The NIBE™ F1255 is a ground source heat pump designed for heating small houses and smaller multi-occupancy houses. It uses rock, ground, or lake as a heat source and automatically adjusts its output to optimize energy savings throughout the year.
Specifications:
  • Includes a 180-liter water heater and a 7-step 7 kW immersion heater.
  • Features an inverter-controlled compressor for optimal heating efficiency.
  • Operates with a high temperature range, supply temperature up to 70°C, and return temperature up to 58°C.
  • Equipped with a user-friendly display unit with a large color screen.
Installation Methods:
  • Rock: Utilizes solar energy stored in rock via a borehole collector.
  • Surface Soil: Uses a buried ground collector to harness solar energy stored in the ground.
  • Lake: Employs a lake collector anchored on the lake bed to capture solar energy stored in water.
Operation Principle:
The F1255 integrates a heat pump, water heater, electric heater, circulation pumps, and a control system. It uses a closed brine system with a water-antifreeze mixture to transfer heat from the source to the heating medium circuit.
Installation Guidelines:
  • Transport and store the unit vertically in a dry place.
  • Position on a firm base, preferably concrete, and ensure sound insulation if near noise-sensitive areas.
  • Allow 800 mm space in front for service access.
Components and Connections:
  • Includes sensors, circulation pumps, and various valves for efficient operation.
  • Pipe connections for heating medium supply/return, cold/hot water, and brine in/out.
Display and Controls:
  • Features a menu system with options for indoor climate, hot water, information, and heat pump settings.
  • Includes a start guide for initial setup and configuration.
Additional Features:
  • Prepared for pool heating, control of multiple heating systems, and active/passive cooling with optional accessories.
  • Remote control and monitoring via NIBE Uplink™ or SMS.
Installation and Connection Procedures:
The document outlines the installation procedures for the NIBE F1255 heat pump system, including instructions for connecting the brine and heating medium pipes. Safety devices, shut-off valves, and particle filters must be installed close to the heat pump.
Ventilation and Pool Heating:
The system can be supplemented with the NIBE FLM module for ventilation recovery and the POOL 40 accessory for pool heating. Pipes and cold surfaces must be insulated to prevent condensation.
Climate System Control:
The F1255 can control multiple climate systems with accessories ECS 40/ECS 41, allowing for different temperature settings. Free cooling can be achieved with fan convectors.
Inspection and Guidelines:
Heating installations must be inspected by qualified personnel before commissioning. Guidelines for collector hose length and installation depth are provided.
Control and Operation:
The heat pump operates on a "floating condensing" principle, adjusting heat production based on outdoor temperatures. It can also function as an additional heater and has a brine pump for continuous operation.
Technical Specifications:
The document provides detailed technical specifications, including output data, electrical data, and refrigerant circuit information. The heat pump uses R407C refrigerant.
Accessories and Additional Features:
  • MODBUS 40 for control and monitoring via MODBUS-RTU communication.
  • Exhaust Air Module FLM for mechanical exhaust air recovery.
  • Extra Shunt Group ECS 40/41 for installations with multiple climate systems.
  • Pool Heating POOL 40 for enabling pool heating.
  • Passive Cooling PCS 44 for cooling in addition to heating.
  • Communication Module SMS 40 for operation and monitoring via GSM module.
  • Accessory Card AXC 40 for step-controlled or shunt-controlled additions.
  • Room Unit RMU 40 for control and monitoring from a different location.
  • Filling Valve Kit Brine G32 for filling brine in collector hoses.
  • SOLAR 40/42 for connecting to solar heating systems.
Standards and Certifications:
NIBE is ISO-certified under SS-EN ISO 9001:2000 and SS-EN ISO 14001:2004.
Contact Information:
NIBE Energy Systems AB, Box 14, 285 21 Markaryd, SWEDEN. Tel. +46 433 - 73 000, www.nibe.eu
Disclaimer:
The brochure contains product illustrations, facts, and specifications based on current information at the time of publication. NIBE reserves the right for any factual or printing errors.
See more

Catalog excerpts

F1255-1

NIBE™ F1255 GROUND SOURCE HEAT PUMP HEAT PUMP WITH ROCK, GROUND OR LAKE AS HEAT SOURCE. • Optimal annual heating factor thanks to the inverter controlled compressor. Minimal operating costs, the compressor increases/ decreases speed according to the prevailing heating demand. Software controlled circulation pumps that supply the heat pump and the heating system with suitable flow. It also gives you the opportunity to control comfort in your home no matter where you are by using NIBE UplinkTM. Display unit with large and easy-to-read colour screen (TFT). – User friendly control system. – cons and text for clear information about status, I temperatures and settings in the heat pump. – indoor sensor included. High temperature range. Integrated clock with real time function for scheduling changing of hot water and indoor house temperature. Prepared for (with accessory): – ool heating (POOL40) for both pool and spa. P – ontrol of up to four heating systems (ECS40/ECS41). C – tatus and settings via NIBE UplinkTM or via SMS S (SMS40). – Active / passive cooling with PCM 42 or HPAC 40. Easy to remove the cooling module. NIBE F1255 NIBE™ F1255 is a heat pump for heating small houses and smaller multi-occupancy houses. The heat pump automatically adjusts itself to the output requirement of the house during the year. When more heat and hot water is required, the output increases, when not so much is needed, it drops to a lower speed. This results in optimal savings as the heat pump always runs at the correct performance all year round. Both the low energy circulation pumps and the flexible hoses are integrated, and the brine circuit can be connected on either side. Particle filter supplied. The heat pump can be connected to an optional low temperature distribution system. e.g. radiators, convectors or under floor heating. F1255 is equipped with a 180 litre water heater, which is optimally insulated for minimal heat loss. An integrated 7 step 7 kW immersion heater connects automatically as necessary. (can be connected to a 4-step 9 kW immersion heater). F1255 is constructed on a robust frame with durable panels and effective soundproofing for the best possible comfort. All panels are easy to remove for easy access when installing and for any servicing.

 Open the catalog to page 1
F1255-2

INSTALLATION METHOD Rock The heat pump collects a proportion of the rock’s stored solar energy via a collector in a bore hole in the rock. Brine to heat pump Brine from heat pump Sleeve pipe Ground water level Active borehole (water column in rock) Surface soil The heat pump obtains a proportion of the ground's stored solar energy via the buried ground collector. The heat pump obtains a proportion of the water’s stored solar energy via the lake collector that is anchored on the lake bed.

 Open the catalog to page 2
F1255-3

HOW DOES F1155 WORK? Principle of operation F1255 consists of heat pump, water heater, electric heater, low energy circulation pumps and control system. F1255 is connected to the brine and heating medium circuits. The heat from the heat source (rock, soil, lake) is taken up via a closed brine system in which a mixture of water and antifreeze circulates. In some cases, the ground water can also be used as heat source. An intermediate heat exchanger should be used to protect the heat pump in such cases. In the heat pump evaporator, the brine (water mixed with anti-freeze, e.g. glycol or ethanol)...

 Open the catalog to page 3
F1255-4

GOOD TO KNOW ABOUT NIBE™ F1255 Transport and storage F1255 should be transported and stored vertically in a dry place. Position the heat pump on a firm base, preferably on a concrete floor or foundation. Use the heat pump’s adjustable feet to obtain a stable set-up. Install with its back to an outside wall, ideally in a room where noise does not matter, in order to eliminate noise problems. If this is not possible, avoid placing it against a wall behind a bedroom or other room where noise may be a problem. Wherever the unit is located, walls to sound sensitive rooms should be fitted with sound...

 Open the catalog to page 4
F1255-5

GOOD TO KNOW ABOUT NIBE™ F1255 *This dimension applies at 90° angle on the brine pipes (side connection). The dimension can vary approx. ±100 mm in height as the brine pipes partially consist of flexible pipes.

 Open the catalog to page 5
F1255-6

GOOD TO KNOW ABOUT NIBE™ F1255 Equipment

 Open the catalog to page 6
F1255-7

GOOD TO KNOW ABOUT NIBE™ F1255 Pipe connections Electrical components Connection, heating medium supply Immersion heater card Connection, heating medium return Base card Connection, cold water Input circuit board Display unit AA4-XJ4 Service socket (no function) AA23 Communication board HVAC components Circulation pump Immersion heater Brine pump Miniature circuit-breaker Drainage, climate system Temperature limiter/Emergency mode thermostat Draining, brine side QM22 Venting valve, coil QM31 Shut-off valve, heating medium supply W130 Network cable for NIBE Uplink™ QM32 Shut off valve, heating...

 Open the catalog to page 7
F1255-8

Tillgängligt tryck, kPa Eleffekt, W GOOD TO KNOW ABOUT NIBE™ F125590 80 Pump capacity diagram Heating medium side Automatic operation To set the correct flow in the climate system the correct speed must be set for the heating medium pump. This heat pump has a heating medium pump that can automatically controlled. This automatic control occurs when the compressor is running and automatically sets the speed of the heating medium pump, for the present operating mode, to obtain the optimal temperature difference between the supply and return lines. Manual operation Available pressure Tillgängligt...

 Open the catalog to page 8
F1255-9

Tillgängligt tryck, kPa Eleffekt, W GOOD TO KNOW ABOUT NIBE™ F1255 90 80 Pump capacity diagram Brine side Automatic operation To set the correct flow in the brine system the correct speed must be set for the brine pump. This heat pump has a brine pump that can automatically controlled. This automatic control occurs when the compressor is running and automatically sets the speed of the brine pump for the optimal temperature difference between the supply and return lines. Manual operation Available pressure Tillgängligt tryck Electrical output Eleffekt Available pressure, kPa Electrical output,...

 Open the catalog to page 9

All NIBE Energy Systems catalogs and technical brochures

  1. SMO 40

    48  Pages

  2. S1156/S1256

    16  Pages

  3. F470

    76  Pages

  4. F1345

    72  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.