NV-GLU

NV-GLU

NV-GLU

Product catalog summary
General Information
The NV-GLU is a water-based acrylic adhesive designed for permanent installation of Novalis vinyl floor coverings. It is moisture and alkalinity resistant, easy to clean, and does not damage the flooring surface. It is available in 1 and 4-gallon pails, features low VOC emissions, and is certified by FloorScore and CRI Green Label Plus.
Technical Specifications
  • Unit Sizes: 1 Gallon (17 lbs), 4 Gallon (31.97 lbs)
  • Base Polymer: Acrylic
  • Color/Consistency: Beige Paste with Green Tracers
  • pH: 7.25
  • VOC Emissions: < 1 g/l
  • Coverage Rate: 125-250 sq. ft. per gallon, 500-1000 sq. ft. per 4-gallon pail
  • Open/Flash Time: 15-30 minutes
  • Working Time: 4 hours
  • Shelf Life: 2 years
  • Storage Temperature: 40°-90°F
Installation Guidelines
  • Site Conditions: Ensure the area is enclosed and weathertight, with temperatures between 60°F and 80°F and humidity between 35% and 65%.
  • Substrate Preparation: Substrates must be clean, dry, flat, and free of contaminants. Concrete substrates should be at least 28 days old and free of moisture.
  • Tools Required: PPE, floor buffer, HEPA-filtered vacuum, adhesive trowel, 100 lb. roller, infrared thermometer.
Product Limitations
Do not install in outdoor conditions or over substrates with contaminants or excessive moisture. Avoid unsuitable substrates like hardwood, carpet, or any with visible mold or mildew.
Adhesive Installation
  • Trowel Use: Use specified trowel notch for even coverage. Replace trowels every 4 gallons.
  • Adhesive Acclimation: Ensure adhesive and floor covering are at the same temperature before installation.
Warnings and Recommendations
Follow all local, state, and federal regulations, especially regarding asbestos and lead. Document site conditions and test results for warranty purposes. Avoid using solvent or citrus-based adhesive removers.
Adhesive Application Procedure
Apply adhesive to one side of the starting line at a time, using a specified trowel notch at a ~45° angle. Ensure even application without skips or puddles. Allow 15-30 minutes for the adhesive to dry to the touch before installing flooring. Roll completed areas with a 100 lb. roller to ensure proper bonding.
Clean Up
Remove adhesive from surfaces immediately with a damp cloth. For dried adhesive, use 70% Isopropyl alcohol.
Protection & Traffic Restrictions
Allow immediate foot traffic but prevent heavy traffic for at least 12 hours. Use protective measures when moving heavy objects.
Warranty
Novalis adhesives are covered under the warranty for Novalis floor coverings. No warranty is provided for use with non-Novalis products.
Note
For professional use only. Review all technical and safety documents before installation.
See more

Catalog excerpts

NV-GLU-1

NV-GLU Technical Data & Installation Technical Data & Installation General Information The Novalis NV-GLU is a specially formulated acrylic adhesive used for the permanent installation of Novalis glue down vinyl floor coverings. The NV-GLU is waterbased, easy to apply and incredibly strong. The NV-GLU Adhesive Features The NV-GLU is easy to clean up, wet or dry, and will not mar or etch the surface of floor covering. Technical Information Unit Sizes: Excellent Initial Grab Excellent Shear Strength is also resistant to high levels of moisture and alkalinity, whether topical or from the substrate. Unit Weight: Base Polymer: Color / Consistency: Coverage Rate / 4 Gallon Pail: Open/Flash Time: Light Foot Traffic Limit: 125 - 250 sq. ft. (depending on trowel) 500 - 1000 sq. ft. (depending on trowel) 15 - 30 minutes (dry to touch) 4 hours Immediate 12 Hours Heat Welding: FloorScore Certified Shelf Life: Acclimation / Installation Temperature: CRI Green Label Plus Certified Installation Humidity: Spread Rate Chart Trowel Size Heavy Foot Traffic / Rolling Loads: Beige Paste w/ Green Tracers ASTM D7149 Freeze Thaw: Will Not Mar or Discolor Flooring Coverage Rate / Gallon: ■ 1 Gallon & 4 Gallon Pails Product Limitations Spread Rate 175 - 200 sq. ft. per gallon All published times and coverage rates are subject to substrate conditions, such as porosity and flatness, and ambient conditions, such as ambient air temperature, relative humidity and substrate temperature. Actual times and coverage rates may vary. For indoor use only - do not install in outdoor conditions. Do not install if ambient temperatures and humidity levels are outside of prescribed range or if conditions have reached dew point. Do not install adhesive over substrates which contain known or obvious contaminants, excessive moisture or hydrostatic pressure. Adhesives cannot resist extreme dimensional instability of flooring materials, which may cause gapping, cupping, buckling and/or edge lifting. Do not install over existing materials without consulting the substrate preparation guidelines. For information on the correct trowel to use, see the flooring installation instructions. Using an unspecified trowel may affect the adhesive coverage and adhesion to the flooring or substrate. Novalis International | P: (888) 509 - 3438 | novalis-intl.com |

 Open the catalog to page 1
NV-GLU-2

Technical Data & Installation 1. GENERAL INFORMATION Receiving Material & Storage: Remove all plastic and strapping from the product after delivery. Confirm that the adhesive is approved for use with the flooring, especially in the event you’ve received more than one. Carefully check all materials for shipping damage and note all damage on the bill of lading before accepting the delivery. Material accepted with visible shipping damage that is not reported on the bill of lading will not be covered under warranty. The floor covering and adhesive must be stored in dry indoors conditions between...

 Open the catalog to page 2
NV-GLU-3

Technical Data & Installation retarder that is compliant with ASTM E1745 installed directly beneath the slab. Moisture and pH tests are not usually required. Concrete Moisture Mitigation Requirements: When appropriate, use a dimensionally stable, surface-applied moisture mitigation system that, when tested in accordance with ASTM E96 / E96M Standard Test Methods for Water Vapor Transmission of Materials (Method B), has a permeability value of ≤ 0.1 grains/sq. ft./hr.. Confirm compliance with the manufacturer before use. Gypsum/Lightweight Substrate Requirements: Gypsum or Lightweight substrates...

 Open the catalog to page 3
NV-GLU-4

Technical Data & Installation Adhesive Acclimation: Check the temperature of the floor covering and adhesive using a non-contact, infrared thermometer - the temperature of both materials must be the same as the inservice temperature (± 2° F) before installation. Application: Only apply as much adhesive as can be covered within the working-time (4-hours), typically to only one side of your starting line at a time. Apply the adhesive slowly and evenly to the substrate at a ~45° angle using the specified trowel notch. Avoid skips, puddles or sharp trowel turns. Allow 15-30 minutes of open time for...