Specifications:
  • Dimensions: 1150x400x650 mm
  • Hydraulic connection: 1 1/4 inch
  • Weight: 120 kg
  • Casing color: Tiger white / grey RAL 7016
  • Phases/nominal voltage/frequency: 3/400/50
  • Sound power level: 50.10 dBA
Performance Figures:
  • Standard point E4/W35: Heating output 12.10 kW, COP 5.10
  • Operating point E-1/W35: Heating output 10.10 kW, COP 4.60
  • Operating point E0/W50: Heating output 9.00 kW, COP 3.00
  • Operating point E0/W60: Heating output 8.90 kW, COP 2.30
Condenser:
  • Type: Plate heat exchanger
  • Material: Stainless steel 1.4301
  • Max. refrigerant operating pressure: 30 bar
Refrigerant Circuit:
  • Refrigerant: R407C
  • Refrigerant charge: 4.8-8.0 kg
Compressor:
  • Type: Scroll
  • Speed: 2900 rpm
Evaporator:
  • Type: Tube evaporator
  • Material: Copper with seamless PVC outer casing
Geothermal Collector:
  • O-Tube Pro collectors filled with nitrogen for leakage monitoring
  • Minimum clearance of 1.5 m to building components
  • Minimum spacing for collector pipes: 0.5 m
Recommended Accessories:
  • Heat pump separating cylinders
  • DHW tank
  • 3-way switching module
Extraction Surface Requirements:
  • Basic cooling capacity: 9.8 kW
  • Extraction surface at 1800 h/a: 392 m²
  • Extraction surface at 2400 h/a: 490 m²
Conditions: Soil conditions and extraction capacities are specified according to VDI 4640 or ÖWAV 207 standards.
See more

Catalog excerpts

GMDW 11 PLUS-1

OCHSNER HEAT PUMPS | DIRECT GEOTHERMAL EXTRACTION GMDW 11 PLUS MONOVALENT HEATING SYSTEM WITH GROUND AS HEAT SOURCE ORDER NUMBER: 274600 SERIES: GOLF MIDI PLUS TF MAX. 65 °C APPLIANCE DATA Dimensions HxWxD Hydraulic connection Casing colour Plate heat exchanger Phases/nominal voltage/frequency Application range [~]/[V]/[Hz] Output factor cos φ Fuse protection (tripping curve “C”) Heat transfer medium temperature differential Max. refrigerant operating pressure Max. heat transfer medium operating pressure Max. starting current/max. with soft start Test pressure Heat transfer medium flow rate Internal pressure differential Total power consumption / operating current Heating output REFRIGERANT CIRCUIT Refrigerant COMPRESSOR Type Output levels Voltage/frequency EVAPORATOR Type Tube evaporator Length per circuit Material Max. refrigerant operating pressure * umber of circuits possible for optimum soil conditions: N cohesive soil/moist or better at max. 1800 h/a Operating point E0/W60 Total power consumption / operating current Operating point E0/W50 Total power consumption / operating current Refrigerant charge (from-to) Heating output Operating point E-1/W35 Total power consumption / operating current Flow meter FM standard Residual head I WNA external, incl. FM Circulation pump heat sink WNA HEATING MODE PERFORMANCE FIGURES (to EN 14511) Heating output Sound power level/sound pressure level (at 1 m distance) Heat transfer medium Copper / seamless PVC outer casing [bar] OCHSNER heat pumps are domestic appliances in accordance with the Machinery Directive.

 Open the catalog to page 1
GMDW 11 PLUS-2

PRODUCT DATA ErP: GMDW 11 PLUS COLDER Energy consumption 3-way switching module External PHE for DHW heating Prim.: 1”/ 63 mbar Sec.: 1”/ 82 mbar kvs 10, pressure loss 44 mbar Heat pump separating cylinders Energy consumption RECOMMENDED ACCESSORIES Draw-off profile Energy consumption Tank losses Sound power level Controller class with room remote control EXTRACTION SURFACE Basic cooling capacity (at E4/W35) Controller class without room remote control Controller contribution [%] Max. connection length to collection shaft Controller contribution [%] GMDW 11 PLUS / DIRECT GEOTHERMAL EXTRACTION...