GROUND SOURCE HEAT PUMP NIBE™ F1255 PC Intelligent heat pump fitted with an inverter- controlled compressor Features of NIBE™ F1255 PC Integrated passive cooling Extraordinary high efficiency (SCOP). Optimal annual heating factor thanks to the inverter controlled compressor. Available in 1,5 - 6 kW Speed controlled circulation pumps that supply the heat pump with optimized fluid flow. M inimal operating costs, no expensive peaks when it is cold outside. The compressor adapts as necessary. Integrated hot water heater with environmentally friendly insulation for minimal heat loss. H igh temperature range – Flow line temperature up to 65°C (70°C) – Return line temperature up to 58°C Scheduling (indoor climate, hot water, ventilation). Control of up to four heating systems. Accessories available for e.g. pool heating. Compatible with NIBE Uplink NIBE F1255 PC NIBE F1255 PC is an intelligent heat pump fitted with an invertercontrolled compressor and speed-controlled circulation pumps. Suitable for use in residential and commercial buildings. The heat pump adjusts itself automatically to the power demand of the house. This results in optimal savings as the heat pump always runs at the correct performance all year round without the addition of extra electrical peaks. The integrated coil water heater is available in enamel and stainless steel. It is prepared for connection to several different products and accessories, for example, hot water heater, ventilation recovery, pool and heating systems with different temperatures. A +++ Energy efficiency class package label for NIBE
Open the catalog to page 11) At Nominal power *The reported efficiency of the package also takes the controller into account. **According to EN 12102 at 0/35 °C *** According to EN 11203 at 0/35 °C and 1 m distance System description NIBE F1255 consists of a heat pump, water heater, electric heater, circulation pumps and control computer with display. NIBE F1255 is connected to the brine and heating medium circuits. The heat from the heat source (rock, soil, lake) is taken up via a closed brine system in which a mixture of water and antifreeze circulates. Groundwater can also be used as a heat source, but this requires...
Open the catalog to page 248 Pages
16 Pages
44 Pages
76 Pages
72 Pages
2 Pages
36 Pages
4 Pages
32 Pages
4 Pages
32 Pages
2 Pages
32 Pages
8 Pages
24 Pages
2 Pages
22 Pages
22 Pages
28 Pages
2 Pages
36 Pages
16 Pages
16 Pages
16 Pages
64 Pages
20 Pages
20 Pages
48 Pages
32 Pages