Overview: The document details SL skirting trunking and RAUDUO electrical/heating trunking systems, designed for efficient electrical installations in living spaces. These systems feature modular designs for simplified installation and cable management, ensuring a neat setup.
SL Skirting Trunking:
  • Available in dimensions of 20x50 mm, 20x70 mm, and 20x110 mm.
  • Variants include SL, SL-L (with sealing lip), and SL-T (for carpeted floors).
  • Features easy installation, flexible device placement, and compatibility with standard devices.
  • Made from self-extinguishing PVC, with a fire resistance classification of UL94: V-0.
  • Complies with VDE DIN EN 50085-1 and 50085-2-1 standards.
RAUDUO Electrical/Heating Trunking:
  • Combines electrical and heating cable management.
  • Maintains cable temperatures below 30°C.
  • Suitable for standard NYM cables.
  • Optional sealing lips for precise connections.
  • Dimensions: 40 mm height and 105 mm width.
Installation and Components:
  • Device tanks allow customizable setups.
  • Includes corners, cover couplings, and device supports.
  • Installation requires adherence to safety and compliance standards.
Technical Specifications:
  • Cable capacity varies by trunking size.
  • Fire and mechanical resistance specified, with IP40 protection level.
  • Temperature ranges for transport, storage, and use provided.
Conclusion: SL and RAUDUO trunking systems offer versatile solutions for electrical and heating installations, focusing on safety, flexibility, and ease of installation, suitable for new constructions and renovations.
Product Overview: The document also covers various trunking systems and accessories for indoor cable routing, including corner and skirting trunking solutions.
Corner Trunking:
  • ECK Corner Trunking: Available in 35mm and 50mm widths for vertical/horizontal routing.
  • Transition Pieces: For transitioning between trunking systems.
  • End Pieces: Provide a clean finish.
Skirting Trunking:
  • RAUDUO Skirting Trunking: Features thermally separated chambers for cables and pipes.
  • Trunking Covers: Snap onto the base, available in various sizes and colors.
  • External and Internal Corners: For changing trunking direction.
  • End Pieces: For a clean finish.
Accessories:
  • Heating Pipe Support: Guides pipes within the RAUDUO system.
  • Device Tanks: For installing devices with support clamps.
  • Insulating Foam: For use with the RAUDUO system.
  • Trunking Coupling: Connects skirting trunking sections.
Contact Information: OBO Bettermann Vertrieb Deutschland GmbH Co. KG provides customer service contact details for further inquiries.
See more

Catalog excerpts

Skirting Trunking SL and RAUDUO-1

SL skirting trunking and RAUDUO electrical/heating trunking The optimum solution for electrical installations in living spaces

 Open the catalog to page 1
Skirting Trunking SL and RAUDUO-2

SL/SL-L/SL-T skirting trunking For flexible electrical installations Trunking for living spaces with added value The practical modular design ensures huge time savings during mounting, ensuring uncomplicated cable routing. The matched system components provide a flexible and individual electrical supply. The device tanks are installed at any point in the trunking, in the style of a construction kit – this means that the trunking system brings to an end the problem of "cable spaghetti", because sockets and connections for telephones, audio and PCs can be located exactly where they are required....

 Open the catalog to page 2
Skirting Trunking SL and RAUDUO-3

06 LFS Broschüre Sockelleistenkanal SL und Elektro-/Heizungskanal RAUDUO / en / 2021/04/14 11:13:17 11:13:17 (LLExport_02886) / With the SL-L, the sealing lip is suitable for existing buildings for close-fitting wall and floor connections Flattened bracket Perfect adaptation Tapered lip end Soft material Flawless sealing 6 mm lip width Depth compensation up to 5 mm No ingress of dirt Practical supply using vertical triangular trunking Delivery form Cover and base in the box Base with base perforation Fittings and device tanks in the box Stock length Delivery colours RAL 9001 cream white RAL 9010...

 Open the catalog to page 3
Skirting Trunking SL and RAUDUO-4

System overview For all applications in single or multiple-occupier dwellings, whether a new building or renovation: • The product range comprises the dimensions 20 x 50 mm, 20 x 70 mm and 20 x 110 mm • Connection solutions for all standard devices in support ring and support clamp design • Length of the standard profiles 2 m • Versions available in RAL 9010 (trunking width: 50, 70 and 110 mm) • Matching accessories to maintain the protection cla

 Open the catalog to page 4
Skirting Trunking SL and RAUDUO-5

Trunking Internal corner External corner Cover coupling Device support with integrated double socket Device support, empty, for standard devices of support ring design 06 LFS Broschüre Sockelleistenkanal SL und Elektro-/Heizungskanal RAUDUO / en / 2021/04/14 11:13:17 11:13:17 (LLExport_02886) / Device support, including panel, for the installation of central plate devices according to DIN 49075, with support clamp

 Open the catalog to page 5
Skirting Trunking SL and RAUDUO-6

Classification according to DIN EN 50085-2-1 The systems possess integrated partitions, thus allowing the installation of cables of different voltage levels. With trunking widths of 50, 70 and 110 mm and a height of 20 mm, the system is hardly distinguishable visually from a normal skirting board. Connection solution for the installation of standard devices Structure of a device support: • Device support for screwing to a wall • Front plate to be clipped on • Side adapter plate at the height of the skirting board; cover (only for DIN connections)

 Open the catalog to page 6
Skirting Trunking SL and RAUDUO-7

06 LFS Broschüre Sockelleistenkanal SL und Elektro-/Heizungskanal RAUDUO / en / 2021/04/14 11:13:17 11:13:17 (LLExport_02886) / Apply the device support to the top of the base and screw to the wall. Select the adapter plate according to the height of the skirting board. No adapter plate is available for SL 20 x 110. Connect and screw on the holder. Clip the front plate onto the cover. Mount the connection cover.

 Open the catalog to page 7
Skirting Trunking SL and RAUDUO-8

Mounting of SL device tank with double socket With the 50 mm trunking height, apply the device support to the mounted skirting board base in such a way that the two bars serve as spacers. Then, drill the hole and screw to the wall (image without mounted socket base). Connect the device support. When using the 70 mm-high SL trunking, break out the two bars (spacer). Place the device support directly on the base. When using the 50 mm-high SL trunking, the supplied adapter plate must be engaged on both sides before mounting the device tank.

 Open the catalog to page 8
Skirting Trunking SL and RAUDUO-9

06 LFS Broschüre Sockelleistenkanal SL und Elektro-/Heizungskanal RAUDUO / en / 2021/04/14 11:13:17 11:13:17 (LLExport_02886) / Hang the device tank in the SL base. Place the device panel, including the screw, in the opening of the device tank and screw it tight. After mounting, an electrical test must be performed by an authorised electrical specialist. When mounted at the end of a skirting board, the side opening of the device tank is closed off with the side closure – part to be ordered separately.

 Open the catalog to page 9
Skirting Trunking SL and RAUDUO-10

Installation options Individual devices, empty (SL/SL-T/SL-L) This device tank is suitable for the installation of support ring devices with a 60 mm fastening spacing from all manufacturers. * When using the 50 mm-high skirting trunking, the supplied closing piece must be engaged on both sides before mounting the device tank. ** When mounting at the end of a piece of skirting board, the opening of the device tank is closed off with the side closure (separate part). Side closure** Device tank, empty, incl. panel (DIN 49075) Concealed range (SIGNO Standard)

 Open the catalog to page 10
Skirting Trunking SL and RAUDUO-11

Installation options Device tank, empty (SL/SL-T/SL-L) This device tank is suitable for the installation of support clamp devices with 60 mm fastening spacing from all manufacturers. 06 LFS Broschüre Sockelleistenkanal SL und Elektro-/Heizungskanal RAUDUO / en / 2021/04/14 11:13:17 11:13:17 (LLExport_02886) / * When using the 50 mm-high skirting trunking, the supplied closing piece must be engaged on both sides before mounting the device tank. ** When mounting at the end of a piece of skirting board, the opening of the device tank is closed off with the side closure (separate part). Device tank,...

 Open the catalog to page 11
Skirting Trunking SL and RAUDUO-12

Technical data SL, SL-T, SL-L Cable capacity Maximum cable diameter in mm Classification according to DIN EN 50085-2-1 Resistant to knocks during installation and use Minimum temperature for transport and storage Minimum temperature for installation and use Fire resistance Current passage Without current passage Electrically insulating Protection level of the housing With tool On the wall Fastening on the wall and support on the floor Fastening on the wall and support on a horizontal surface Available functions Nominal voltage Mechanical resistance

 Open the catalog to page 12
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.