACILITIES Heating for accommodation areas, swimming pool heating, hot-water heating, air conditioning. Short pay-back periods due to continuous high heat loads. Heating of greenhouses or pools for fish breeding Icing prevention on roads, railroads, concrete roads,...
Open the catalog to page 8Energy recuperation from process and exhaust heat in industry, process and power station engineering »» Utilisation of low-temperature exhaust heat (up to 30°C) in order to generate room and process heat (up to 98°C) Low-temperature exhaust heat, which cannot be reutilised using conventional heat exchangers, is available in large quantities, especially as a result of mechanical processes or cooling processes in the chemical, pharmaceutical and food industries. Using heat pumps, this low-temperature exhaust heat can be efficiently brought back up to a useable temperature level. »» The heat...
Open the catalog to page 9Implemented OCHSNER-Projects »» VATTENFALL HAMBURG »» MEGABAUMAX SALZBURG »» FRONIUS WELS »» ALTES RATHAUS (OLD TOWN HALL) BONN »» Überlandwerk Krumbach Heat source EDV-Server room, Heating capacity 2x 360 kW, Cooling capacity 2x 245 kW Heat source ground probes, heating capacity 375 and 170 kW, Cooling capacity 395 and 203 kW Heat source ground water, heating capacity 142 kW, Cooling capacity 157 kW Heat source ground water, heating capacity 327 kW Heat source ground water, heating capacity 337 kW Heat source waste water sewer, heating capacity 120 kW
Open the catalog to page 10Vattenfall Hamburg Megabaumax Salzburg Citigroup Frankfurt »» STADTWERKE AMSTETTEN »» EVANGELISCHE GEMEINDE BONN »» CITYGROUP FRANKFURT »» GEMÜ EMMEN Heat source waste water sewer, heating capacity 228 kW Heat source cooling water, heating capacity 2x 175 kW Heat source ground water, heating capacity 930 kW Heat source ground water, heating capacity 2x 130 kW Heat source breeding pool, heating capacity 440 kW
Open the catalog to page 11All OCHSNER catalogs and technical brochures
-
AIR 85 C14A
2 Pages
-
TERRA 27 HPLA
2 Pages
-
AQUA 14 HSTA
2 Pages
-
EUROPA 300 L
2 Pages
Archived catalogs
-
OCHSNER hot water heat pumps
8 Pages
-
TERRA DX 5 HCUA
2 Pages
-
GMDW 13 PLUS
2 Pages
-
GMDW 8 PLUS
2 Pages
-
OCHSNER high tech heat pumps
44 Pages
-
GMSW 11 PLUS
2 Pages
-
AQUA 11 HSTA
2 Pages
-
AIR EAGLE 414 C11B T200
2 Pages
-
AIR BASIC 109 C11B G1-1
2 Pages
-
GMDW 11 PLUS
2 Pages
-
Hot Water Heat Pumps
8 Pages
-
High-Tech Heat Pumps
32 Pages
-
High tech heat pumps
32 Pages
-
ECO AIR/WATER HEAT PUMP
6 Pages