Catalog excerpts
OCHSNER HEAT PUMPS | AIR AIR BASIC 109 C11B G1-1 (ELW 4) AIR/WATER HEAT PUMP INCL. VERTICAL SPLIT EVAPORATOR ORDER NUMBER: 285600 SERIES: G1-1 Indoor unit A FL heating/cooling B RTN heating/ cooling F Refrigerant line G Controller 230 V HG (hot gas line) SPLIT APPLIANCE DATA C FL DHW charging D RTN DHW charging H booster heater I Sensor < 12 V 400 V/230 V E Refrigerant line LL (liquid line) Dimensions of outdoor unit HxWxD Dimensions of indoor unit HxWxD Hydraulic connection Weight of outdoor unit Weight of indoor unit Casing colour Phases/nominal voltage/frequency Outdoor unit, controller Phases/nominal voltage/frequency Electric immersion heater Electric immersion heater internal Sound power/sound pressure level (at 1 m distance), indoor unit Standard point A10/W35 Heating output range Total heating output/power consumption Fuse protection (tripping curve “C”) Max. starting current, compressor HEATING MODE PERFORMANCE FIGURES (to EN 14511) Sound power/sound pressure level (at 10 m distance), outdoor unit CONDENSER Type Operating point A7/W35 Heating output range Total heating output/power consumption Plate heat exchanger Heat transfer medium temperature differential Max. refrigerant operating pressure Max. heat transfer medium operating pressure Heating output range Application range Total heating output/power consumption Heat transfer medium Test pressure Heat transfer medium flow rate Internal pressure differential Heating output range Flow meter FM standard Total heating output/power consumption Circulation pump heat sink WNA Residual head I WNA external, incl. FM Heating output range REFRIGERANT CIRCUIT Total heating output/power consumption Defrost technology Refrigerant charge Total heating output/power consumption COOLING MODE PERFORMANCE FIGURES Cooling capacity range Nominal cooling capacity Total nominal power consumption Energy efficiency ratio EER at nominal output Voltage/frequency Operating point A35/W12 Power consumption Cooling capacity range Unit type Total nominal power consumption Nominal cooling capacity Energy efficiency ratio EER at nominal output Operating point A35/W7(1) Cooling capacity range Nominal cooling capacity Total nominal power consumption built-in Finned tube [pce] Energy efficiency ratio EER at nominal output Status: 2019-05-21 Rotary piston Output levels Application range min./max only possible with buffer tank *Starting current, compressor with locked rotor **Sound pressure level measured in a free field; sound power levels measured at max. nominal speed [1] OCHSNER heat pumps are domestic appliances in accordance with the Machinery Directive.
Open the catalog to page 1Energy consumption MEDIUM TEMPERATURE Energy consumption RECOMMENDED ACCESSORIES Heat pump buffer tank Booster heater output Bivalent parallel Sizing according to calculated value (offer program), but with minimum 50% of building heat load Draw-off profile Tank losses Bivalent partial parallel Bivalent alternative Sound power level Sizing to 100% of building heat load Max. connection length Controller contribution [%] Controller contribution [%] Controller class with room remote control Controller class without room remote control Sizing to 100% of building heat load Primary 1” / 35 mbar...
Open the catalog to page 2All OCHSNER catalogs and technical brochures
-
AIR 85 C14A
2 Pages
-
TERRA 27 HPLA
2 Pages
-
AQUA 14 HSTA
2 Pages
-
EUROPA 300 L
2 Pages
Archived catalogs
-
OCHSNER hot water heat pumps
8 Pages
-
TERRA DX 5 HCUA
2 Pages
-
GMDW 13 PLUS
2 Pages
-
GMDW 8 PLUS
2 Pages
-
OCHSNER high tech heat pumps
44 Pages
-
GMSW 11 PLUS
2 Pages
-
AQUA 11 HSTA
2 Pages
-
AIR EAGLE 414 C11B T200
2 Pages
-
GMDW 11 PLUS
2 Pages
-
Hot Water Heat Pumps
8 Pages
-
High-Tech Heat Pumps
32 Pages
-
High tech heat pumps
32 Pages
-
ECO AIR/WATER HEAT PUMP
6 Pages