1. Catalogs
  2. Oakworks
  3. Clodagh Libra
video corpo

Clodagh Libra

Clodagh Libra
1 / 24 PagesView full catalog

Clodagh Libra

Product catalog summary
Symbol Identification
This section explains the symbols used in the manual, including caution, electrical shock hazard, and protective earth terminal, as well as symbols related to transport and storage conditions.
Warnings & Safety Instructions
Highlights the importance of reading all instructions to prevent injury. Key points include connecting the table to a Ground Fault Protected Outlet, avoiding use with damaged cords, and keeping electrical appliances away from the table. Specific warnings for the foot bath include risks of burns, drowning, and bacterial growth if not cleaned properly.
Grounding Instructions
Details the necessity of connecting the product to a properly grounded outlet to prevent electric shock, including instructions for testing the Ground Fault Circuit Interrupter (GFCI).
Product Description & Table Specifications
Describes the table's features, such as lift capacity, weight, dimensions, and electronic controls. The table includes a metal frame base, electric height adjustment, and optional padding and upholstery.
Installation & Leveling Instructions
The table is pre-assembled and requires connection to a GFCI outlet. Instructions for leveling the table on uneven floors using adjustable feet are provided.
Directions for Use
Includes instructions for adjusting the table's height and top, using side arm rests, and operating the QuickLock Face Rest and foot bath. Safety notes emphasize not exceeding weight limits and ensuring proper use of controls.
Care & Cleaning
Guidelines for cleaning the table and foot bath to maintain hygiene and functionality, emphasizing unplugging the table before cleaning.
Electrical Specifications & Warranty Information
Provides electrical specifications and outlines warranty coverage, emphasizing the importance of following safety and maintenance instructions to avoid voiding the warranty.
Specifications and Safety Instructions
Provides detailed instructions for the safe operation and maintenance of a multifunctional table, emphasizing not lifting the table by the tabletop to avoid damage. The table is equipped with a hand control for backrest and seat positioning, and a foot control for height adjustment. Users are cautioned to observe all warnings to prevent injury.
Operating Instructions
The table features a foot control for adjusting height and a hand control for backrest and seat positioning. The armrests adjust automatically but can be moved or removed for client access. Advises against placing excess weight on armrests or using them to assist clients on or off the table.
Storage and Accessory Use
The table includes an under-table shelf for storage, with a maximum load of 225 lbs, and a 110V accessory outlet with a maximum load of 1000 watts. The cabinet hood under the backrest is not for storage.
QuickLock™ Face Rest and Head Rest
The QuickLock™ Face Rest offers adjustable positioning for client comfort. It should not extend more than 3 inches from the table edge to ensure stability. Excessive weight on the face rest is discouraged to prevent damage.
Foot Bath Instructions
The foot bath should be filled with water 2 inches above the jet cover. Includes instructions for draining using a discharge pump, which must be connected to a GFCI outlet.
Moving the Table
The table weighs approximately 200 lbs and requires four people to move it safely. It should be lifted from the base corners, not the tabletop, to avoid damage.
Maintenance and Cleaning
To maintain the table's quality, use protective sheets and mild cleaning solutions. Avoid strong cleaners and extreme temperatures to prevent damage to the upholstery.
Care and Maintenance Instructions
  • Avoid exposing upholstery fabric to extreme temperatures and direct sunlight to prevent fading, cracking, and permanent stretching.
  • Use an anti-slip pad to prevent oil from reaching the upholstery and to keep sheets from slipping.
  • Clean metal and wooden surfaces with a mild, non-abrasive cleaner using a damp lint-free cloth. Ensure the unit is unplugged before cleaning.
  • No maintenance or lubrication is required for the table's electronic or manual powering mechanism.
  • If the table is unused for an extended period, unplug the power cord and secure it with a wire tie or rubber band.
  • Polish wooden cabinetry with approved polish, applying it with a soft cloth.
  • Periodically tighten bolts to ensure they remain secure.
  • Store face rest and table extender in a cool, dry place when not in use.
Foot Bath Cleaning Procedure
  1. Turn off the pedicure sink and drain the footbath.
  2. Remove jet assemblies and clean them with a non-abrasive antibacterial cleaner.
  3. Disinfect jet assemblies and footbath, allowing the disinfectant to set for one minute before rinsing and drying.
  4. Reassemble jet assemblies and secure them into position.

Use an EPA-registered cleaner/disinfectant with tuberculocidal, germicidal, pseudomonacidal, fungicidal, and virucidal efficacy.

Product Identification and Specifications
  • Power lead plugs are identified for different regions, including North America, Europe, Italy, Switzerland, the United Kingdom, and Australia.
  • Electrical specifications vary by region, with voltage and current service details provided for North America, Europe, and Japan/Korea.
  • Storage and transport conditions include temperature and humidity guidelines.
Warranty Information
  • Warranties cover factory-provided replacement parts, repair, or replacement at OAKWORKS® discretion.
  • Exclusions include damage from improper setup, misuse, neglect, and unauthorized repairs.
  • Warranties are voided by non-approved cleaning solutions and non-factory modifications.
  • Proof of purchase is required for warranty validation.
Contact Information

OAKWORKS® Inc., 923 East Wellspring Road, New Freedom, PA 17349. Toll-Free (USA only): 800-916-4613, Phone: 717-235-6807, FAX: 717-235-6798, Website: www.oakworks.com

See more

Catalog excerpts

Clodagh Libra-1

Libra INSTRUCTION www.oakworks.com · 717.235.6807 MANUAL ™

 Open the catalog to page 1
Clodagh Libra-2

© Copyright 2010 OAKWORKS® , Inc. Manual Part # MMMNST0020 1st Edition, May 2010 Printed in U.S.A. All rights are reserved. No part of this document may be photocopied, reproduced or translated to another language without prior written consent of OAKWORKS®, Inc. OAKWORKS® is a registered trademark of OAKWORKS®, Inc. Notice The information contained in this document is subject to change without notice and should not be construed as a commitment by Oakworks®, Inc. Oakworks®, Inc. assumes no responsibility for any errors that may appear in this document nor does it make expressed or implied warranty...

 Open the catalog to page 2
Clodagh Libra-4

SYMBOL IDENTIFICATION SYMBOL IDENTIFICATION SYMBOL IDENTIFICATION This symbol, when used in this manual and on product labels, represents a caution. Be sure to read and comply with all precautions and warnings. This symbol, when used in documentation on this product, indicates danger and warns against an electrical shock hazard. Be sure to observe and comply with all warnings and instructions. This symbol, when used in documentation on this product, indicates a Protective Earth (Ground) Terminal. This symbol when used in documentation on this product, warns that during transport there should...

 Open the catalog to page 4
Clodagh Libra-5

READ AND SAVE THESE INSTRUCTIONS WARNINGS / SAFETY WARNINGS & SAFETY INSTRUCTIONS IMPORTANT WARNINGS & SAFETY INSTRUCTIONS Improper use of this device can cause injury. Be sure to read all operating instructions prior to use to prevent injury to operator or client. DANGER Electrical Shock Hazard. • To reduce the risk of electric shock, always disconnect the table from the electrical outlet before moving the table or doing any maintenance or troubleshooting procedures. Never use this equipment if it has a damaged cord or plug. Use this equipment only for its intended use as described in these...

 Open the catalog to page 5
Clodagh Libra-6

WARNINGS & SAFETY INSTRUCTIONS WARNINGS / SAFETY READ AND SAVE THESE INSTRUCTIONS WARNINGS CONTINUED IMPORTANT WARNINGS & SAFETY INSTRUCTIONS This product is equipped with an interior accessory outlet (110V only). The total electrical load plugged into this set of outlets is not to exceed 1000 watts. • Risk of Injury – Children should never be near the table when in use. Remove ON-Off key when not in use. (if applicable) • Never drop or insert any object into any opening. • Risk of accidental injury or drowning. Exercise care when entering or exiting the foot bath. Invalid or disabled persons...

 Open the catalog to page 6
Clodagh Libra-7

READ AND SAVE THESE INSTRUCTIONS CAUTIONS WARNINGS / SAFETY WARNINGS & SAFETY INSTRUCTIONS WARNINGS WARNINGS & SAFETY INSTRUCTIONS • Be certain that the table is completely lowered prior to discharging an ambulatory patient. The patient may lose balance and fall. Do not leave clients unattended when table is set at its highest level. • The table weighs as much as 225 lbs. (102 kg.) DO NOT lift or move the unit without using proper safely procedures or equipment. DO NOT turn the table on its side for any reason. To do so could cause damage to the base and will void the warranty. There are no serviceable...

 Open the catalog to page 7
Clodagh Libra-8

WARNINGS & SAFETY INSTRUCTIONS (CONTINUED) GROUNDING INSTRUCTIONS GROUNDING & FOOT BATH CERTIFICATION GROUNDING INSTRUCTIONS CAUTIONS GROUND FAULT & GROUNDING INSTRUCTIONS The integral GFCI should be tested on a routine basis. To test the GFCI, push the test button. The GFCI should interrupt power. Push the reset button. Power should be restored. If the GFCI fails to operate in this manner, DO NOT USE THE UNIT. Disconnect the unit and have the problem corrected by a qualified service representative or an electrician before using. • This product must also be connected to a Ground Fault protected...

 Open the catalog to page 8
Clodagh Libra-9

PRODUCT DESCRIPTION PRODUCT DESCRIPTION PRODUCT DESCRIPTION Backrest top Manicure Arm rests (2) Powder Coated Steel Base PediBath Hydraulic Lift Columns (4) Storage shelf TABLE SPECIFICATIONS • Lift Capacity: 500 lbs. (226 kg.) • Weight: 200 lbs. (91 kg.) • Shipping Weight: 250 lbs. (114 kg.) • Shipping Box Dimensions: 81” L x 37” W x 31” H • Height Range: 25” - 33” (64-84 cm) • Width: 30” (76 cm) • Length: 77” (195 cm) • Top: Electronically Controlled Backrest Top • Base: Metal Frame Base with shelf and electric height adjustment • Electronics: 1 Hand Control & 1 Foot Control • Padding: 4” Aero·Cel™...

 Open the catalog to page 9
Clodagh Libra-10

INSTALLATION INSTALLATION INSTALLATION When operating the table’s controls be sure to observe all cautions and warnings given in the manual to prevent injury to both operator and client. ASSEMBLY & INSTALLATION INSTALLATION The table comes completely assembled and ready to use. Plug the cord into a functioning GFCI outlet that is rated for the table. Arrange the power cord and foot switch so that they will not create a tripping hazard. Place the controls in a safe location where they are convenient and accessible. Keep the controls out of the way of all table mechanisms. LEVELING INSTRUCTIONS...

 Open the catalog to page 10
Clodagh Libra-11

DIRECTIONS FOR USE CAUTION When operating the controls and making any and all adjustments to the table, move hands and feet away from the working mechanism of the table. ADJUSTING HEIGHT OF THE TABLE DIRECTIONS FOR USE DIRECTIONS FOR USE The table comes complete with a multi-functional hand control that operates the backrest and seat positioning functions as well as a foot control that operates the height with ease. Foot Control Operate the foot control as shown below to raise or lower the height of the table. When operating the table’s controls, be sure to observe all cautions and warnings as...

 Open the catalog to page 11
Clodagh Libra-12

DIRECTIONS FOR USE DIRECTIONS FOR USE ADJUSTING THE TOP Hand Control - 4 Positioning Buttons When operating the table’s controls be sure to observe all cautions and warnings given in the manual to prevent injury to both operator and client. The hand control operates all the positioning of the backrest and seat. Press and hold the appropriate button until the position desired is achieved and then release. The arm rests will adjust automatically to provide the most in comfort and ergonomics while staying parallel to the floor, no matter what the position. 1 Back Rest Control: CAUTION DO NOT sit...

 Open the catalog to page 12

All Oakworks catalogs and technical brochures

  1. Antigua

    28  Pages

  2. OAKWORKS

    32  Pages

  3. PORTAL LIGHT

    4  Pages

  4. libra

    2  Pages

  5. Masters

    15  Pages

  6. Spa Catalog

    44  Pages

  7. AURORA™

    32  Pages

  8. PROLUXE™

    32  Pages

  9. Symphony

    1  Page

  10. EQUINOX

    1  Page

  11. Trolley

    8  Pages

  12. Exam Tables

    20  Pages

  13. Powerline

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.