The XRC series heat recuperators are designed for efficient energy recovery in ventilation systems, suitable for environments like shops, offices, and restaurants. They feature a high-efficiency air-air heat exchanger for significant heat recovery from extracted air.
Construction Details:
  • Structure: Made from aluminum profiles and pre-varnished galvanized steel panels, insulated with 15 mm glass wool for acoustic and thermal isolation.
  • Heat Exchanger: Static type with aluminum plates and cross-air flows, separated by sealing.
  • Filters: G4 class supply and extraction filters made of polyester fiber with a metal frame.
  • Ventilators: Centrifugal ventilators with double aspiration, removable for maintenance.
  • Motors: Available in one or three-speed versions, with on-board terminal for electrical connections.
  • Condensation: Galvanized steel basin with discharge.
Accessories:
  • Cooling or heating batteries
  • Speed regulator and switch
  • Electronic control system
  • Supply or extraction grill
  • Air load regulation damper
  • Rain protection roof
  • Base corner support
Performance:
  • Nominal air load and static pressure are specified for each model.
  • Acoustic power levels are provided for open space conditions.
  • Recovery efficiency and thermal power are detailed for each model.
Ventilator Characteristics:
  • Single and three-speed ventilator options with specifications on power, protection level, and isolation class.
Filter Characteristics:
  • G4 filters available as spare parts, with dimensions and filtering efficiency specified.
Post-Heating Coils:
  • Water and electric coils available, with specifications on thermal yield, pressure loss, and dimensions.
Cooling Section:
  • Cooling water batteries designed for specific air and water temperature conditions.
Selection Curves:
  • Graphs show thermal exchange efficiency and static pressure variations with air flow changes.
Control System:
The XRC series includes a control system for managing motors with variable speeds. The control panel CRK, with IP65 protection, includes a remote keyboard and safety features like antifreeze protection and dirty filter warnings.
Technical Characteristics:
The control panel dimensions are 410x285x140 mm, including components like circuit breakers, fuses, and transformers. The electronic control type NK109 manages ambient temperature, humidity, free cooling, and CO2 levels, supporting modulating batteries and variable speed management.
Visual Signals:
Visual signals indicate motor status, clogged filters, and frost protection for efficient operation and maintenance.
Protection and Alarms:
General signs and alarms ensure safety and proper functioning, with sensors for flow temperature, room temperature, and antifreeze temperature.
Construction Features:
The system is housed in a PVC box with 18 modules, offering IP 65 protection, operating on a 230V, single-phase, 50Hz power supply. Wiring diagrams and a 'Declaration of Conformity' are provided according to European Directives and EN 60439-1 standards.
Complete Regulation System:
Designed for compact base models suitable for tri-phase motors with a maximum power of 4 kW, supporting 1 to 3 speeds and absorption above 10 A. The control panel is encased in a tin containment casing with IP55 protection, controlled via remote or infrared keypad.
Heat Recuperators:
The XRC series controls two single-phase motors at variable speeds, supporting modular control of temperature for three-way valves and electric batteries.
Additions for Regulation Systems:
Models offer variable speed absorption with maximum amperage options (6, 10, 20 A) and inverter capabilities. Accessories include three-way valves for cooling and post-heating water coils, and controls for electric batteries.
Accessories:
Additional accessories include pressurestats for blocked filters, proportional humidification probes, and room electrical controls. Optional features include on-off defrost probes and signage lights.
Application Example:
Components include flowstat, antifreeze thermostat, differential pressurestat, supply temperature, room temperature, and external temperature sensors for free cooling applications.
See more

Catalog excerpts

XRC Series-1

HEAT RECUPERATORS WITH AIR-AIR CROSS FLOW OVERVIEW AND CONSTRUCTION DETAILS OVERVIEW : The XRC series of heat recuperators are fitted with a highly efficient air-air heat exchanger that makes it possible to reuse a significant amount of the heat present in the extracted air. It is therefore suitable for all those installations where a significant amount of heat can be recovered thereby making energy savings, such as in ventilation systems in shops, offices, catering premises, bars and restaurants. CONSTRUCTION DETAILS: - The XRC model is made with an aluminium profile structure and box shape panels of prevarnished galvanized steel, internally isolated with glass wool having an average thickness of 15 mm, ideal to guarantee the maximum results for acoustic and thermal isolation with density greater than than 120 Kg/m³. - Static type heat exchanger, highly efficient, made with aluminium plates using cross-air flows kept separate by a suitable sealing. - G4 class supply and extraction filter elements, wavy model, in polyester fibre with a metal frame and electrically welded containment net with purposely ideated slots to facilitate maintenance and periodic substitution. - Supply and extraction centrifugal ventilators with double aspiration removable on each side of the unit for frequent maintenance. - One or three speed electric motors directly coupled, usually available in stock 1 speed version. - On board terminal for electrical connections and ventilators control. I nom [A] - Condensation collecting basin nr fasi - Alimentzione [V] in galvanized steel with condensation discharge. ACCESSORIES : Cooling or heating batteries. Speed regulator and switch. Electronic control system. Supply or extraction grill. Air load regulation damper. Rain protection roof. Base corner support. XRC MODEL DETAIL OF VENTILATOR INSPECTION DOOR DETAIL OF A MODEL MADE TO CUSTOMER REQUESTS XRC MODEL DETAIL FILTER SUBSTITUTION DOOR

 Open the catalog to page 1
XRC Series-2

HEAT RECUPERATORS WITH AIR-AIR CROSS FLOW CONSTRUCTION DIMENTIONSXRC & XRCE MODEL - PRODUCTION DRAWING MODEL

 Open the catalog to page 2
XRC Series-3

HEAT RECUPERATORS WITH AIR-AIR CROSS FLOW HORIZONTAL CONFIGUTATIONS THE HORIZONTAL CONFIGURATIONS ARE FROM ABOVE VIEW K1 CONFIGURATION (HORIZONTAL) OTHER CONFIGURATIONS ON REQUEST

 Open the catalog to page 3
XRC Series-4

HEAT RECUPERATORS WITH AIR-AIR CROSS FLOW HORIZONTAL CONFIGUTATIONS THE SHOWN VERTICAL CONFIGURATIONS ARE SIDE-ON VIEW. K9 CONFIGURATION (VERTICAL) SIDE AND FRONT INSPECTION K10 CONFIGURATION (VERTICAL) SIDE AND FRONT INSPECTION FREE-COOLING CONFIGURATION (HORIZONTAL) OTHER CONFIGURATIONS UPON REQUEST

 Open the catalog to page 4
XRC Series-5

HEAT RECUPERATORS WITH AIR-AIR CROSS FLOW PERFORMANCE The data in the tables indicate the performance for a nominal air load. The variantion in performance air load described below in relation to the size of the recuperator, is described in the tables at the end of this chapter. The graphs for the curves of the ventilators are available upon request from our Technical Department. XRC - XRCE RECUPERATORS GENERAL CHARACTERISTICS (*) Evaluated performances with nominal air load temperature on exit of 20 °C and fresh air at -5 °C. (**) Generated noise power of each ventilator in an open space at...

 Open the catalog to page 5
XRC Series-6

HEAT RECUPERATORS WITH AIR-AIR CROSS FLOW VENTILATORS SINGLE SPEED VENTILATOR CHARACTERISTICS EACH RECUPERATOR HOUSES TWO VENTILATORS (*) Evaluated performances with nominal air load temperature on exit of 20 °C and fresh air at -5 °C. (**) Irradiated noise without dampening of panels.

 Open the catalog to page 6
XRC Series-7

HEAT RECUPERATORS WITH AIR-AIR CROSS FLOW ACCESSORIES G4 FILTER CHARACTERISTICS Normally available in stock as spare parts.

 Open the catalog to page 7
XRC Series-8

HEAT RECUPERATORS WITH AIR-AIR CROSS FLOW ACCESSORIES POST-HEATING WATER COILS XRC and XRCE NORMALLY INSTALLED INSIDE THE RECUPERATOR Sizes chosen with the foolowing conditions: immitted air at 8 °C, nominal air load. stage heat coil on request

 Open the catalog to page 8
XRC Series-9

HEAT RECUPERATORS WITH AIR-AIR CROSS FLOW ACCESSORIES VARIATOR FOR SINGLE SPEED MOTORS (TWO PER UNIT) Specific for three-phase motors

 Open the catalog to page 9
XRC Series-10

HEAT RECUPERATORS WITH AIR-AIR CROSS FLOW ACCESSORIES XRC SERIES RECUPERATOR MODEL 50mm PITCH GRILLES WITH BIRD NET

 Open the catalog to page 10
XRC Series-11

HEAT RECUPERATORS WITH AIR-AIR CROSS FLOW ACCESSORIES BASE CORNER SUPPORTS (*) (*) It can be installed in recuperators with a vertical configuration or in those versions with a horizontal configuratioN for floors versions. 4 corner supports in galanized steel H 100mm.

 Open the catalog to page 11
XRC Series-12

HEAT RECUPERATORS WITH AIR-AIR CROSS FLOW ACCESSORIES COOLING SECTION : Allows cooling and the possibility of dehumidifying the air on exit from the recuperator unit. An exchange battery is used with copper tubing and and aluminium pack with a collection basin in galvanized steel. The unit is boxed in a special aluminium profile casing and a dobble panel, sandwich, system insulated with glass wool. The characteristics of the frame allow the unit to be fixed into place in linear square air ducts. WATER COOLED BATTERIES XRC e XRCE

 Open the catalog to page 12
XRC Series-13

HEAT RECUPERATORS WITH AIR-AIR CROSS FLOW SELECTION CURVES MODEL 03 Thermal exchange efficiency. By varying the air flow, it is possible to obtain different efficiency values for the thermal exchange. The air flow can be adjusted both with regulatting the dampers and by varying the revolutions of the motors. Single speed version. Available static pressure and power absorption. By varying the air flow, it is possible to obtain different static pressure values for the injected air. The dotted line on the diagram also indicates the power absorption for the correct size of the power supply system....

 Open the catalog to page 13
XRC Series-14

HEAT RECUPERATORS WITH AIR-AIR CROSS FLOW SELECTION CURVES MODEL 05 Thermal exchange efficiency. By varying the air flow, it is possible to obtain different efficiency values for the thermal exchange. The air flow can be adjusted both with regulatting the dampers and by varying the revolutions of the motors. Single speed version. Available static pressure and power absorption. By varying the air flow, it is possible to obtain different static pressure values for the injected air. The d tt d li Th dotted line on the diagram also th di l indicates the power absorption for the correct size of the...

 Open the catalog to page 14

Archived catalogs

  1. VAV & CAV

    48  Pages

  2. fire protection

    12  Pages

  3. fans

    32  Pages

  4. silencers

    20  Pages

  5. regulation

    20  Pages

  6. diffusion

    132  Pages

  7. recuperators

    6  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.