AIR BASIC 109 C11B G1-1
2Pages

{{requestButtons}}

Catalog excerpts

AIR BASIC 109 C11B G1-1 - 1

OCHSNER HEAT PUMPS | AIR AIR BASIC 109 C11B G1-1 (ELW 4) AIR/WATER HEAT PUMP INCL. VERTICAL SPLIT EVAPORATOR ORDER NUMBER: 285600 SERIES: G1-1 Indoor unit A FL heating/cooling B RTN heating/ cooling F Refrigerant line G Controller 230 V HG (hot gas line) SPLIT APPLIANCE DATA C FL DHW charging D RTN DHW charging H booster heater I Sensor < 12 V 400 V/230 V E Refrigerant line LL (liquid line) Dimensions of outdoor unit HxWxD Dimensions of indoor unit HxWxD Hydraulic connection Weight of outdoor unit Weight of indoor unit Casing colour Phases/nominal voltage/frequency Outdoor unit, controller Phases/nominal voltage/frequency Electric immersion heater Electric immersion heater internal Sound power/sound pressure level (at 1 m distance), indoor unit Standard point A10/W35 Heating output range Total heating output/power consumption Fuse protection (tripping curve “C”) Max. starting current, compressor HEATING MODE PERFORMANCE FIGURES (to EN 14511) Sound power/sound pressure level (at 10 m distance), outdoor unit CONDENSER Type Operating point A7/W35 Heating output range Total heating output/power consumption Plate heat exchanger Heat transfer medium temperature differential Max. refrigerant operating pressure Max. heat transfer medium operating pressure Heating output range Application range Total heating output/power consumption Heat transfer medium Test pressure Heat transfer medium flow rate Internal pressure differential Heating output range Flow meter FM standard Total heating output/power consumption Circulation pump heat sink WNA Residual head I WNA external, incl. FM Heating output range REFRIGERANT CIRCUIT Total heating output/power consumption Defrost technology Refrigerant charge Total heating output/power consumption COOLING MODE PERFORMANCE FIGURES Cooling capacity range Nominal cooling capacity Total nominal power consumption Energy efficiency ratio EER at nominal output Voltage/frequency Operating point A35/W12 Power consumption Cooling capacity range Unit type Total nominal power consumption Nominal cooling capacity Energy efficiency ratio EER at nominal output Operating point A35/W7(1) Cooling capacity range Nominal cooling capacity Total nominal power consumption built-in Finned tube [pce] Energy efficiency ratio EER at nominal output Status: 2019-05-21 Rotary piston Output levels Application range min./max only possible with buffer tank *Starting current, compressor with locked rotor **Sound pressure level measured in a free field; sound power levels measured at max. nominal speed [1] OCHSNER heat pumps are domestic appliances in accordance with the Machinery Directive.

Open the catalog to page 1
AIR BASIC 109 C11B G1-1 - 2

Energy consumption MEDIUM TEMPERATURE Energy consumption RECOMMENDED ACCESSORIES Heat pump buffer tank Booster heater output Bivalent parallel Sizing according to calculated value (offer program), but with minimum 50% of building heat load Draw-off profile Tank losses Bivalent partial parallel Bivalent alternative Sound power level Sizing to 100% of building heat load Max. connection length Controller contribution [%] Controller contribution [%] Controller class with room remote control Controller class without room remote control Sizing to 100% of building heat load Primary 1” / 35 mbar...

Open the catalog to page 2

All OCHSNER catalogs and technical brochures

  1. AIR 85 C14A

    2 Pages

  2. AQUA 14 HSTA

    2 Pages

  3. EUROPA 300 L

    2 Pages

Archived catalogs

  1. GMDW 13 PLUS

    2 Pages

  2. GMDW 8 PLUS

    2 Pages

  3. GMSW 11 PLUS

    2 Pages

  4. AQUA 11 HSTA

    2 Pages

  5. GMDW 11 PLUS

    2 Pages