1. Catalogs
  2. OCHSNER
  3. GMSW 11 PLUS
video corpo

GMSW 11 PLUS
1 /2Pages

GMSW 11 PLUS

GMSW 11 PLUS
1 /2Pages

Catalog excerpts

GMSW 11 PLUS-1

OCHSNER HEAT PUMPS | GEOTHERMAL BRINE GMSW 11 PLUS MONOVALENT HEATING SYSTEM WITH BRINE AS HEAT SOURCE ORDER NUMBER: 264820 SERIES: GOLF MIDI PLUS TF MAX. 65 °C APPLIANCE DATA Dimensions HxWxD Hydraulic connection Casing colour Plate heat exchanger Phases/nominal voltage/frequency Application range [~]/[V]/[Hz] Output factor cos φ Fuse protection (tripping curve “C”) Heat transfer medium temperature differential Max. refrigerant operating pressure Max. heat transfer medium operating pressure Heat transfer medium Test pressure Heat transfer medium flow rate Internal pressure differential Max. starting current/max. with soft start Flow meter FM standard Circulation pump heat sink (WNA) Residual head I WNA external, incl. FM HEATING MODE PERFORMANCE FIGURES (to EN 14511) Standard point B0/W35 Heating output Total power consumption / operating current Heating output Operating point B0/W60 Heating output Total power consumption / operating current COP Refrigerant Refrigerant charge Operating point B0/W50 Total power consumption / operating current REFRIGERANT CIRCUIT Output levels Speed Voltage/frequency EVAPORATOR Type Plate heat exchanger Max. heat transfer medium operating pressure Max. refrigerant operating pressure Heat transfer medium temperature differential Application range Heat transfer medium Test pressure Heat transfer medium flow rate Internal pressure differential Flow meter (FM) standard Circulation pump heat source (WQA) Residual head I WQA external, incl. FM OCHSNER heat pumps are domestic appliances in accordance with the Machinery Directive. Sound power level/sound pressure level (at 1 m

 Open the catalog to page 1
GMSW 11 PLUS-2

PRODUCT DATA ErP: GMSW 11 PLUS A Heat source inlet C Heat pump flow D Heat pump return Energy consumption Energy consumption kvs 10, pressure loss 32 mbar Brine collector set for shallow laying Pressure loss 78 mbar incl. brine distributor Prim.: 1”/ 19 mbar Sec.: 1”/ 25 mbar MEDIUM TEMPERATURE Heat pump separating cylinders RECOMMENDED ACCESSORIES Energy consumption Draw-off profile B Heat source outlet GMSW 11 PLUS / GEOTHERMAL BRINE Tank losses Soil conditions Max. spec. extraction capacity Max. spec. extraction capacity at 1800 h/a at 2400 h/a Sound power level Controller class with room...

 Open the catalog to page 2

All OCHSNER catalogs and technical brochures

  1. AIR 85 C14A

    2  Pages

  2. TERRA 27 HPLA

    2  Pages

  3. AQUA 14 HSTA

    2  Pages

  4. EUROPA 300 L

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.