SUNNY CENTRAL 400MV / 500MV / 630MV-1

Turnkey Delivery • Without low-voltage transformer: greater plant efficiency due to direct connection to the mediumvoltage grid • Complete with medium-voltage transformer and concrete substation for outdoor installation • Medium-voltage switchgear systems for a flexible structure of large solar parks • AC transfer station with measurement • Medium-voltage transformers for other grid voltages (deviating from 20 kV) Sunny Central for direct medium-voltage feed-in 400MV / 500MV / 630MV The compact station for safe grid management The station has got it: Equipped with an SMA central inverter of the new HE family and a medium-voltage transformer, the Sunny Central MV feeds directly into the medium-voltage grid. The advantage: By removing the need for the low-voltage transformer, the plant operator realizes greater yields and at the same time lower inverter costs. The Sunny Central MV is delivered as a “turnkey” concrete substation for outside installation. On top of that, the Sunny Central MV actively participates in grid management, and thereby fulfils all requirements of the Medium-Voltage Directive valid as of July 2010.

 Open the catalog to page 1
SUNNY CENTRAL 400MV / 500MV / 630MV-2

SUNNY CENTRAL 400MV / 500MV / 630MV Technical data Input data Nominal DC power Max. DC power MPP voltage range Max. DC voltage Max. DC current Number of DC inputs Output data Nominal AC power @ 45 °C Continuous AC power @ 25 °C Nominal AC voltage Nominal AC current AC grid frequency 50 Hz AC grid frequency 60 Hz Power factor (cos ϕ) Max. THD Power consumption Internal consumption in operation Standby consumption External auxiliary supply voltage External back-up fuse for auxiliary supply Dimensions and weight Height Width Depth Weight Efficiency 2) Max. efficiency Euro-eta Protection rating and...

 Open the catalog to page 2
SUNNY CENTRAL 400MV / 500MV / 630MV-3

Features Display: text line / graphic Ground fault monitoring Heating Emergency stop Circuit breaker AC side Circuit breaker DC side Monitored overvoltage protectors AC / DC Monitored overvoltage protectors for auxiliary supply SCC (Sunny Central Control) interfaces Communication (NET Piggy-Back, optional) Analog inputs Overvoltage protection for analog inputs Sunny String-Monitor connection (COM1) PC connection (COM3) Electrically separated relay (ext. alert signal) Certificates / listings EMC CE conformity BDEW-MSRL / FGW / TR8 6) RD 1633 / 2000 Arrêté du 23/04/08 ● standard features ○ optional...

 Open the catalog to page 3
SUNNY CENTRAL 400MV / 500MV / 630MV-4

Remote controlled power reduction in case of grid overload In order to avoid short-term grid overload, the grid operator presets a nominal active power value which the inverter will implement within 60 seconds. The nominal value is transmitted to the inverters via a ripple control receiver in combination with the SMA Power Reducer Box. Typical limit values are 100, 60, 30 or 0 per cent of the nominal power. Frequency-dependent control of active power As of a grid frequency of 50.2 Hz, the inverter automatically reduces the fed-in of active power according to a definable characteristic curve which...

 Open the catalog to page 4
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.