Catalog excerpts
PRODUCT DATA | Passive House Institute | OUTSTANDING INDOOR CLIMATE
Open the catalog to page 1The ventilation and heating solution of the future Compact P is our latest addition to our range of energy efficient ventilation and heat pump solutions developed for the homes of the future. The system can be used in all types of low-energy and passive house constructions, but can also be used in standard houses and apartments with moderate energy consumption. very low costs for production of sanitary hot water. The ground source heat pumps, which can be fully integrated, have been designed with the latest compressor technology which ensures that heat output can continuously be adapted to...
Open the catalog to page 2Standard components 180-litre SHW tank with electric auxiliary heating Humidity sensor Sacrificial anode with alarm function Filter monitor Hermetically sealed refrigerant circuit Built-in water trap Circulation pipe for sanitary hot water Integrated circulation pump (outside part) Electric auxiliary heating 2 x 2 kW Dirt filter (central heating circuit) Heat pump module outside part (air/liquid) Pressurised expansion tank (central heating circuit) Manometer (central heating circuit) Safety valve (central heating circuit) Control LMC 223, heat pump Variable compressor Heat pump module...
Open the catalog to page 3Passive heat recovery Active heat recovery Sanitary hot water production Comfort cooling Comfort heating Product description Compact P is a passive house and energy-efficient total indoor climate solution for homes with a ventilation requirement of up to 325 m3/h. Compact P can be used in all types of low-energy houses, standard one-family houses, flats and small office areas in commercially leased premises, where easy installation is required, and where the focus is on an optimum indoor climate and minimum energy consumption. As standard, Compact P is built up with integrated CTS 602...
Open the catalog to page 4Planning data SEL values in accordance with EN 13141-7 are for standard unit with G4 filters and exclusive heating element. Max. Pa capacity of standard unit, pt,ext as a function of qv SEL values contain the unit’s total electricity consumption for fans, including control with 40% deduction for exchangers in accordance with BE10 Temperature efficiency Temperature efficiency nt according to EN 308 as a function af volume flow qv. Extract air t11 = 25 °C, fresh air t21=5 °C (dry). Heat output supply air Heat output Qc [W] as a function of qv [m3/h] and outdoor air temperature t21 [°C]. In...
Open the catalog to page 5Planning data Tapped water Tapped volume in litres Vmax [L] from Compact P tank as a function of tapped temperature t [C°] and tank temperature at 40°, 50° and 60°C 50°C tank 60°C tank 40°C tank 50°C tank Heat output factor COP [-] and heat output Qw for sanitary hot water as a function of the volume flow qv [m3/h] at a tank temperature of 41°C and room temperature t11 = 20°C, outdoor temperature t21 = 20°C in accordance with EN 255-3. Sound data Sound output level (Lwa) Sounddata is for qv = 210 m /h and Pt, ext = 100 Pa in accordance with EN 9614-2 for surface and EN 5136 for ducts. 3 At...
Open the catalog to page 6The functionality of your system can be widened with the right accessories. Choose between a wide range of equipment that utilises the great potential of the Compact P systems to the full. Electric heating element Electric pre-heating element A simple, inexpensive and flexible air distribution system which distributes the air that is drawn into the home in a minimal space. NilAIR can be installed in floors, walls or ceilings. With an electric heating element, the temperature of the air being drawn into the home can be further increased. the electric heating element is for integration in the...
Open the catalog to page 7Passive heat recovery Active heat recovery Sanitary hot water production Comfort cooling Comfort heating Product description The Compact P UVP solution has the same advantages and functions as Compact P, but additionally has an integrated air/water heat pump with connection to the home’s low temperature central heating system. The solution consists of an integrated inside part in Compact P as well as an outside part which is easy to connect. The very best components have been used to ensure stable and low noise operation as well as a high COP value and output – even on very cold days. All...
Open the catalog to page 8Dimensional drawing All dimensions are in mm Inside unit for Compact P UVP 1. Integrated circulation pump inside/outside part Med UVP5 Compact 2. Buffer tank 50 litres 3. Electric auxiliary heating 2 x 2 kW 4. Pressurised expansion tank (central heating circuit) 5. Manometer (central heating circuit) 4 3 6. Safety valve 2.5 bar (central heating circuit) 7. Dirt filter 8. Anode Base 1. Flow central heating 2. Flow UVP outside unit 3. Return UVP outside unit 4. Return central heating Integreret cirkulationspumpe (Indedel/Udedel) Bufferbeholder 50 liter El supplering 2x2kW....
Open the catalog to page 9Passive heat recovery Active heat recovery Sanitary hot water production Comfort cooling Comfort heating Product description The Compact P GEO solution has the same advantages and functions as Compact P, but additionally has an integrated 3 or 6 kW geothermal heat pump (JVP 3 & GEO 6). The geothermal heat pump is connected to the home’s low temperature central heating system and is a new type that are specially adapted for modern, low-energy houses with a relatively limited heating requirement. Due the variable compressor, the pumps’ capacity ranges from 1.5-3 kW and 2-6 kW, respectively....
Open the catalog to page 10Technical specifications Compressor variable speed Installation site, room temperature Supply voltage and connection 230V L+N+PE, 50 Hz Fuse size Start current, Imax, Start Standby electricity consumption Supplementary electrical heating Rated output, brine pump (max/min). A pump Rated current, brine pump (max/min). A pump Refrigerant filling Pressostat low pressure (on/off) Pressostat high pressure (on/off) Ethylene glycol/water Ethylene glycol/water Antifreeze Antifreeze, brine Design pressure brine/central heating side Expansion vessel brine/central heating side Booster expansion vessels...
Open the catalog to page 11All Nilan A/S catalogs and technical brochures
-
VP 18 M2
16 Pages
-
EM-BOX
4 Pages
-
COMPACT P - CTS602 HMI
32 Pages
-
COMFORT CT300/POLAR
20 Pages
-
COMPACT P - SERIES
44 Pages
-
COMBI S 302 POLAR TOP BY NILAN
16 Pages
-
Indoor Climate
36 Pages
-
Heating Elements
8 Pages
-
VPM 120-560 brochure
6 Pages
-
VPM 600 3200 brochure
24 Pages
-
Nilan Calculator brochure
8 Pages
-
Em-box by NILAN
4 Pages
-
Comfort 600
8 Pages
-
Comfort 450
8 Pages
-
Comfort 300 top
8 Pages
-
Comfort 300
8 Pages
-
Comfort 250 top
6 Pages
-
The future is decentralised
16 Pages
-
CTS 6000
4 Pages
-
Comfort CT300
8 Pages