PRODUCT DATA COMFORT CT300/POLAR BY NILAN Ventilation & passive heat recovery Passive heat recovery

Open the catalog to page 1
COMFORT CT300/POLAR - 2

COMFORT CT300/POLAR Product description Based on the many years’ experience from the Comfort series, Nilan has developed a future-proof system, Comfort CT300, that meets the 2020 requirements of ventilation systems, and is also passive-house certified. The unit is constructed to ensure low energy consumption by optimising the air flows in the system and thereby reducing the internal pressure loss, as well as using quality components with low energy consumption. We have thereby developed an energy-efficient ventilation system with heat recovery for homes and smaller commercial buildings with...

Open the catalog to page 2
COMFORT CT300/POLAR - 3

Can be connected to an external water or electrical pre-heating element Time controlled alarm for filter change. Easy filter access - the top front panel manually unscrews easily. There is plenty of space to replace filters and vacuum the filter space. Visual alarm for filter change. 100 % automatic bypass function that carries the air past the counterflow heat exchanger when heat recovery is not required. Aluzinc steel plate, white powder coating (RAL9016) Efficient counterflow heat exchanger providing high temperature efficiencey and low pressure loss, resulting in good heat recovery and...

Open the catalog to page 3
COMFORT CT300/POLAR - 4

TECHNICAL DATA Technical specifications Dimensions (W x D x H) Supply voltage Tightness class Plate type casing Heat exchanger type Aluzinc steel plate, white powder coating RAL9016 Polyethylenterephthalat counterflow heat exchanger Standby power Filter class Ambient temperature Duct connections Heat loss Condensate drain Heat loss classification Leakage classification *1 Testet according to EN13141-7 *1 Testet according to EN1886 AEC - annual electricity consumption Two-way ventilation unit for residential Variable speed drive Type of heat recovery system Recuperative (counterflow heat...

Open the catalog to page 4
COMFORT CT300/POLAR - 5

Dimensional drawing All dimensions are in mm. 1: Fresh air 2: Supply air 3: Extract air 4: Discharge air 5: Condensate drain

Open the catalog to page 5
COMFORT CT300/POLAR - 6

PLANNING DATA Nilan units are tested in accordance with the valid standards of accredited independent test institutes. Capacity Capacity of standard unit as a function of qv and Pt, ext. SEL values according to EN 13141-7 are for standard units with ISO Coarse >90% (G4) filters and without heating element. SEL values comprise the unit´s total power comsumption incl. control. Conversion factor: Attention! The SEL values are measured and stated as a total value for both fans. Pt ext [Pa] 400 350 300 250 Temperature efficiency Temperature efficiency for units with counterflow heat exchanger...

Open the catalog to page 6
COMFORT CT300/POLAR - 7

Sound data Sound output level (LWA) Octave band Hz Sound output level LWA drops with falling air volume and falling back pressure. Sound data for qV = 171 m3/h and Pt, ext = 100 Pa according to EN 9614-2 for surfaces and EN 5136 for ducts. Sound output level LpA at a given distance will depend on acoustic conditions in the place of installation.

Open the catalog to page 7
COMFORT CT300/POLAR - 8

OPERATION Intelligent humidity control Nilan’s humidity control automatically adapts to the needs of inhabitants or the building itself. Immediately change in % of RH The intelligent CTS400 / CTS602 control unit does not require a set air humidity level (RH) to manage the air exchange. Using the integrated humidity sensor, the control unit calculates the average humidity over the past 24 hours and regulates the air flow accordingly. Consequently the unit’s efficiency is based on actual instead of theoretical air humidity levels. Forced ventilation Reduced ventilation Normal ventilation...

Open the catalog to page 8
COMFORT CT300/POLAR - 9

Capacity - Heating element (accessory) Electrical heating element The electrical heating element is fitted in the supply air duct at a distance of min. 2 x duct diameter from the system´s fresh air connection pipe (normally min 320 mm.) and connected to the CTS400 / CTS602 control panel and 230 V supply. The electrical heating element can supply up to 1,2 kW of heat. Water heating element for duct fitting The water heating element is designed to be built into the duct and must be connected to the primary heating supply and the CTS400 / CTS602 control. The water heating element includes...

Open the catalog to page 9
COMFORT CT300/POLAR - 10

CTS400 is a simple and intuitive control panel with a complex control system that contains many useful functions. On the control panel you can set the fan speed level, turn the unit on and off and see potential alarms. When installed in rental properties, hotels etc., you can lock the panel so tenants cannot turn off the unit and/or alter the fan speed level. The many functions of the control system enable you to connect, for instance, afterheating elements and a CO2 or VOC sensor. The control system includes, as standard, user selection programs, an intelligent humidity control system and...

Open the catalog to page 10
COMFORT CT300/POLAR - 11

PC-Tool Nilan provides a PC tool for creating settings and for balancing the unit. This gets installed in the installer’s computer. Via a USB connection on the outside of the unit it is then connected to the circuit board for the unit. The selected settings can be saved to the installer’s computer and can be copied to another unit where the same settings are required. If necessary, PC Tool also allows the installer to update the software in the unit. The user has no access to alter the settings via PC Tool. Nilan User APP By purchasing a Nilan gateway, the user can gain access to the unit...

Open the catalog to page 11
COMFORT CT300/POLAR - 12

AUTOMATION CTS602 CTS602 Control The CTS602 HMI touch panel is featuring a wide range of functions, e.g., menu-controlled operation, weekly programme settings, filter monitor with timer, fan speed adjustment, summer bypass (free cooling), supply-heating element control, error messages etc. The CTS602 comes with factory settings, including a default setting which can be customised to operational requirements to achieve optimum operation and utilisation of the system. There is an option for selecting between 2 front page images for the main screen. Operating instructions for the CTS 602 can...

Open the catalog to page 12
COMFORT CT300/POLAR - 13

Functions overview Description of errors indicated with alarms. Alarm log displaying the latest 16 alarms. Joint alarm The CTS602 control system has an output signal that is activated in the case of an alarm. It can be connected to, for example, external automation. Filter monitor Filter alarm with timer that can be set to 30/90/180/360 days. Data display An overview of the current operation with regards to temperatures, fan speed level etc. Week program The CTS602 control system has 3 week programs that can be set individually (the default setting is “off”). Humidity control system Enables...

Open the catalog to page 13

All Nilan A/S catalogs and technical brochures

  1. VP 18 M2

    16 Pages

  2. EM-BOX

    4 Pages

  3. Indoor Climate

    36 Pages

  4. Compact p

    16 Pages

  5. Comfort 600

    8 Pages

  6. Comfort 450

    8 Pages

  7. Comfort 300

    8 Pages

  8. CTS 6000

    4 Pages