INSTALLER: PLEASE FAMILIARIZE YOURSELF WITH VENTING/DRAINING SECTIONS OF THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. LEAVE THIS MANUAL WITH THE APPLIANCE FOR FUTURE REFERENCE. CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE. INSTALLATION AND OPERATING INSTRUCTIONS CERTIFIED TO ANSI Z21.47-2016 / CSA 2.3-2016 9700 - B SERIES TWO STAGE HIGH EFFICIENCY (CONDENSING) FORCED AIR GAS FURNACE SAFETY INFORMATION ELECTRICAL SHOCK, FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury, death or property damage. Improper servicing could result in dangerous operation, serious injury, death or property damage. - Installation and service must be performed by a qualified installer, service agency or the gas supplier. - Before servicing, disconnect all electrical power to furnace. - When servicing controls, label all wires prior to disconnecting. Reconnect wires correctly. - Verify proper operation after servicing. Patent Pending - Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. - WHAT TO DO IF YOU SMELL GAS: • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Leave the building immediately. • Immediately call your gas supplier from a neighbour’s phone. Follow the gas supplier’s instructions. • If you cannot reach your gas supplier, call the fire department. MANUFACTURER RESERVES THE RIGHT TO DISCONTINUE, OR CHANGE AT ANY TIME, SPECIFICATIONS OR DESIGNS WITHOUT NOTICE AND WITHOUT INCURRING OBLIGATIONS. Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada / 103 Miller Drive, Crittenden, Kentucky, USA, 41030 Phone (705)721-1212 • Fax (705)722-6031 • www.napoleonheatingandcooling.com • hvac@napoleonproducts.com H1.27C $10.00

Open the catalog to page 1
9700 - B SERIES - 2

TABLE OF CONTENTS 1.0 INTRODUCTION 3 2.0 SAFETY SYMBOLS AND WARNINGS 4 4.3 INSTALLATION IN UPFLOW POSITION 11 7.0 VENTING AND COMBUSTION PIPING 15 7.1 ACCEPTABLE MATERIALS IN CANADA 15 7.2 ACCEPTABLE MATERIALS IN UNITED STATES 15 7.3 VENT DRAIN OPTION 16 8.0 NON-DIRECT VENT FURNACE INSTALLATIONS USING INDOOR COMBUSTION AIR (ONE PIPE SYSTEM) 17 8.1.1 CASE 1: FURNACE LOCATED IN A UNCONFINED SPACE 18 8.1.2 CASE 2: FURNACE LOCATED IN A CONFINED SPACE 18 8.1.3 CASE 3: FURNACE LOCATED IN A CONFINED SPACE, OUTDOOR AIR FROM ATTIC OR CRAWL SPACE 19 8.1.4 CASE 4: FURNACE LOCATED IN A CONFINED SPACE,...

Open the catalog to page 2
9700 - B SERIES - 3

16.0 OPTIONAL ACCESSORIES (FIELD SUPPLIED/INSTALLED) 44 16.3 EMERGENCY HEAT MODE 44 17.0 INITIAL START-UP PROCEDURES 45 17.2 TO SHUT DOWN THE FURNACE 45 17.4 PROGRAMMABLE THERMOSTAT (OPTION) 46 18.1 TEMPERATURE RISE CHECK 47 18.3 ADJUSTING BLOWER SPEEDS ON ECM EON BLOWER MOTORS 48 18.5 SETTING BLOWER “ON” AND “OFF” TIMINGS - ECM EON MODELS ONLY 49 19.4 DIAGNOSTIC CODES FOR STATUS LED 52 19.5 FAULT CODE HISTORY 52 19.6 INTERNAL LIGHTING SYSTEM 52 20.0 WIRE DIAGRAM FOR TWO STAGE FURNACE WITH ECM EON 54 22.0 REPLACEMENT PARTS LIST 57 NOTE: Changes, other than editorial, are denoted by a...

Open the catalog to page 3
9700 - B SERIES - 5

THESE INSTRUCTIONS ARE INTENDED AS AN AID TO QUALIFIED SERVICE PERSONNEL FOR PROPER INSTALLATION, ADJUSTMENT AND OPERATION OF THIS FURNACE. READ THESE INSTRUCTIONS THOROUGHLY BEFORE ATTEMPTING INSTALLATION OR OPERATION. FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RESULT IN IMPROPER INSTALLATION, ADJUSTMENT, SERVICE OR MAINTENANCE, POSSIBLY RESULTING IN FIRE, ELECTRICAL SHOCK, CARBON MONOXIDE POISONING, EXPLOSION, PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. H3.4 CARBON-MONOXIDE POISONING HAZARD FAILURE TO FOLLOW INSTRUCTIONS COULD RESULT IN SEVERE PERSONAL INJURY OR DEATH DUE TO CARBON-MONOXIDE...

Open the catalog to page 5
9700 - B SERIES - 6

CODES 1. This furnace must be installed: a. In accordance with all local codes, by-laws and regulations by those authorities having jurisdiction. b. In Canada, this furnace must be installed in accordance with the current CAN/CGA -B149.1 and .2 Natural Gas and Propane, and the National Electric Code (NEC) NFPA 70. c. In the United States, this furnace must be installed in accordance with the current ANSI Z223.1 (NFPA 54) National Fuel Gas Code. 2. Electrical connections must be made in accordance with: a. Any applicable local codes, by-laws and regulations. b. Canada: current edition of...

Open the catalog to page 6
9700 - B SERIES - 7

WHEN THIS FURNACE IS INSTALLED IN A STORAGE GARAGE, IT MUST BE INSTALLED SO THE BURNERS AND IGNITION SOURCE ARE LOCATED NO LESS THAN 18” (457 mm) ABOVE THE FLOOR TO PREVENT THE RISK OF IGNITING FLAMMABLE VAPORS WHICH MAY BE PRESENT IN THE GARAGE. THE FURNACE MUST BE LOCATED OR PROTECTED TO AVOID PHYSICAL DAMAGE BY VEHICLES. FAILURE TO HEED THESE WARNINGS CAN CAUSE A FIRE OR EXPLOSION, RESULTING IN PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. H3.6A FIGURE 1 - FURNACE DIMENSIONS 0.625” (15.875 MM) STD. GAS SUPPLY ALTERNATE VENT OUTLET ALTERNATE AIR IN CONDENSATE DRAIN TRAP WITH 1/2” CPVC...

Open the catalog to page 7
9700 - B SERIES - 8

1. Combustion Air Intake Fitting 13. 2. Flame Roll-Out Switch (2) 14. 3. Flame Sensor - located underneath 15. 5. Air High Temperature Limit - supply air 17. 6. Vent and Drain (Assembly) Coupling 18. 7. Drain for Recovery Coil (3) 9. Two Stage Integrated Furnace Control (IFC) 20. 12. Hot Surface Igniter (HSI)(located underneath) Two Speed Exhauster Pressure Switch Assembly Front Manifold Cover Pressure Tap (3) PFC “Choke Coil” (used on % and 1 Hp units only) Door Switch and Junction Box Blower Motor (not shown, located on right side of blower) Circulating Air Blower UV Light Ballast UV...

Open the catalog to page 8
9700 - B SERIES - 9

3.0 FURNACE SIZING The maximum hourly heat loss for each heated space shall be calculated in accordance with the procedures described in the manuals of the Heating, Refrigeration and Air Conditioning Institute of Canada (HRAI), or by any other method which is suitable for local conditions, provided the results obtained are in substantial agreement with, and not less than those obtained using the procedure described in their manuals. In the United States, “Manual J - Load Calculation," published by the Air Conditioning Contractors of America, describes a suitable procedure for calculating...

Open the catalog to page 9