1. Catalogs
  2. OCHSNER
  3. AIR EAGLE 414 C11B T200
video corpo

AIR EAGLE 414 C11B T200

AIR EAGLE 414 C11B T200

AIR EAGLE 414 C11B T200

Product catalog summary
Overview: The Ochsner Air Eagle 414 C11B T200 is an air/water heat pump designed for domestic use, compliant with the Machinery Directive. It features a horizontal split evaporator and is suitable for both heating and cooling applications.
Specifications:
  • Outdoor Unit Dimensions: 1260x1480x965 mm, Weight: 200 kg
  • Indoor Unit Dimensions: 1908x680x871 mm, Weight: 203/471 kg
  • Hydraulic Connection: 1” union nut
  • Phases/Voltage/Frequency: 1/230/50 for outdoor unit, 3/400/50 or 1/230/50 for electric immersion heater
  • Electric Immersion Heater: 8.8 kW
  • Sound Levels: Indoor unit < 50 dBA, Outdoor unit 57 dBA
Performance:
  • Heating Mode (EN 14511):
    • Standard Point A7/W35: Heating Output 3.50 - 10.60 kW, COP 4.50
    • Operating Point A2/W35: Heating Output 3.10 - 10.20 kW, COP 3.10
    • Standard Point A7/W55: Heating Output 3.90 - 11.00 kW, COP 3.10
    • Standard Point A-7/W34: Heating Output 2.60 - 8.60 kW, COP 2.90
  • Cooling Mode:
    • Operating Point A35/W18: Cooling Capacity 2.60 - 6.60 kW, EER 3.30
Components:
  • Condenser: Plate heat exchanger, Stainless steel
  • Refrigerant: R410A, Hot gas defrost technology
  • Compressor: Scroll, Infinitely variable output
  • Fan: Axial, Power consumption 230 W
  • Evaporator: Finned tube, Copper/aluminium
Additional Features:
  • Multi Tower All-in-One: Includes DHW tank, buffer tank, 3-way switching valve, safety valve, electric auxiliary heater, flow meter, air vent valve, high-efficiency circulation pump, plate heat exchanger, and more.
Energy Efficiency:
  • Low Temperature (35°C): SCOP 4.85
  • Medium Temperature (55°C): SCOP 3.87
Usage Limits:
  • Outdoor Temperature/Max. Heat Pump Flow Temperature: A-10/W60°C, A-15/W58°C, A-20/W55°C
  • Suitable for underfloor heating and radiators at specified temperatures
See more

Catalog excerpts

AIR EAGLE 414 C11B T200-1

OCHSNER HEAT PUMPS | AIR AIR EAGLE 414 C11B T200 AIR/WATER HEAT PUMP INCL. HORIZONTAL SPLIT EVAPORATOR ORDER NUMBER: 285900 SERIES: T200 TF MAX. 65 °C Indoor unit A Refrigerant line LL (liquid line) E DHW circulation 1/2” SPLIT APPLIANCE DATA B Refrigerant line HG (hot gas line) F DHW 1” C FL heating/cooling 1” G Cold water 1” Dimensions of outdoor unit HxWxD Dimensions of indoor unit HxWxD Hydraulic connection Weight of outdoor unit Weight of indoor unit Casing colour Plate heat exchanger Max. refrigerant operating pressure Max. heat transfer medium operating pressure Heat transfer medium temperature differential Application range Heat transfer medium Test pressure Phases/nominal voltage/frequency Outdoor unit, controller Phases/nominal voltage/frequency Electric immersion heater Electric immersion heater internal Fuse protection (tripping curve “C”) Max. starting current, compressor Sound power level (A7/W35)/sound pressure level (at 10 m distance), outdoor unit Internal pressure differential Flow meter FM standard Circulation pump heat sink WNA Residual head I WNA external, incl. FM REFRIGERANT CIRCUIT Refrigerant Defrost technology Refrigerant charge (from-to) HEATING MODE PERFORMANCE FIGURES (to EN 14511) Output levels Standard point A7/W35 Heating output range Heating output/power consumption Speed Voltage/frequency Operating point A2/W35 Heating output range Heating output/power consumption Standard point A7/W55 Heating output range Heating output/power consumption Type Number Voltage/frequency Power consumption Heating output range Heating output/power consumption EVAPORATOR Unit type Type Number Casing material Stainless steel / powder coated, grey RAL 7016 2.90 Max. refrigerant operating pressure COOLING MODE PERFORMANCE FIGURES Relative humidity Heat transfer medium temperature differential Cooling capacity range Nominal cooling capacity Total nominal power consumption Energy efficiency ratio EER at nominal output Air flow rate Application range min./max *Starting current, compressor with locked rotor **Sound pressure level measured in a free field; sound power levels measured at max. nominal speed OCHSNER heat pumps are domestic appliances in accordance with the Machinery Directive. Sound power/sound pressure level (at 3 m distance), indoor unit Heat transfer medium flo

 Open the catalog to page 1
AIR EAGLE 414 C11B T200-2

Energy consumption MEDIUM TEMPERATURE • Pressure maintaining device (DEV), on site Max. connection length AIR EAGLE 414 C11B T200 • DHW tank, 168 l • Buffer tank 100 l, heating / cooling • -way switching valve for DHW heating and/or 3 defrosting • Safety valve • Electric auxiliary heater 8.8 kW • low meter for safety monitoring and heat quantity F measurement for heating / cooling / DHW heating • Air vent valve • High efficiency energy saving circulation pump • Plate heat exchanger / condenser • Drain and fill valve Energy consumption Fully equipped MULTI TOWER Outdoor unit PRODUCT DATA ErP:...

 Open the catalog to page 2

All OCHSNER catalogs and technical brochures

  1. AIR 85 C14A

    2  Pages

  2. TERRA 27 HPLA

    2  Pages

  3. AQUA 14 HSTA

    2  Pages

  4. EUROPA 300 L

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.