video corpo

HAVEN BROCHURE
11Pages

{{requestButtons}}

Catalog excerpts

HAVEN BROCHURE - 1

HAVEN SUPPLY AND EXTRACT TERMINALS SPECIFICATION GUIDE

Open the catalog to page 1
HAVEN BROCHURE - 2

HAVEN SUPPLY AND EXTRACT TERMINALS SELECTION GUIDE PROUD TO BUILD BRITISH GOING FURTHER TO CREATE HEALTHY BUILDINGS INTRODUCING HAVEN SUPPLY AND EXTRACT TERMINALS We’ve been pioneers in new air technology since 1966. Our heritage is in the design and manufacture of fans and ventilation systems. We put our energy into efficient ventilation so you don’t waste yours. THE HAVEN SUPPLY AND EXTRACT TERMINALS STANDARD TERMINAL QUANTITY DISTRIBUTION DUCTWORK TERMINAL RESISTANCE SUPPLY TERMINAL RESISTANCE EXTRACT TERMINAL SPECIFICATION GOING FURTHER TO CREATE HEALTHY BUILDINGS A well-designed...

Open the catalog to page 2
HAVEN BROCHURE - 3

HAVEN SUPPLY AND EXTRACT TERMINALS SELECTION GUIDE INTRODUCING HAVEN SUPPLY AND EXTRACT TERMINALS Haven Supply and Extract Terminals overcome challenges often encountered when ensuring all occupants receive the right supply of fresh air, even when building layouts are changed. With occupant health and well-being at the core of our thinking, Haven Supply and Extract Terminals have been developed to allow the provision of the best air quality possible for each individual – without resorting to extremes of personnel segregation. This led us to consider how we could set new industry standards...

Open the catalog to page 3
HAVEN BROCHURE - 4

HAVEN SUPPLY AND EXTRACT TERMINALS SELECTION GUIDE TERMINAL QUANTITY GENERAL CONCEPT GENERAL OFFICE / CALL CENTRE INDIVIDUAL OFFICE HIGH DENSITY CALL CENTRE The illustrations below represent typical systems found in work and public spaces – with each occupant’s location considered. We can apply the overall concept to other room types and layouts. The Haven Supply and Extract Terminals supply air terminal (HTS) range offers a number of formats based on nominally providing one directionally adjustable supply outlet (SO) per individual occupant. Haven Supply and Extract Terminals create a...

Open the catalog to page 4
HAVEN BROCHURE - 5

HAVEN SUPPLY AND EXTRACT TERMINALS SELECTION GUIDE DISTRIBUTION DUCTWORK TERMINAL RESISTANCE - SUPPLY The configurable distribution ductwork is both cost effective and convenient. Additionally, it may be possible to re-use existing systems, further reducing costs*. The Haven Supply and Extract Terminals unit shall be designated according to the following coding protocol. HAVEN T Supply / Extract Filter Grade SUPPLY DISTRIBUTION DUCT EXAMPLE TERMINAL RESISTANCE CURVE 10l/s 250mm dia duct - Max velocity < 4m/s - Operating pressure** Air Volume Flow Rate (l/s) In practice, this simply means...

Open the catalog to page 5
HAVEN BROCHURE - 6

HAVEN SUPPLY AND EXTRACT TERMINALS SELECTION GUIDE TERMINAL RESISTANCE - SUPPLY TERMINAL RESISTANCE - EXTRACT TERMINAL RESISTANCE CURVE The Haven Supply and Extract Terminals unit shall be designated according to the following coding protocol. HAVEN T Supply / Extract Filter Grade Air Volume Flow Rate (l/s) HTE 1 Air Volume Flow Rate (l/s) HTS9 Air Volume Flow Rate (l/s) AIR TREATMENT Haven Supply Terminals shall optionally be supplied with an integral air / air filter treatment module. TERMINAL RESISTANCE CURVE AIR VOLUME FLOW RATE (l/s) The module shall consist of a high intensity UV-C...

Open the catalog to page 6
HAVEN BROCHURE - 7

HAVEN SUPPLY AND EXTRACT TERMINALS SELECTION GUIDE TERMINAL SPECIFICATION SPECIFICATION Haven T S 4/9/12 Supply Terminal GENERAL The Haven Supply Terminal shall be suitable for supply ventilation rates of 40 – 120 l/s* via the specified quantity of independent supply ports, each with 360 degree directional adjustability. The air shall be discharged from each port at an initial velocity not exceeding 1.5 m/s, and at an initial angle of 45 degrees from the horizontal. The terminal shall include means of flow equalisation. The non-combustible terminal housing shall be constructed from heavy...

Open the catalog to page 7
HAVEN BROCHURE - 8

HAVEN SUPPLY AND EXTRACT TERMINALS SELECTION GUIDE DIMENSIONAL DRAWINGS EXTRACT TERMINAL HTE1/2/3 HORIZONTAL FACIA EXTRACT TERMINAL HTE1/2/3 DIAGONAL FACIA By using fine particulate or chemical filters in the Haven Terminal unit or in the Haven inline filter module, treatment is provided for residual external and system-based contaminants to the greatest practical extent. Haven Supply and Extract Terminals provide an efficient means of providing high specification filtration to provide maximum protection to the building occupants. Classification of contaminants and selection criteria for...

Open the catalog to page 8
HAVEN BROCHURE - 9

HAVEN SUPPLY AND EXTRACT TERMINALS SELECTION GUIDE SUPPLY AIR CLASSIFICATION As a starting point, the following approach is suggested. UP 1 applies where the supply of air fulfils the WHO (2005) guidelines limit values S and any National air quality standards limit values or regulations with a factor x0,25. UP 2 applies where the supply of air fulfils the WHO (2005) guidelines limit values S and any National air quality standards limit values or regulations with a factor x0,5. UP 3 applies where the supply of air fulfils the WHO (2005) guidelines limit values S and any National air quality...

Open the catalog to page 9
HAVEN BROCHURE - 10

HAVEN SUPPLY AND EXTRACT TERMINALS SELECTION GUIDE

Open the catalog to page 10
HAVEN BROCHURE - 11

COMMERCIAL WWW.NUAIRE.CO.UK/COMMERCIAL RESIDENTIAL WWW.NUAIRE.CO.UK/RESIDENTIAL INTERNATIONAL WWW.NUAIRE.CO.UK/INTERNATIONAL WESTERN INDUSTRIAL ESTATE | CAERPHILLY | CF83 1NA T 029 2085 8200 F 029 2085 8300 E INFO@NUAIRE.CO.UK WWW.NUAIRE.CO.UK

Open the catalog to page 11

All Nuaire catalogs and technical brochures

  1. EXTRACT FANS

    20 Pages

  2. BESPOKE BOXER

    15 Pages

  3. XBOXER XBC

    60 Pages

  4. Smoke fans

    54 Pages

  5. Twin fans

    62 Pages

  6. OEM solutions

    14 Pages

Archived catalogs

  1. OEM