1. Catalogs
  2. OCHSNER
  3. GMDW 13 PLUS
video corpo

GMDW 13 PLUS
1 /2Pages

GMDW 13 PLUS

GMDW 13 PLUS
1 /2Pages

Catalog excerpts

GMDW 13 PLUS-1

OCHSNER HEAT PUMPS | DIRECT GEOTHERMAL EXTRACTION GMDW 13 PLUS MONOVALENT HEATING SYSTEM WITH GROUND AS HEAT SOURCE ORDER NUMBER: 274650 SERIES: GOLF MAXI PLUS TF MAX. 65 °C APPLIANCE DATA Dimensions HxWxD Hydraulic connection Casing colour Plate heat exchanger Phases/nominal voltage/frequency Application range [~]/[V]/[Hz] Output factor cos φ Fuse protection (tripping curve “C”) Heat transfer medium temperature differential Max. refrigerant operating pressure Max. heat transfer medium operating pressure Max. starting current/max. with soft start Test pressure Heat transfer medium flow rate Internal pressure differential Total power consumption / operating current Heating output REFRIGERANT CIRCUIT Refrigerant COMPRESSOR Type Output levels Voltage/frequency EVAPORATOR Type Tube evaporator Length per circuit Material Max. refrigerant operating pressure * umber of circuits possible for optimum soil conditions: N cohesive soil/moist or better at max. 1800 h/a Operating point E0/W60 Total power consumption / operating current Operating point E0/W50 Total power consumption / operating current Refrigerant charge (from-to) Heating output Operating point E-1/W35 Total power consumption / operating current Flow meter FM standard Residual head I WNA external, incl. FM Circulation pump heat sink WNA HEATING MODE PERFORMANCE FIGURES (to EN 14511) Heating output Sound power level/sound pressure level (at 1 m distance) Heat transfer medium Copper / seamless PVC outer casing [bar] OCHSNER heat pumps are domestic appliances in accordance with the Machinery Directive.

 Open the catalog to page 1
GMDW 13 PLUS-2

PRODUCT DATA ErP: GMDW 13 PLUS COLDER Energy consumption MEDIUM TEMPERATURE kvs 16, pressure loss 24 mbar Heat pump separating cylinders Energy consumption RECOMMENDED ACCESSORIES Energy consumption Draw-off profile Tank losses Sound power level Controller class with room remote control EXTRACTION SURFACE Basic cooling capacity (at E4/W35) Controller class without room remote control Controller contribution [%] Max. connection length to collection shaft Controller contribution [%] GMDW 13 PLUS / DIRECT GEOTHERMAL EXTRACTION Geothermal collector: The geothermal collectors O-Tube Pro are filled...

 Open the catalog to page 2

All OCHSNER catalogs and technical brochures

  1. AIR 85 C14A

    2  Pages

  2. TERRA 27 HPLA

    2  Pages

  3. AQUA 14 HSTA

    2  Pages

  4. EUROPA 300 L

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.