SUNNY CENTRAL 400HE / 500HE / 630HE
4Pages

{{requestButtons}}

Catalog excerpts

SUNNY CENTRAL 400HE / 500HE / 630HE - 1

High yields • Excellent specific price • Full nominal power up to 50 °C • 10 % additional power in continuous operation at ambient temperatures up to 25 °C • Efficiency of more than 98 percent • Integrated DC main distribution for direct connection of the String-Monitors • Flexible plant design due to input voltage up to 1000 V Reliable • Connection of up to two external DC main distributors for diverse system configuration • Comprehensive grid management functions • Perfect monitoring of all PV strings in the field Sunny Central 400HE / 500HE / 630HE Proven high performance High flexibility in plant design and minimal systems costs with even more power: the proven High Efficiency series for direct connection to the medium-voltage transformer has once again been improved and is already equipped with the intelligent power management of the succeeding generation. This means that maximum power in continuous operation has been increased by ten percent compared to the nominal power for as long as the ambient temperature does not exceed 25 °C. At the same time, the devices offer comprehensive grid management functions – including immediate reconnection after a grid voltage drop.

Open the catalog to page 1
SUNNY CENTRAL 400HE / 500HE / 630HE - 2

SUNNY CENTRAL 400HE / 500HE / 630HE Technical data Input data Nominal DC power Max. DC power MPP voltage range Max. DC voltage Max. DC current Number of DC inputs Output data Nominal AC power @ 50 °C Continuous AC power @ 25 °C Nominal AC voltage ± 10 % Nominal AC current AC grid frequency 50 Hz AC grid frequency 60 Hz Power factor (cos ϕ) Max. THD Power consumption Internal consumption in operation Standby consumption External auxiliary supply voltage External back-up fuse for auxiliary supply Dimensions and weight Height Width Depth Weight Efficiency 2) Max. efficiency Euro-eta Protection...

Open the catalog to page 2
SUNNY CENTRAL 400HE / 500HE / 630HE - 3

Display: text line / graphic Ground fault monitoring Emergency stop Circuit breaker AC side Circuit breaker DC side Monitored overvoltage protectors AC / DC Monitored overvoltage protectors for auxiliary supply SCC (Sunny Central Control) interfaces Communication [NET Piggy-Back, optional} Analog inputs Overvoltage protection for analog inputs Sunny String-Monitor connection [COM 1} Electrically separated relay [ext. alert signal} Certificates / listings • standard features O optional features — not available Type designation SI load disconnection switch with motor SI load disconnection...

Open the catalog to page 3
SUNNY CENTRAL 400HE / 500HE / 630HE - 4

Remote controlled power reduction in case of grid overload In order to avoid short-term grid overload, the grid operator presets a nominal active power value which the inverter will implement within 60 seconds. The nominal value is transmitted to the inverters via a ripple control receiver in combination with the SMA Power Reducer Box. Typical limit values are 100, 60, 30 or 0 per cent of the nominal power. Frequency-dependent control of active power As of a grid frequency of 50.2 Hz, the inverter automatically reduces the fed-in of active power according to a definable characteristic curve...

Open the catalog to page 4

All Mprime by martifer solar catalogs and technical brochures

  1. SMARTRACKER

    2 Pages