9700 - B SERIES Technical Specifications
4Pages

{{requestButtons}}

Catalog excerpts

9700 - B SERIES Technical Specifications - 1

ENGINEER APPROVAL Technical Specifications 9700 - B SERIES (NUV) Napoleon Two Stage, Variable Speed, Condensing Gas Furnace Up to 97.1% AFUE Certified through AHRI Input 40,000 - 120,000 Btuh The Ultimate 9700 Series High Efficiency Gas Furnace is certified for upflow installation only, and requires zero clearance. Certified by CSA for application in Canada and the United States. Furnace is less than 33” (838 mm) tall! Variable Speed ECM EON Blower Motor 409 SS Wrinkle Bent Primary Heat Exchanger Tubes 29-4C Stainless Steel Heat Recovery Coil Aluminized Multi-Port In-Shot Burners Self Diagnostic Integrated Furnace Control Durable powder coated, acoustically, and thermally Insulated Cabinet Zero Clearance, up flow position only Direct and Single Vent installation approved Concentric Venting Approved 100% Units factory fired Internal Condensate Trap Clear Front Manifold Cover Easy Blower removal Sealed Vestibule and Blower Compartments for quiet operation Natural Gas and LP (propane) only Low fire is 60% of high fire rate Built in LED lights in upper and lower compartments Insulated Front Door Factory installed Ultra Violet Light Air Purifier Napoleon Elite Communicating Thermostat ready WARRANTY PRESIDENT’S LIMITED WARRANTY (Registered) To the original registered owner and his or her spouse (“owner”), the HEAT EXCHANGER* is warranted for the owner’s LIFETIME or so long as the owner owns the home in which the unit was originally installed, and all remaining parts as warranted for a period of 10 YEARS, except as provided below. These warranties apply only if: • The unit is installed in an owner-occupied, primary single family residence, and • The unit is properly registered with Napoleon online within 60 days after the original installation. To register, go to www.napoleonheatingandcooling.com. Some states and provinces www.napoleonheatingandcooling.com. p g g do not allow limitations on how long an implied limited warranty lasts or do not allow the exclusion or limition of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This limited warranty gives you specific legal rights, and you may also have other rights which vary by jurisdiction. With respect to the Heat Exchanger, if the heat exchanger fails within: ○ the first 10 years for 9500 / 9600E / 9600 Series first ○ the first 15 years for 9700 Series Napoleon will, at its discretion, provide a new equivalent gas furnace. After the 10 years (15 years - 9700 Series), Napoleon may choose to credit its prorated wholesale value towards the purchase of a new Napoleon furnace. Design Level B = Builders S = Standard P = Premium U = Ultimate Airflow Tonnage 2 = 2 Tons 3 = 3 Tons 4 = 4 Tons 5 = 5 Tons M = Multi Speed X = X13 DC Drive V = ECM EON S = Single Stage T = Two Stage Input Capacity 040 = 40,000 Btuh 060 = 60,000 Btuh 080 = 80,000 Btuh 100 = 100,000 Btuh 120 = 120,000 Btuh H12.12.11A LIMITED WARRANTY (Not Registered) If not registered within 60 days, the HEAT EXCHANGER is warranted for a period of 20 YEARS (pro rated), and all remaining parts are warranted for a period of 5 YEARS, all other limitations apply. With respect to the heat exchanger, Napoleon at its discretion, after 5 years may choose to provide a credit towards a replacement Napoleon gas furnace. Annual Fuel Utilization Efficiency (AFUE) Gas- or Propane-fir

Open the catalog to page 1
9700 - B SERIES Technical Specifications - 2

HEATING CAPACITIES GAS FURNACE COMPONENTS LEGEND 1. Combustion Air Intake Fitting 2. Flame Roll-Out Switch (2) 3. Flame Sensor - located underneath 5. Supply Air High Temperature Limit 6. Vent and Drain (Assembly) Coupling 7. Drain for Recovery Coil (3) 9. Two Stage Integrated Furnace Control (IFC) 14. Pressure Switch Assembly 15. Front Manifold Cover Pressure Tap (3) 16. PFC “Choke Coil” (used on % and 1 Hp units only) 17. Door Switch and Junction Box

Open the catalog to page 2
9700 - B SERIES Technical Specifications - 3

TABLE A - FURNACE DIMENSIONS In Canada, this funace does not need to be converted for high altitude (2000-4500ft), when the fuel source is natural gas. It has been certified to operate at high altitude as manufactured. If the fuel source is liquid propane, refer to High Altitude Specifications table for appropriate derate above 2000ft based on a 4% reduction of input capacity for every 1000ft above sea level. In the United States, this furnace does not need to be converted for high altitude from (2000-5400ft), when the fuel source is natural gas. It has been certified to operate at high...

Open the catalog to page 3
9700 - B SERIES Technical Specifications - 4

Vent lengths that require more than 6-90° elbows, add listed equivalents for every elbow up to the maximum allowable vent length. In Canada: Furnace must be vented with S636 PVC or PPE In United States: • Schedule 40 PVC, ASTM D1785 or CSA B137.3 • PVC-DWV, ASTM D2665 or CSA B181.2 • Schedule 40 CPVC, ASTM F441 or CSA 137.6 • PVC PRIMER AND SOLVENT CEMENT: ASTM D2564 • PPE ULC S636 TABLE 4 - DIRECT AND NON-DIRECT VENT LENGTHS Maximum Allowable Length Of Exhaust Or Intake. Minimum Vent Length 15 ft. (4.6 m) or equivalent.

Open the catalog to page 4