Overview: This document serves as a detailed guide for the installation and application of NUDURA RetroFit Insulation Technology, highlighting its ease of installation, superior performance, and energy efficiency.
Specifications: NUDURA panels are available in 4’ x 8’ sheets with thickness options of 2 ⅝” and 3½”. Constructed from Expanded Polystyrene (EPS), these panels are lightweight and easy to cut. They include an embedded 2 ½” fastening strip at 16” centers and utilize a shiplap system to prevent thermal bridging.
Installation Procedures:
  • Wall Preparation: Ensure the foundation wall is free of excess concrete debris for flat panel placement. An air barrier may be necessary based on local codes.
  • Panel Installation: Begin at the foundation wall corner, adjusting shoulder edges for spacing. Secure panels with mechanical fasteners like concrete screws, spaced vertically every 2 feet.
  • Window Installation: Trim panels to fit around windows, leaving a gap for NUDURA’s Low Expansion Spray Foam to create a thermal barrier.
  • Electrical Installation: Use a hot knife or router to cut wiring channels, avoiding cuts through the wood fastening strip. Secure electrical boxes appropriately.
  • Drywall Installation: Attach ½” drywall to the wood fastening strip using 1¼” drywall screws, with strips placed 16” on center.
Performance and Benefits: NUDURA RetroFit Insulation Technology offers insulation ratings up to R-14, improving energy efficiency and comfort. It is environmentally friendly, free from VOCs, CFCs, or HCFCs, and resistant to moisture.
Recommendations: Always check local building codes for compliance. For corner bead installation, consult local supply chains or manufacturer guidelines.
Limitations: NUDURA disclaims liability for installation or workmanship issues, and the information is provided for informational purposes only.
See more

Catalog excerpts

RetroFit Brochure 2012-1

RetroFit NUDURA Insulation Technology RetroFit NUDURA Insulation Technology For more information and to download our Technical Data Sheet on NUDURA Insulation Technology visit Nudura.com Or visit our YouTube Channel for our RetroFit Installation Video. NUDURA® has no control over the installation or workmanship used in the assembly or the installation of the NUDURA® products, therefore, NUDURA® shall not be liable for any general, special, direct, indirect or consequential damages, including bodily harm that may be suffered by any person including, without limitation, the installer, contractor, architect, engineer, homeowner or customer due to the use, assembly or installation of NUDURA®. Information and suggestions contained in this brochure are offered for information purposes only and to the best of our knowledge can be considered reliable. All suggested applications must first be evaluated with regard to the specific circumstances, and in light thereof, may need to be adapted or modified if necessary to take account of local conditions and materials used. This brochure cannot in any case be considered an Undertaking or Guarantee whether concerning either the information data or suggestions included. Be sure to consult relevant building codes to ensure all applicable regulations are observed. ND1205E Easy Installation. Superior Performance.

 Open the catalog to page 1
RetroFit Brochure 2012-2

NUDURA Insulation Technology NUDURA RetroFit Insulation Technology is an easy–to-use insulation solution for finishing basements or insulating interior or exterior block walls. Installation is fast and effortless, compared to conventional multi-step finishing methods, as the NUDURA RetroFit Insulation Technology insulates and creates fastening points in one simple step. NUDURA Insulation Technology Watch our RetroFit Installation Video. Figure 8 Installation Around Windows For installation around windows, cut and remove the appropriate amount of panel needed, then fasten (Figure 8). When installing...

 Open the catalog to page 2
RetroFit Brochure 2012-3

NUDURA Insulation Technology INSTALLATION GUIDE Wall Preparation Before installation of the NUDURA Insulation Technology panels, remove any excess concrete debris that may have seeped between forming panels during concrete pour of the foundation. Simply chip off the excess concrete with a brick chisel or concrete chisel to ensure the panels sit flat on the foundation wall (Figure 1). Figure 1 Figure 2 Note: If necessary, an air barrier consisting of either TYVEC or TYPAR might be required to be placed between the wall and the insulation panel. Check with local building codes to determine if this...

 Open the catalog to page 3
RetroFit Brochure 2012-4

NUDURA Insulation Technology Easy Installation. 1. NUDURA Insulation Technology - Available in 4’ x 8’ (1.2 m x 2.4 m ) sheets that are 2 5/8 (67 mm) or 3 1/2” (89 mm) in thickness. 2. Wood Fastening Strip - Provided every 16” (400 mm) on center. 3. Electrical Wiring - Quick and easy to insert using a variety of tools. 4. Shiplap System - Panels fit easily together creating a solid thermal barrier. 5. Drywall - Easily fastened on NUDURA’s patented wood fastening strips. Easy Installation

 Open the catalog to page 4
RetroFit Brochure 2012-5

NUDURA Insulation Technology Easy Installation. 1. NUDURA Insulation Technology - Available in 4’ x 8’ (1.2 m x 2.4 m ) sheets that are 2 5/8 (67 mm) or 3 1/2” (89 mm) in thickness. 2. Wood Fastening Strip - Provided every 16” (400 mm) on center. 3. Electrical Wiring - Quick and easy to insert using a variety of tools. 4. Shiplap System - Panels fit easily together creating a solid thermal barrier. 5. Drywall - Easily fastened on NUDURA’s patented wood fastening strips. Easy Installation

 Open the catalog to page 5
RetroFit Brochure 2012-6

NUDURA Insulation Technology INSTALLATION GUIDE Wall Preparation Before installation of the NUDURA Insulation Technology panels, remove any excess concrete debris that may have seeped between forming panels during concrete pour of the foundation. Simply chip off the excess concrete with a brick chisel or concrete chisel to ensure the panels sit flat on the foundation wall (Figure 1). Figure 1 Figure 2 Note: If necessary, an air barrier consisting of either TYVEC or TYPAR might be required to be placed between the wall and the insulation panel. Check with local building codes to determine if this...

 Open the catalog to page 6
RetroFit Brochure 2012-7

NUDURA Insulation Technology NUDURA RetroFit Insulation Technology is an easy–to-use insulation solution for finishing basements or insulating interior or exterior block walls. Installation is fast and effortless, compared to conventional multi-step finishing methods, as the NUDURA RetroFit Insulation Technology insulates and creates fastening points in one simple step. NUDURA Insulation Technology Watch our RetroFit Installation Video. Figure 8 Installation Around Windows For installation around windows, cut and remove the appropriate amount of panel needed, then fasten (Figure 8). When installing...

 Open the catalog to page 7
RetroFit Brochure 2012-8

RetroFit NUDURA Insulation Technology RetroFit NUDURA Insulation Technology For more information and to download our Technical Data Sheet on NUDURA Insulation Technology visit Nudura.com Or visit our YouTube Channel for our RetroFit Installation Video. NUDURA® has no control over the installation or workmanship used in the assembly or the installation of the NUDURA® products, therefore, NUDURA® shall not be liable for any general, special, direct, indirect or consequential damages, including bodily harm that may be suffered by any person including, without limitation, the installer, contractor,...

 Open the catalog to page 8
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.