Owner's Manual Overview: This manual provides detailed instructions for setting up, adjusting, and maintaining the Portal Light massage chair by Oakworks®. It includes guidelines for client positioning, chair adjustments, and cleaning procedures.
Setting Up the Massage Chair:
  • Begin by moving the horizontal bar down and inserting it into the locking arm, securing it with Velcro®.
  • Loosen face rest knobs and insert the face rest platform arms into the tubes on the back of the chest pad plate.
Helping Clients onto the Chair:
  • Clients should stand beside the chair, straddle the seat, and place their knees on the knee pads before sitting down.
  • Adjust face and arm rests for optimal comfort and positioning.
Face Rest Adjustments:
  • Oakworks QuickLock™ face rest offers unlimited positioning options. Adjust vertically by loosening knobs and angle by unlocking CamLocks.
  • Face rest can be reversed to the other side of the chair if needed.
Arm Rest Adjustments:
  • Adjust the arm rest so the client's forearms rest comfortably, ensuring shoulders are relaxed.
  • Do not allow clients to use the arm rest to lift themselves out of the chair.
Folding the Massage Chair:
  • Unlock Velcro® and remove the bar from the locking arm.
  • Raise the pivot section, push up on the arm rest, and fold the face rest over the chest pad.
Seat Height Adjustment:
  • Adjust seat height by moving the angled adjustment block under the seat support.
  • Reattach the block to Velcro® after adjustment.
Carrying the Chair:
  • Fold the chair and attach the carry strap to the D-Rings on the frame.
  • Lift the chair by the main frame tubes and place the strap on your shoulder.
Cleaning & Maintenance:
  • Clean upholstery with a mild non-alcohol cleaner and disinfect with approved solutions.
  • Avoid using strong cleaners or exposing fabric to extreme temperatures and sunlight.
  • Failure to follow cleaning recommendations will void the fabric warranty.
Maximum Working Load Rating: 300 lbs (136 kg).
See more

Catalog excerpts

Portal Light Owner-1

PORTAL LIGHT by OAKWORKS ® OWNER’S MANUAL ASSEMBLED BY HAND IN THE Phone: 717.235.6807 www.oakworks.com USA R

 Open the catalog to page 1
Portal Light Owner-2

PORTAL LIGHT by OAKWORKS Face rest CamLocks Face rest knobs Arm rest OWNER’S MANUAL Chest Pad SETTING UP YOUR MASSAGE CHAIR Seat 1. Holding folded chair as shown, move the horizontal bar down & insert the bar into locking arm. (photo 1 & 2) Arm rest buckle & strap Personal item storage shelf ® 2. Wrap Velcro® around inserted bar to insure locking. (photo 3) Knee Pads 3. Loosen face rest knobs and insert face rest platform arms into the tubes on the back of the chest pad plate. (see photos 4 & 5) Horizontal bar & locking arm HELPING YOUR CLIENT ONTO THE CHAIR 1. Have your client stand on the side...

 Open the catalog to page 2
Portal Light Owner-3

ARM REST ADJUSTMENTS • Note: The arm rest is designed to support the weight of your client’s forearms. Do not allow your clients to push against the arm rest to lift themselves out of the chair. The arm rest will not support your client’s full weight. 8) Lengthen Strap 9) Tighten Strap 1. You will need to lift or lower the arm rest until your client’s forearms rest comfortably on the pad and his/her shoulders are relaxed. 2. To lower the arm rest, lift the buckle and extend the strap. (photo 8) 3. To raise the arm rest, pull on the strap. (photo 9) SEAT HEIGHT ADJUSTMENT 11) To lower the seat...

 Open the catalog to page 3
Portal Light Owner-4

PORTAL LIGHT by OAKWORKS ® Oakworks® Inc. 923 East Wellspring Road New Freedom, PA 17349 Phone: 717-235-6807 FAX: 717-235-6798 www.oakworks.com CLEANING & MAINTENANCE CLEAN your upholstered items when needed using a mild solution of 4:1 diluted non-alcohol cleaner such as Formula 409®, Fantastik®, or Green Windex® DISINFECT your fabric with Protex, MadaCide, MadaWipe, Accell TB, Virox® (Canada), or a diluted 1/10 bleach solution. Dry immediately after cleaning to remove excess cleaning solution. CAUTION MAXIMUM WORKING LOAD RATING 300 LBS. (136 KG) DO NOT use citrus based cleaners or other strong...

 Open the catalog to page 4

All Oakworks catalogs and technical brochures

  1. Antigua

    28  Pages

  2. OAKWORKS

    32  Pages

  3. PORTAL LIGHT

    4  Pages

  4. libra

    2  Pages

  5. Masters

    15  Pages

  6. Spa Catalog

    44  Pages

  7. AURORA™

    32  Pages

  8. PROLUXE™

    32  Pages

  9. Symphony

    1  Page

  10. EQUINOX

    1  Page

  11. Trolley

    8  Pages

  12. Exam Tables

    20  Pages

  13. Powerline

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.