1. Catalogs
  2. Nilan A/S
  3. VPM 600 3200 brochure

VPM 600 3200 brochure

VPM 600 3200 brochure
1 / 24 PagesView full catalog

VPM 600 3200 brochure

Product catalog summary
Overview: The Nilan VPM 600-3200 series is a comprehensive commercial ventilation solution that integrates active heat recovery and cooling. It is designed for modern industrial buildings, especially those with large glass areas, providing efficient heating and cooling while maintaining a healthy indoor climate.
Specifications: The VPM series features a reversible cooling/heating system with outputs up to 35,000 m³/h and a high temperature efficiency of 94-98% due to its heat pump and heat pipe technologies. It uses the environmentally friendly refrigerant R744.
Benefits: Key benefits include reduced energy consumption and carbon emissions, easy installation with a modular structure, and user-friendly control via the Nilan CTS 6000 system, which allows for online monitoring and control.
Control and Monitoring: The CTS 6000 system enables remote control and monitoring via the internet, supports automatic operation with customizable programs, and provides alerts for operational failures and maintenance needs.
Installation and Start-up: Nilan offers a start-up and adjustment service to ensure optimal performance, including functional testing and adjustment of the CTS according to customer requirements.
Operational Economy: The Nilan Calculator software helps assess the operational economy of the units based on local climatic conditions, aiding in making informed decisions about economical ventilation solutions.
Technical Data: Detailed technical specifications are provided, including air volume capacities, weight, supply voltage, and sound levels for different models within the VPM series.
Performance Data: The document includes graphs and tables showing cooling and heating performance at various temperatures, sound levels at different frequencies, and pressure drops across the system.
Sound Levels: Sound levels are detailed for different air volumes and frequencies, crucial for assessing environmental impact.
Installation and Materials: Units are designed with self-supporting structures made from Alu-Zink, with options for various filters, hot water coils, and frequency-regulated compressors for energy efficiency.
Additional Features: Optional features include vibration dampers, electric heat coils, and fan frequency regulation, customizable based on installation needs.
Conclusion: Nilan VPM units are versatile systems designed for efficient ventilation and heating, with customizable options to suit different installation needs. The detailed technical data and performance metrics are essential for selecting the appropriate model for specific applications.
See more

Catalog excerpts

VPM 600 3200 brochure-1

Nilan VPM 600-3200 Active heat recovery and cooling (air/air)

 Open the catalog to page 1
VPM 600 3200 brochure-2

Nilan VPM 600-3200 Commercial ventilation with heat recovery and cooling How do you combine ventilation, heat recovery and cooling in one unit? Modern industrial buildings with large areas of glass make substantial demands on a ventilation unit. The unit must actively contribute to both heating and cooling of the building. In all Nilan’s industrial ventilation units, heat recovery and cooling have been considered from the outset. Our intelligent units work in harness with changes in the day, season and weather, minimizing operating costs while at the same time ensuring a healthy, stable indoor...

 Open the catalog to page 2
VPM 600 3200 brochure-3

By installation of an additional heat exchanger is it possible to recover the heat from the cooling process for domestic hot water production Wide range of accessories and add-ons Hermetically sealed refrigerant circuits, no special cooling authorisation required for fitting Easy, service-friendly access to all components Passive pre-heat-exchange of air via the built-in heat-pipe, based on an environmentally friendly refrigerant Easy to fit modular structure - everything is delivered plug and play Reversible modulating cooling circuit and heat recovery in one module Effectively insulated, self-supporting...

 Open the catalog to page 3
VPM 600 3200 brochure-4

Online control and monitoring of Nilan VPM 600-3200 CTS 6000 enables Nilan industrial units to be controlled and monitored online using a computer located anywhere in the world. CTS 6000 has been designed to meet future requirements for optimizing the economy of ventilation units as well as detailed adaptation to the requirements of individual buildings. Control Optimum control of ventilation units assumes simple and user-friendly operation of the most important functions. Using a weekly or annual programme, units can be set for automatic operation to allow for the setting of operating times,...

 Open the catalog to page 4
VPM 600 3200 brochure-5

Calculating operational economy A precise analysis of weather conditions and geographical location are decisive when choosing the most efficient and economically viable ventilation unit. Nilan has developed unique calculation software, The Nilan Calculator, which allows you to carry out realistic and extremely precise calculations that take every factor into account. Obtain a precise calculation of operational economy Whereas traditional calculation methods only take into account the units efficiency by extreme temperatures, Nilan’s software is based on data that presents a straightforward, precise...

 Open the catalog to page 5
VPM 600 3200 brochure-6

VPM capacity diagram Unit 16°C

 Open the catalog to page 6
VPM 600 3200 brochure-7

Nilan brings fresh air and well-being into every room Winter: Summer: Air volume of 25 % (relative to the nominal air volume), where the shown incoming air temperatur is maintained by capacity regulation of the heat pumps performance. Incoming air temperature at nominal air volume and nominal output at heat pump/cooling circuit. Air volume at an air temperature of 21°C is achieved without after-heat and maximum compressor power.

 Open the catalog to page 7
VPM 600 3200 brochure-8

Nilan VPM 600Technical DataSpecifications Air volume Installation with self-supporting structure. Materials: 1 and 1.5 mm Alu-Zink. * May differ according to configuration of compressors and fans. Sound Resulting sound level, Lw (dB) 21° indoor temperature, 50% RH, air volume 6.000 m3/h. Capacity graph Pt External pressure drop [Pa] Cooling performance 21° indoor temperature, 50% RH, air volume 6.000 m3/h. VPM cooling performance Compressor output

 Open the catalog to page 8
VPM 600 3200 brochure-9

Dimensional sketch Gable end with a filter and fan Recommended service clearan

 Open the catalog to page 9
VPM 600 3200 brochure-10

Nilan VPM 700Technical DataSpecifications Air volume Installation with self-supporting structure. Materials: 1 and 1.5 mm Alu-Zink. * May differ according to configuration of compressors and fans. Sound Resulting sound level, Lw (dB) 21° indoor temperature, 50% RH, air volume 7.000 m3/h. Capacity graph Pt External pressure drop [Pa] Cooling performance 21° indoor temperature, 50% RH, air volume 7.000 m3/h.

 Open the catalog to page 10
VPM 600 3200 brochure-11

Dimensional sketch Built-in evaporator and heat pipe Recommended service clearanc

 Open the catalog to page 11
VPM 600 3200 brochure-12

Nilan VPM 800Technical DataSpecifications Air volume Installation with self-supporting structure. Materials: 1 and 1.5 mm Alu-Zink. * May differ according to configuration of compressors and fans. Sound Resulting sound level, Lw (dB) 21° indoor temperature, 50% RH, air volume 8.000 m3/h. Capacity graph Pt External pressure drop [Pa] Cooling performance 21° indoor temperature, 50% RH, air volume 8.000 m3/h.

 Open the catalog to page 12
VPM 600 3200 brochure-13

Dimensional sketch Recommended service clearanc

 Open the catalog to page 13
VPM 600 3200 brochure-14

Nilan VPM 1000Technical DataSpecifications Air volume Installation with self-supporting structure. Materials: 1 and 1.5 mm Alu-Zink. * May differ according to configuration of compressors and fans. Sound Resulting sound level, Lw (dB) 21° indoor temperature, 50% RH, air volume 10.000 m3/h. Capacity graph Pt External pressure drop [Pa]

 Open the catalog to page 14
VPM 600 3200 brochure-15

Dimensional sketch Hermetic closed cooling circuit Recommended service clearanc

 Open the catalog to page 15
VPM 600 3200 brochure-16

Nilan VPM 1200Technical DataSpecifications Air volume Installation with self-supporting structure. Materials: 1 and 1.5 mm Alu-Zink. * May differ according to configuration of compressors and fans. Sound Resulting sound level, Lw (dB) 21° indoor temperature, 50% RH, air volume 12.000 m3/h. Capacity graph Pt External pressure drop [Pa] Cooling performance 21° indoor temperature, 50% RH, air volume 12.000 m3/h.

 Open the catalog to page 16
VPM 600 3200 brochure-17

Dimensional sketch Recommended service clearanc

 Open the catalog to page 17
VPM 600 3200 brochure-18

Nilan VPM 1500Technical DataSpecifications Air volume Installation with self-supporting structure. Materials: 1 and 1.5 mm Alu-Zink. * May differ according to configuration of compressors and fans. Sound Resulting sound level, Lw (dB) 21° indoor temperature, 50% RH, air volume 15.000 m3/h. Capacity graph Pt External pressure drop [Pa] Cooling performance 21° indoor temperature, 50% RH, air volume 15.000 m3/h.

 Open the catalog to page 18
VPM 600 3200 brochure-19

Nilan VPM 1500 Dimensional sketch Built-in mixing circuit for water heating surface

 Open the catalog to page 19
VPM 600 3200 brochure-20

Technical Data Total weight Weight of filter/fan section Resulting sound level, Lw (dB) Air volume 22.000 m³/h 250 Pa, + Tolerance +/- 3 dB Inlet Weight of centre module Supply voltage Refrigerant Heat Pump Filler volume Heat Pump Refrigerant heat pipe Filler volume heat pipe Isolation thickness Installation with self-supporting structure. Materials: 1 and 1.5 mm Alu-Zink. * May differ according to configuration of compressors and fans. Heating 21° indoor temperature, 50% RH, air volume 22.000 m³/h. VPM + HP heat output Compressor output Capacity graph Pt External pressure drop [Pa] Pressure...

 Open the catalog to page 20

All Nilan A/S catalogs and technical brochures

  1. VP 18 M2

    16  Pages

  2. EM-BOX

    4  Pages

  3. Indoor Climate

    36  Pages

  4. Compact p

    16  Pages

  5. Comfort 600

    8  Pages

  6. Comfort 450

    8  Pages

  7. Comfort 300

    8  Pages

  8. CTS 6000

    4  Pages

  9. Comfort CT300

    8  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.