video corpo cad

PermaBase Cement Board
12Pages

{{requestButtons}}

Catalog excerpts

PermaBase Cement Board - 1

PermaBase > 09 28 00/NGC BRAND Cement Board > Construction Guide size="-1">

Open the catalog to page 1
PermaBase Cement Board - 2

PermaBase > ή BRAND Cement Boardis a rigid substrate made of Portland cement, aggregate and glass mesh that provides an exceptionally hard, durable surface that is able to with- stand prolonged exposure to moisture.PermaBase offers a competitiveadvantage over similar products on the market with its patented EdgeTech > technology. The tapered,double-wrapped edge design allows for closer nail or screw application to the edge. > Double-wrapped edge withEdgeTech technology allows for closer fastener application of nails or screws at the edge without crumbling or spinout. > IRC and IBC 2006...

Open the catalog to page 2
PermaBase Cement Board - 3

Size: Thickness, Width & Length# of Pcs. Per Unit > PermaBase Cement Board > OtherFiberCementCement Physical Feature BenefitsPermaBaseBoardsBoards > Lowest Weight Glass Mesh Cement Board > Double-Wrapped Edge Fastens Near Edge With No Breakout Highest Damage Resistancy From Handling Cleanest To Score And Snap Lowest Water Absorption > Meets 40 psf Rating Wind Load Test Results (Stud spacing 16" o.c.) Cuts With Utility Knife vs. Power Tools Standard Fasteners Countersink Into Board Can Be Used In Both Residential and Commercial Steam Rooms And Saunas > Fewer Expansion Joints Needed >...

Open the catalog to page 3
PermaBase Cement Board - 4

TUB & SHOWER SURROUND An ideal underlayment for interior applications such as: Shower and tub enclosures Garden/whirlpool tubs Countertops Backsplashes Steamrooms and saunas Swimming pool and whirlpool decks and enclosures Floor underlayment Entryways ֖ Kitchens Bathrooms ֖ Foyers Laundry rooms > 2"x 4" Wood Studs or 20 ga. 3-5/8" Metal Studs 16" o.c. General: All framing should complywith local building code require- ments and be designed to provide support with a maximum allowable deflection of L/360 under all intend- ed loads. Framing members should be spaced a maximum of 16" o.c. > ֮...

Open the catalog to page 4
PermaBase Cement Board - 5

Tile Latex-PortlandCement Mortar Tile Latex-PortlandCement MortarPermaBase Cement Board Fiberglass Mesh Tape(Alkali Resistant) Cabinet PlywoodPermaBase Cement BoardLatex-PortlandCement MortarFiberglass Mesh Tape(Alkali Resistant) I-Joists Latex-PortlandCement Mortar Plywood >

Open the catalog to page 5
PermaBase Cement Board - 6

Underlayment: Using a 1/4"square-notched trowel, apply a setting bed of latex-Portland cement mortar to the subfloor. Immediately laminate PermaBase to subfloor, leaving a 1/8" space between boards at all joints and corners. Leave a 1/4" gap along walls. Stagger all joints so they do not line up with underlying substrate joints. Fasten PermaBase every 8" o.c. throughout board field and around all edges while setting bed mortar is still workable. Around the perimeter of each board, locate fasteners 2" from the corners and not less than 3/8" from the edges. Fill all joints solid with bonding...

Open the catalog to page 6
PermaBase Cement Board - 7

Cement Board Stucco is a water-managed exterior wall system designed to provide increased high- impact and weather resistance and improved dimensional stability where exterior insulation value is not required. For the purposes of meeting structural racking or fire code requirements, it is applied over the following approved sheathings: Exposure 1 or exterior plywood (grade C-D or better); Exposure 1 OSB; glass mat gypsum substrate meeting ASTM C 1177; or water resistant core gypsum (ASTM C 1396).It combines the strength and dura-bility of PermaBase Cement Board with the performance and...

Open the catalog to page 7
PermaBase Cement Board - 8

Fire RatingUL Design No.Description 1 hr.V452 1 hr.V438 1/2" PermaBase applied vertically or horizontally over 5/8" Fire-Shield Gypsum Board applied vertically to each side of 3-5/8" steel studs 24" o.c. PermaBase secured to studs with cement board screws of adequate length to penetrate studs 3/8" spaced 8" o.c. 1 hr.U420 1/2" PermaBase applied vertically or horizontally over 5/8" Fire-Shield Gypsum Boardapplied vertically to each side double row of 1-5/8" steel studs 24" o.c. spaced 6" apart. PermaBase secured to studs with cement board screws of adequate length to penetrate studs 3/8"...

Open the catalog to page 8
PermaBase Cement Board - 9

Property Test Method1/2" PermaBase > Water Absorption % ASTM C 473<8 by Weight/24 Hours Flexural Strength (psi)ASTM C 947750 Fastener Holding ASTM D 103790 > (Wet and Dry, lbs.)(0.400" head diameter) Weight (psf)ASTM C 4733 Freeze/Thaw (cycles)ASTM C 666100 per ANSI A118.9Procedure BFlame Spread/ASTM E 840/0 > ֮ Smoke DevelopedCompressive Strength (psi)ASTM D 23942250 (Indentation)Wind Load ASTM E 33040 (psf, studs 16" o.c.) Thermal RӔ/k ValueProperty of Material0.2/2.7 Bending Radius (ft.)Property of Material5 Standard Method forASTM C 627Lightevaluating ceramicCommercial floor...

Open the catalog to page 9
PermaBase Cement Board - 10

PermaBase Flex > ή BRAND CementBoard is a polymer-modified cement board reinforced with an alkali-resistant fiber mesh ideal for use around ceilings, beams, columns, arches and archways, walls and anywhere an evenly curved surface is required. > Radius wall construction Exterior and interior columns Barrel ceilings Radius shower walls Radius tub step-ups Radius archways Radius stair construction > PermaBase Flex makes curved designs easy to achieve. On this indoor pool ceilingapplication, PermaBase Flex is used with a hard coat plaster finish. Saunas and steamrooms > Do not use drywall...

Open the catalog to page 10
PermaBase Cement Board - 11

INTERIOR APPLICATIONS Wall Framing: Studs should bespaced a maximum of 8" o.c. Edges/ends of PermaBase Flex parallel to framing should be continuously supported. Provide additional blocking when neces- sary to permit proper PermaBase Flex attachment. Do not install PermaBase Flex directly over protrusions from stud plane such as heavy brackets or fastener heads.Studs above a shower floor shouldbe either notched or furred to accommodate the thickness of the waterproof membrane or pan. The surround opening for a tub or precast shower receptor should not be more than 1/4" longer than unit to...