QUASAR P8EBQY Contactless + Manual, Refrigerated QUASAR PEBQY Contactless + Manual, Non-Refrigerated This surface mount hydration station combo has two activation methods. The bottle filler includes an electronic sensor for a contactless (touch free) activation and a 30 second shut off timer. The drinking fountain is activated via one of four push-pads. The Bottle Counter conveniently displays the number of times the unit has been used, encouraging the refill of sports bottles. Quasar bottle fillers shall have UVC-LED treatment at the point of dispense, which disinfects the water while it is being dispensed; Killing 99.99% of bacteria. UVC-LED also cycles on periodically to keep the dispense-point sanitized between dispenses. Quasar bottle fillers shall have UVC-LED treatment at the point of dispense, which disinfects the water while it is being dispensed; Killing 99.99% of bacteria. UVC-LED also cycles on periodically to keep the dispense-point sanitized between dispenses. Key Quasar bottle filler moulded components shall contain Freshield, which utilises a silver-based antimicrobial compound that reduces the growth of micro-organisms and mildew to protect the surfaces from discolouration, odours and degradation. Suitable for public building, gymnasiums, sports complexes, hospitals, schools, and offices. SENSOR COVERAGE FILTRATION DISINFECTION AUTO-OFF WATER FLOW DRAINAGE TYPE EXTERIOR CHASSIS DIMENSIONS ALCOVE HEIGHT NET WEIGHT POWER SUPPLY COOLING PERFORMANCE FULL LOAD AMPS RATED WATTS ENERGY SYSTEM COUNTRY OF ORIGIN Bottle Filler: Contactless (Infrared sensor) Drinking Fountain: Manual (Four push-pads) Green Filter (optional), Built-in 100 micron strainer Quasar UVC-LED Bottle Filler: Yes ; Drinking Fountain: No Built in drain, Removable drip tray Antimicrobial ABS Plastic, Brushed Stainless Steel Heavy Duty Galvanised Steel 960(H) x 413(W)x 473(D) 60 LPH Rated Capacity & Base Rate (10°C in 21 °C amb. temp.) Refrigeration is on only when in use or if water temp increases during long period of standby. ANSI/NSF 61, CABO/ANSI A117.1, ADA, CE (LVD, EMC, RoHS), WRAS
Open the catalog to page 11. TRAP, STOP VALVE AND ELECTRICAL OUTLET NOT FURNISHED. 2. ALLOW 4 INCHES [102 MM] MIN. PER SIDE FOR VENTILATION. *3. RECOMMENDED ADULT BARRIER FREE HEIGHT INSTALLATION SHOWN. REDUCE HEIGHT BY 3 INCHES FOR INSTALLATIONS USED PRIMARILY BY CHILDREN AGES 12 AND YOUNGER. UNIT SHALL ALSO HAVE A MINIMUM CLEAR FLOOR SPACE 30[760] BY 48[1220]. ADJUST VERTICAL DIMENSIONS AS REQ’D TO COMPLY WITH FEDERAL, STATE, AND LOCAL CODES. 4. 1 15v GROUNDED NORTH AMERICAN DUPLEX RECEPTACLE REQUIRED. THIS DRINKING WATER COOLER IS INTENDED TO BE CONNECTED TO A 20A MINIMUM GROUND FAULT CIRCUIT INTERRUPTING fGFCD DEVICE...
Open the catalog to page 24 Pages
4 Pages
4 Pages
4 Pages
1 Page
4 Pages
4 Pages
4 Pages
2 Pages
1 Page
2 Pages
3 Pages
40 Pages
12 Pages
2 Pages
2 Pages
29 Pages
31 Pages
36 Pages
27 Pages