Building Has Evolved
16Pages

{{requestButtons}}

Catalog excerpts

Building Has Evolved - 1

Building ’ architect builder/developer contractor design professional DURA INTEGRATED BUILDING TECHNOLOGY Building Value

Open the catalog to page 1
Building Has Evolved - 2

•'rrmirrm' Buildings today demand reliable, energy efficient building envelopes that provide superior performance benefits to minimize energy costs, reduce carbon emissions, and maximize property value. NUDURA® structures offer superior strength, storm, sound, and fire resistance and are why the design community, developers and contractors across the world continue to choose NUDURA's Insulated Concrete Forms as a proven alternative to traditional building methods. Our Insulated Concrete Forms provide design professionals, architects, home owners and contractors the freedom and versatility...

Open the catalog to page 2
Building Has Evolved - 3

Norton Pediatric Center innovation makes us the better building choice. the principle is simple. NUDURA Insulated Concrete Forms offer a variety of superior benefits when building a structure. NUDURA ICFs consist of two panels of Expanded Polystyrene (EPS) foam that are 2 5/8” (67mm) in thickness and connected together with our patented web system that is made of 100% recycled material. NUDURA ICFs are stacked, steel reinforced and filled with concrete, which completes the building envelope of your commercial or residential structure in one building step. NUDURA ICFs are available in a...

Open the catalog to page 3
Building Has Evolved - 4

Performance Benefits sustainable building star ts with nudura. maximum energy efficiency. ICFs provide greater energy solutions for any structure. Ongoing laboratory and site testing has proven a home or commercial building built with NUDURA can reduce thermal transfer to as low as 1.9 BTU/ft2/hr (5.99 w/m2 k) even at temperatures as low as -11 deg F (-23 deg C). The energy performance that comes from a NUDURA form is the combination of thermal mass, airtightness and two layers of continuous insulation. Building with NUDURA reduces a building’s operational energy demands up to 60%* and as a...

Open the catalog to page 4
Building Has Evolved - 5

Stabilizing effect of thermal mass on internal temperature. Internal Temperature - NUDURA Wall System Internal Temperature - Traditional Wood Frame External Temperature Room Temperature Peak temperature delayed up to 6 hours Up to 14°F (8°C) difference disaster resilience. Based on no additional mechanical heating or cooling. there’s a lot more to “energy efficiency” than r-value. thermal mass & r-value. The solid mass of the NUDURA wall has some very unique qualities. NUDURA ICFs have a tested R-Value of 24.1 (4.24 RSI) at -31 degrees F outside (-35 degrees C). The monolithic concrete is...

Open the catalog to page 5
Building Has Evolved - 6

Products and Technology First LEED Gold building in Louisville, KY. full thermal envelope exceeds ASHRAE/Standard 90.1-2004 by 20%. Its first year’s energy consumption was 13.6 kBTU/ft2•yr (42.86 kW/m2•yr) and earned an ENERGY STAR rating of 100. For more information visit nudura.com. © CMTA Engineering Consultants NUDURA ICFs are manufactured with industry leading patented technologies that are exclusive to NUDURA, offering you a full line of innovative products designed to provide superior energy efficiency, greater strength, and sound resistance. Our building envelope provides an...

Open the catalog to page 6
Building Has Evolved - 7

for all building types nudura - seres-The NUDURA Wall System completes six building steps with one product: 1. Form system 4. Air barrier 2. Wall structure 5. Vapor control barrier 3. Insulation 6. Interior & exterior fixing points NUDURA offers a form line up that includes 90°, 45°, T forms, Radius forms, Straight (standard) forms, Brick Ledge forms along with a variety of other form combinations to meet the requirements of any design. To meet any building requirement NUDURA ICFs are offered in 4” (100mm), 6” (150mm), 8” (200mm), 10” (250mm) and 12” (300mm) concrete core widths, other...

Open the catalog to page 7
Building Has Evolved - 8

Sustainable Building NUDURA Insulated Concrete Forms Contribute to LEED® The combination of rising energy requirements and fuel costs means that we need to make the most of building technologies to heat and cool commercial structures and homes. NUDURA ICFs provide greater energy solutions for any structure. Ongoing laboratory and site testing has proven a home or commercial building built with NUDURA can reduce thermal transfer to as low as 1.9 BTU/ft2/hr (5.99 w/m2 k) even at temperatures as low as -11 deg F (-23 deg C). A NUDURA home or commercial buildings superior energy performance is...

Open the catalog to page 8
Building Has Evolved - 9

we’ll LEED you to sustainable solutions. ® building a better future. • R ecycled Materials - NUDURA ICFs are manufactured from EPS (Expanded Polystyrene). NUDURA’s unique folding web design is manufactured from 100% recycled polypropylene and steel. • Building Durability - NUDURA forms offer a structure built out of concrete, one of the most durable building materials which result in buildings that stand the test of time. Building with NUDURA means high impact resistance and maximum safety in high wind areas. • Waste Reduction - The unique 4-Way Reversible System from NUDURA creates less...

Open the catalog to page 9
Building Has Evolved - 10

Design Tools & Support service is our foundation for customer satisfaction. technical support & customer service. NUDURA’s manufacturing team has been producing ICFs for over 30 years and continues to play a leading role in developing the industry and in ICF technology. NUDURA aligns itself with the best companies in local geographic areas to provide extensive technical support and service. Distributors can offer installation recommendations to maximize efficiency and cost savings, provide up-to-date code compliance advice for local, regional, and national building codes, as well as product...

Open the catalog to page 10
Building Has Evolved - 11

Training & Continued Education NUDURA Training Academy Learn from our experience. If you are thinking of building with NUDURA Insulated Concrete Forms, we encourage you to take our One Day Basic Installation Training Course. The One day training seminars provide Builders & Installers with basic NUDURA ICF installation skills. NUDURA is committed to providing the highest level of training, ensuring you get the knowledge you need to get the job done with efficiency and confidence. The NUDURA Installation Course is led by a Certified NUDURA Installation Specialist and experienced ICF...

Open the catalog to page 11

All NADURA catalogs and technical brochures

  1. Homega

    2 Pages

  2. Hydrofoam

    2 Pages

  3. Optimizer

    2 Pages

  4. ONE SERIES

    2 Pages

  5. Home owner

    7 Pages

Archived catalogs

  1. Product Guide

    12 Pages