video corpo

XRC Series
26Pages

{{requestButtons}}

Catalog excerpts

XRC Series - 1

HEAT RECUPERATORS WITH AIR-AIR CROSS FLOW OVERVIEW AND CONSTRUCTION DETAILS OVERVIEW : The XRC series of heat recuperators are fitted with a highly efficient air-air heat exchanger that makes it possible to reuse a significant amount of the heat present in the extracted air. It is therefore suitable for all those installations where a significant amount of heat can be recovered thereby making energy savings, such as in ventilation systems in shops, offices, catering premises, bars and restaurants. CONSTRUCTION DETAILS: - The XRC model is made with an aluminium profile structure and box shape panels of prevarnished galvanized steel, internally isolated with glass wool having an average thickness of 15 mm, ideal to guarantee the maximum results for acoustic and thermal isolation with density greater than than 120 Kg/m³. - Static type heat exchanger, highly efficient, made with aluminium plates using cross-air flows kept separate by a suitable sealing. - G4 class supply and extraction filter elements, wavy model, in polyester fibre with a metal frame and electrically welded containment net with purposely ideated slots to facilitate maintenance and periodic substitution. - Supply and extraction centrifugal ventilators with double aspiration removable on each side of the unit for frequent maintenance. - One or three speed electric motors directly coupled, usually available in stock 1 speed version. - On board terminal for electrical connections and ventilators control. I nom [A] - Condensation collecting basin nr fasi - Alimentzione [V] in galvanized steel with condensation discharge. ACCESSORIES : Cooling or heating batteries. Speed regulator and switch. Electronic control system. Supply or extraction grill. Air load regulation damper. Rain protection roof. Base corner support. XRC MODEL DETAIL OF VENTILATOR INSPECTION DOOR DETAIL OF A MODEL MADE TO CUSTOMER REQUESTS XRC MODEL DETAIL FILTER SUBSTITUTION DOOR

Open the catalog to page 1
XRC Series - 2

HEAT RECUPERATORS WITH AIR-AIR CROSS FLOW CONSTRUCTION DIMENTIONSXRC & XRCE MODEL - PRODUCTION DRAWING MODEL

Open the catalog to page 2
XRC Series - 3

HEAT RECUPERATORS WITH AIR-AIR CROSS FLOW HORIZONTAL CONFIGUTATIONS THE HORIZONTAL CONFIGURATIONS ARE FROM ABOVE VIEW K1 CONFIGURATION (HORIZONTAL) OTHER CONFIGURATIONS ON REQUEST

Open the catalog to page 3
XRC Series - 4

HEAT RECUPERATORS WITH AIR-AIR CROSS FLOW HORIZONTAL CONFIGUTATIONS THE SHOWN VERTICAL CONFIGURATIONS ARE SIDE-ON VIEW. K9 CONFIGURATION (VERTICAL) SIDE AND FRONT INSPECTION K10 CONFIGURATION (VERTICAL) SIDE AND FRONT INSPECTION FREE-COOLING CONFIGURATION (HORIZONTAL) OTHER CONFIGURATIONS UPON REQUEST

Open the catalog to page 4
XRC Series - 5

HEAT RECUPERATORS WITH AIR-AIR CROSS FLOW PERFORMANCE The data in the tables indicate the performance for a nominal air load. The variantion in performance air load described below in relation to the size of the recuperator, is described in the tables at the end of this chapter. The graphs for the curves of the ventilators are available upon request from our Technical Department. XRC - XRCE RECUPERATORS GENERAL CHARACTERISTICS (*) Evaluated performances with nominal air load temperature on exit of 20 °C and fresh air at -5 °C. (**) Generated noise power of each ventilator in an open space...

Open the catalog to page 5
XRC Series - 6

HEAT RECUPERATORS WITH AIR-AIR CROSS FLOW VENTILATORS SINGLE SPEED VENTILATOR CHARACTERISTICS EACH RECUPERATOR HOUSES TWO VENTILATORS (*) Evaluated performances with nominal air load temperature on exit of 20 °C and fresh air at -5 °C. (**) Irradiated noise without dampening of panels.

Open the catalog to page 6
XRC Series - 7

HEAT RECUPERATORS WITH AIR-AIR CROSS FLOW ACCESSORIES G4 FILTER CHARACTERISTICS Normally available in stock as spare parts.

Open the catalog to page 7
XRC Series - 8

HEAT RECUPERATORS WITH AIR-AIR CROSS FLOW ACCESSORIES POST-HEATING WATER COILS XRC and XRCE NORMALLY INSTALLED INSIDE THE RECUPERATOR Sizes chosen with the foolowing conditions: immitted air at 8 °C, nominal air load. stage heat coil on request

Open the catalog to page 8
XRC Series - 9

HEAT RECUPERATORS WITH AIR-AIR CROSS FLOW ACCESSORIES VARIATOR FOR SINGLE SPEED MOTORS (TWO PER UNIT) Specific for three-phase motors

Open the catalog to page 9
XRC Series - 10

HEAT RECUPERATORS WITH AIR-AIR CROSS FLOW ACCESSORIES XRC SERIES RECUPERATOR MODEL 50mm PITCH GRILLES WITH BIRD NET

Open the catalog to page 10
XRC Series - 11

HEAT RECUPERATORS WITH AIR-AIR CROSS FLOW ACCESSORIES BASE CORNER SUPPORTS (*) (*) It can be installed in recuperators with a vertical configuration or in those versions with a horizontal configuratioN for floors versions. 4 corner supports in galanized steel H 100mm.

Open the catalog to page 11
XRC Series - 12

HEAT RECUPERATORS WITH AIR-AIR CROSS FLOW ACCESSORIES COOLING SECTION : Allows cooling and the possibility of dehumidifying the air on exit from the recuperator unit. An exchange battery is used with copper tubing and and aluminium pack with a collection basin in galvanized steel. The unit is boxed in a special aluminium profile casing and a dobble panel, sandwich, system insulated with glass wool. The characteristics of the frame allow the unit to be fixed into place in linear square air ducts. WATER COOLED BATTERIES XRC e XRCE

Open the catalog to page 12
XRC Series - 13

HEAT RECUPERATORS WITH AIR-AIR CROSS FLOW SELECTION CURVES MODEL 03 Thermal exchange efficiency. By varying the air flow, it is possible to obtain different efficiency values for the thermal exchange. The air flow can be adjusted both with regulatting the dampers and by varying the revolutions of the motors. Single speed version. Available static pressure and power absorption. By varying the air flow, it is possible to obtain different static pressure values for the injected air. The dotted line on the diagram also indicates the power absorption for the correct size of the power supply...

Open the catalog to page 13
XRC Series - 14

HEAT RECUPERATORS WITH AIR-AIR CROSS FLOW SELECTION CURVES MODEL 05 Thermal exchange efficiency. By varying the air flow, it is possible to obtain different efficiency values for the thermal exchange. The air flow can be adjusted both with regulatting the dampers and by varying the revolutions of the motors. Single speed version. Available static pressure and power absorption. By varying the air flow, it is possible to obtain different static pressure values for the injected air. The d tt d li Th dotted line on the diagram also th di l indicates the power absorption for the correct size of...

Open the catalog to page 14

All MP3 catalogs and technical brochures

  1. UV SERIES

    6 Pages

  2. FLEXIBLE DUCTS

    18 Pages

  3. TT Series

    6 Pages

  4. SA2 Series

    5 Pages

  5. SAC Series

    5 Pages

  6. XXP Series

    4 Pages

  7. XTE Series

    2 Pages

  8. AS-TN Series

    6 Pages

  9. XZO Series

    4 Pages

  10. XE Series

    2 Pages

  11. XZJ Series

    2 Pages

  12. XSR Series

    4 Pages

  13. FTR Series

    2 Pages

  14. FA Series

    2 Pages

  15. FP

    1 Pages

  16. FTF

    2 Pages

  17. XUM

    4 Pages

  18. XLA-C

    2 Pages

  19. XLF

    6 Pages

  20. diffusion

    30 Pages

  21. VAV and CAV

    82 Pages

  22. Regulation

    38 Pages

  23. Recuperators

    26 Pages

  24. Humidifiers

    6 Pages

  25. Fans

    58 Pages

  26. Silenciers

    20 Pages

  27. Filtering

    26 Pages

Archived catalogs

  1. silencers

    20 Pages

  2. VAV & CAV

    48 Pages

  3. diffusion

    132 Pages

  4. regulation

    20 Pages

  5. fans

    32 Pages

  6. recuperators

    6 Pages