1. Catalogs
  2. Oakworks
  3. PG Series & Ultrasound Series
video corpo

PG Series & Ultrasound Series

PG Series & Ultrasound Series
1 / 40 PagesView full catalog

PG Series & Ultrasound Series

Product catalog summary
Product Use Description
The PG and Ultrasound Tables are designed for medical examinations and procedures, intended for use by healthcare professionals. No special training is required, but reviewing safety instructions is crucial for operator and patient safety.
Important Safety Instructions
- The Fowler and Leg Rest sections cannot support a patient's full weight.
- The table is not for use as a gurney or for patient transport.
- Ensure footboards are up to prevent ground contact in low height and high tilt conditions.
- Special EMC precautions are required for Medical Electrical Equipment.
- Do not use the table adjacent to or stacked with other equipment unless verified.
- Weight limit: 550 lbs./250 kg.
- Avoid use in the presence of flammable anesthetic mixtures.
- Maximum capacity for the cardio panel is 150 lbs./68 kg.
- Ensure nothing obstructs table motion when lowering or using Trendelenburg functions.
- Motor actuators have a duty cycle of 10% (2 minutes of operation per 20 minutes).
Product Description
PG350
- Features electric lift towers, electric backrest, locking casters, and a manual 4-position leg rest.
- Powered motions include height adjustment (22”-38”), Trendelenburg/Reverse Trendelenburg, and Fowler adjustment.
- Table capacity is 550 lbs. (250 kg.).
- Options include a central base locking system, side rails, retractable foot rests, and a patient lift compatible base.
PG300
- Similar features to PG350 with electric lift towers and backrest, and locking casters.
- Powered motions include height adjustment and Trendelenburg/Reverse Trendelenburg.
- Table capacity is 550 lbs. (250 kg.).
Installation and Use
- Grounding instructions are provided for safe installation.
- Directions for use include control operations for various models and configurations.
- Safety features include a hand control safety lock-out and a central base locking system.
Cleaning and Maintenance
- Recommended cleaners and disinfectants are specified.
- Regular inspections are advised to ensure proper functioning.
Specifications
- Detailed product specifications, environmental conditions, and electrical specifications are provided.
- Guidance on electromagnetic emissions and immunity is included.
Control Operations
Multi-Specialty & Echocardiography with Electric Sliding Panel
- Do not sit on the Fowler (Backrest) or Leg Rest sections.
- Ensure nothing impedes motion when lowering the table or using Trendelenburg functions.
- Functions include height adjustment, Trendelenburg, and Fowler adjustments.
Vascular with Fowler
- Similar cautions with emphasis on using the Patient Restraint Strap.
- Functions include height adjustment, Trendelenburg, Fowler, and Vascular tilt.
Side Rail Use
- Instructions for raising and lowering side rails.
- Ensure rails are locked securely.
Detachable Arm Board and Retractable Foot Rests (Stirrup) Use
- Caution against excessive weight on the Arm Board.
- Instructions for adjusting and storing foot rests.
Adjustable Angle Back Support and Central Base Locking System
- Instructions for adjusting back support and locking the system.
- Caution against sitting on the back support.
Manual Adjustable Four Position Leg Rest Use
- Instructions for raising and lowering the leg rest.
- Caution against sitting on the leg rest.
Procedure Tray Use
- Ensure leg rest is fully lowered before using the tray.
- Maximum weight rating of 15 lbs.
Sliding Cardio Panel Use
- Instructions for manual and electric operation.
- Caution against excessive weight on the panel.
Integrated Foot Board Use
- Instructions for adjusting foot board positions.
- Ensure secure positioning before use.
Vascular Patient Restraining Strap Use
- Instructions for installing the strap on different table types.
Paper Roll Holder Use
- Instructions for loading and cutting paper.
Table Extender and QuickLock Face Rest Use
- Instructions for using the table extender and face rest.
- Caution against excessive weight on these components.
Patient Lift Compatible Base and T-Rail Adapter Use
- Instructions for using patient lifts and T-Rail adapters.
Cleaning & Disinfection
- Recommended and non-recommended cleaners and disinfectants.
- Emphasis on avoiding certain chemicals that can damage materials.
See more

Catalog excerpts

PG Series & Ultrasound Series-1

USER MANUAL PG Series & Ultrasound Series ULTRASOUND SERIES made in the USA with US & imported parts

 Open the catalog to page 1
PG Series & Ultrasound Series-2

Notice The information contained within this document is subject to change without notice and should not be construed as a commitment by OAKWORKS®, Inc. Printed in U.S.A. All rights are reserved. No part of this document may be photocopied, reproduced or translated to another language without prior written consent of OAKWORKS®, Inc. OAKWORKS® is a registered trademark of OAKWORKS®, Inc. OAKWORKS®, Inc. encourages requests for technical specifications and the like documentation to ensure accuracy. The appropriate documentation is available upon request. OAKWORKS®, Inc. shall not be liable for...

 Open the catalog to page 2
PG Series & Ultrasound Series-4

PRODUCT USE DESCRIPTION / IMPORTANT SAFETY INSTRUCTIONS PRODUCT USE DESCRIPTION The PG and Ultrasound Tables are used to support the patient during examinations and procedures. It is intended to be operated by a healthcare professional in a medical environment. No special training is required but a review of the following Safety Instructions is important for the safety of the operator and patient. The healthcare professional should read and understand this entire manual before use with a patient. There are no known contraindications to the use of this equipment. SYMBOL IDENTIFICATION This symbol,...

 Open the catalog to page 4
PG Series & Ultrasound Series-5

IMPORTANT SAFETY INSTRUCTIONS The use of accessories, transducers, and cables other than those specified by the manufacturer, may result in increased emissions or decreased immunity of the table. The table should not be used adjacent to or stacked with other equipment and that if adjacent or stacked use is necessary, the table should be observed to verify normal operation in the configuration in which it will be used. The table is designed to be a stand alone table used with hand held ultrasound probes. This table must not be modified or incorporated into any other equipment. As with any moving...

 Open the catalog to page 5
PG Series & Ultrasound Series-6

PRODUCT DESCRIPTION Manual 4 position leg rest STANDARD SPECIFICATIONS QuickLock Face Pad Accessory Mounting Plate (Fowler end only) Table Extender - 12" (30.5 cm.) Long For electrical specs, see Specifications section.

 Open the catalog to page 6
PG Series & Ultrasound Series-7

PRODUCT DESCRIPTION STANDARD SPECIFICATIONS QuickLock Face Pad Accessory Mounting Plate (Fowler end only) Table Extender - 12" (30.5 cm.) Long For electrical specs, see Specifications section.

 Open the catalog to page 7
PG Series & Ultrasound Series-8

PRODUCT DESCRIPTION STANDARD SPECIFICATIONS Side Rails (2) Hand Control - All powered motions Patient Lift Compatible Base T-rail Adapter QuickLock Face Pad Accessory Mounting Plate (per end) Table Extender - 12" (30.5 cm.) Long ACCESSORIES For electrical specs, see Specifications section.

 Open the catalog to page 8
PG Series & Ultrasound Series-9

PRODUCT DESCRIPTION General Shown with Optional Fowler (Back Rest) Paper roll holder (1) Upholstered Top Optional electric Fowler (1) hand control Electric Lift Towers (2) optional foot control STANDARD SPECIFICATIONS Powered 22”-38” (55.9-96.5 cm.) Height Range Electric Fowler Powered ±15º Trendelenburg/ Reverse Trendelenburg Manual 4 Position Leg Rest Hand Control 3 or 2 section General – Motions 1-3 1 section General – Motions 1 & 2 Sliding Cardio Panel - Electric or Manual (30” Width & Left side only) Paper Roll Holder Accommodates up to 21” (53.3 cm.) rolls (roll not included) Table Voltage...

 Open the catalog to page 9
PG Series & Ultrasound Series-10

PRODUCT DESCRIPTION Paper roll holder (1) Women's Imaging hand control Electric Fowler Adjustable angle back support (Right side is standard) Electronic Lift Towers (2) optional foot control For electrical specs, see Specifications section.

 Open the catalog to page 10
PG Series & Ultrasound Series-11

PRODUCT DESCRIPTION STANDARD SPECIFICATIONS T-rail Adapter QuickLock Face Pad Accessory Mounting Plate (Per end - Fowler end only on 3 section tables) Table Extender - 12" (30.5 cm.) Long For electrical specs, see Specifications section.

 Open the catalog to page 11
PG Series & Ultrasound Series-12

hand control Adjustable angle back support (Right side is standard) foot control - manual cardio foot control - electric cardio For electrical specs, see Specifications section.

 Open the catalog to page 12
PG Series & Ultrasound Series-13

PRODUCT DESCRIPTION Paper roll holder (1) Electric Fowler Patient Restraint Strap (1) hand control optional foot control For electrical specs, see Specifications section.

 Open the catalog to page 13
PG Series & Ultrasound Series-14

PRODUCT DESCRIPTION Paper roll holder (1) Patient Restraint Strap (1) Electronic Lift Towers (2) Integrated Foot Board (2)

 Open the catalog to page 14
PG Series & Ultrasound Series-15

INSTALLATION All tables come completely assembled and ready to use. Plug the cord into a functioning outlet that is rated for the table. (see Grounding below) Arrange the power cord and control cords so that they will not create a tripping hazard and where the controls are located to your liking and are conveniently accessible. Be sure access to plug is not blocked for disconnecting the table from power. Risk of Electric Shock - Connect this furnishing to a properly grounded outlet only. This product must be grounded. If it should malfunction or break down, grounding provides a path of least...

 Open the catalog to page 15
PG Series & Ultrasound Series-16

DIRECTIONS FOR USE CONTROL OPERATIONS - PG200 Do not sit on the Fowler (Backrest) or Leg Rest sections. Do not leave the patient unattended. When lowering the table or using the Trendelenburg functions, make sure there is nothing that can impede motion (like stools, cabinets, accessory parts, cleaners, etc.) The Foot Control and optional Hand Control operate all functions of the table with the touch of a button. Follow the directions below to access these functions. Reverse Trendelenburg: elevates tabletop Trendelenburg functions are preserved during elevation Height Down: lowers tabletop positioning...

 Open the catalog to page 16
PG Series & Ultrasound Series-17

DIRECTIONS FOR USE CONTROL OPERATIONS - PG350 & PG300 Do not sit on the Fowler (Backrest) or Leg Rest sections. Do not leave the patient unattended. When lowering the table or using the Trendelenburg functions, make sure there is nothing that can impede motion (like stools, cabinets, accessory parts, cleaners, etc.) optional hand control elevates tabletop Reverse Trendelenburg: Trendelenburg functions are preserved during elevation positioning stops when table is level; press again to continue. Trendelenburg: activates tilt up to 15º positioning stops when table is level; press again to continue...

 Open the catalog to page 17

All Oakworks catalogs and technical brochures

  1. Antigua

    28  Pages

  2. OAKWORKS

    32  Pages

  3. PORTAL LIGHT

    4  Pages

  4. libra

    2  Pages

  5. Masters

    15  Pages

  6. Spa Catalog

    44  Pages

  7. AURORA™

    32  Pages

  8. PROLUXE™

    32  Pages

  9. Symphony

    1  Page

  10. EQUINOX

    1  Page

  11. Trolley

    8  Pages

  12. Exam Tables

    20  Pages

  13. Powerline

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.