Product Overview

The document details the specifications and installation requirements for the NEXIS R90 multifunction complete steam cubicle featuring a quadrant design with 2 sliding doors and 2 fixed panels. It includes various models with different finishes, dimensions, and mixer types.

Product Codes and Finishes

  • Dimensions: 90x90 cm, with shower tray heights of 8 cm or 15 cm.
  • Available finishes include Wood White, Grain White Oak, Burlington Ash, and Wenge.
  • Two mixer types: HYDRO (thermostatic) and HAMMAM (thermostatic).
  • Product codes are constructed based on dimensions, finish, and mixer type (e.g., NEXR90T1F-1K).

Technical Specifications

Dimensions

  • Overall height ranges from 209 cm to 234 cm depending on model and shower tray height.
  • Access width is consistently 48 cm.
  • Shower tray options include 80 mm and 150 mm heights with detailed dimensional tables for models A90, R90, A100x80, and A120x80.

Materials

  • Back wall thickness: 8 mm.
  • Glass panels: 5 mm thickness.

Hydraulic Characteristics

  • Optimal dynamic water pressure: 2 to 5 bar.
  • Hot and cold water connections: 1/2 inch.
  • Drain connection diameter: 40 mm.

Electrical Characteristics

  • Supply voltage: 220 - 230 V.
  • Frequency: 50/60 Hz.
  • Maximum absorbed power: 2500 W.
  • Maximum line current: 2600 W.
  • Installation requires a 30mA differential switch upstream with a multiple-pole switch having a minimum contact opening of ≥ 3 mm.

Installation and Safety Requirements

  • Ensure recirculated air in the bathroom is guaranteed for proper ventilation.
  • Minimum clearance of 40 cm around the cubicle is recommended.
  • Use of an imperial to metric flex waste adaptor (code RISCCAB) is compulsory.
  • Warning: Installation of a 30mA differential switch is mandatory for electrical safety.
  • Warning: The steam cubicle may be dangerous for pacemaker wearers.

Additional Notes

  • Visual inspection of some components is not possible after installation.
  • Left and right versions are available for certain models (codes S for left, D for right).
  • Check product availability before ordering.

Summary of Critical Parameters

ParameterValue / Range
Supply Voltage220 - 230 V
Frequency50/60 Hz
Max Power Absorbed2500 W
Water Pressure2 - 5 bar
Water Connections1/2 inch hot and cold
Drain Diameter40 mm
Minimum Clearance40 cm
Access Width48 cm
Shower Tray Heights80 mm or 150 mm

Conclusion

The NEXIS R90 steam cubicle is a versatile bathroom fixture designed with safety and functionality in mind. Proper electrical installation and ventilation are critical. The product offers multiple configurations to suit different bathroom layouts and aesthetic preferences. Users with pacemakers should avoid use due to safety concerns.

See more

Catalog excerpts

NEXIS R90-1

®®€>® 200 cm 5 mm 8 mm Back wall MULTIFUNCTION COMPLETE STEAM CUBICLE - QUADRANT - 2 SLIDING DOORS + 2 FIXED PANELSI ^ A I) Compulsory Imperial to Metric flex waste adaptor Code Please check availability ^= Final product Code

 Open the catalog to page 1
NEXIS R90-3

NEXIS Shower tray 80 mm TECHNICAL DATA A90 TECHNICAL DATA AWARNING! It could be dangerous for pacemaker wearer WARNING! Install a 30mA differential switch upstream of the appliance with a multiple-pole switch with a minimum contact opening > 3 mm. HYDRAULIC CHARACTERISTICS: Optimal dynamic pressure 2-5 bar Hot water 1/2" I Cold water 1/2" Drain connection 0 40 mm ELECTRICAL CHARACTERISTIC: Supply voltage 220 - 230 V Frequency50/60 Hb Max. Leitungsaufnahme: 2600 W Maximum absorbed power: 2500 W

 Open the catalog to page 3
NEXIS R90-4

NEXIS Shower tray 150 mm TECHNICAL DATA for model Left version Right version A90 - R90 for model A100x80 - A120x80 HYDRAULIC CHARACTERISTICS: Optimal dynamic pressure2-5 bar Hotwater 1/2' Cold water 1/2' Drain connection 0 40 mm ELECTRICAL CHARACTERISTIC: Supply volt age 220 - 230 V Frequency 50/60 Hz Max. Leitungsaufnahme: 2600 W Maximum absorbed power: 2500 W WARNING! Install a 30mA differential switch upstream of the appliance with a multiple-pole switch with a minimum contact opening > 3 mm.

 Open the catalog to page 4

All NOVELLINI catalogs and technical brochures

  1. H STYLE

    2  Pages

  2. STYLE C

    5  Pages

  3. HP ART

    2  Pages

  4. HC ART

    2  Pages

  5. OLYMPIC PLUS

    2  Pages

  6. NOVOSOLID

    3  Pages

  7. STYLE

    8  Pages

  8. ROSE PH+F

    4  Pages

  9. BRERA G+F

    3  Pages

  10. LUNES 2.0 B

    4  Pages

  11. Gala H

    2  Pages

  12. LUNES 2.0 R

    2  Pages

  13. LUNES 2.0 2P

    5  Pages

  14. Opera 2PH

    3  Pages

Archived catalogs

  1. LUNES 2.0 A

    3  Pages

  2. Opera 2P+F

    3  Pages

  3. BRERA G

    3  Pages

  4. ROSE A

    3  Pages

  5. SENSE DUAL

    6  Pages

  6. ROSE PHB

    2  Pages

  7. Opera 2A

    3  Pages

  8. Opera PH+FH

    2  Pages

  9. Young 2.0 2B

    10  Pages

  10. Kuadra A

    3  Pages

  11. SKILL A100X80

    4  Pages

  12. OLYMPIC PLUS

    2  Pages

  13. Kuadra 2P+F

    4  Pages

  14. Kuadra R

    2  Pages

  15. EON A90

    4  Pages

  16. SENSE 1

    2  Pages

  17. SOLE

    7  Pages

  18. CUSTOM

    2  Pages

  19. Aurora 1

    6  Pages

  20. Candida

    5  Pages

  21. Cristallo

    1  Page

  22. Go 2

    10  Pages

  23. Go 1

    10  Pages

  24. Walk 2

    10  Pages

  25. Vision R

    5  Pages

  26. VOGUE

    6  Pages

  27. CUSTOM

    3  Pages

  28. CUSTOM TOUCH

    5  Pages

  29. LUNES 2P

    4  Pages

  30. Lunes A

    6  Pages

  31. Giada R

    6  Pages

  32. Kuadra 2A

    6  Pages

  33. LOW PROFILE

    13  Pages

  34. Giada

    6  Pages

  35. Walk 1

    10  Pages

  36. Walk 3

    10  Pages

  37. N18† 1B

    3  Pages

  38. Free1 A

    6  Pages

  39. Louvre A

    6  Pages

  40. VISION

    7  Pages

  41. LOUVRE

    5  Pages

  42. OLYMPIC

    5  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.