Catalog excerpts
FLEXIBLE DUCTS TT SERIES OVERVIEW MANUFACTURING CHARACTERISTICS (*) Class 1-1 and Class 1 are equivalent, he attribution of one or the other depends on the date of certification GREENGUARD The flexible ducts with internal in alluminium TTO- TT1- TT2- TT3 have obtained classification of products with low release GREENGUARD Indoor Air Quality Certification e GREENGUARD Children and School Certification Those ducts so brovide te maximum salubrity of the air inside the rooms. OVERVIEW : The new range of flexible ducts in aluminium polyester part of the TT series, form a wide range of accessories for the distribution and connection of the principal aeraulic network with the end terminals in HVAC systems. The use of these flexible ducts allow an easy, rapid and economic installation in the different types of civil and industrial systems, satisfying the latest and most recent Italian fire prevention normatives, both in public and private dwellings. The TT series range has been devised to satisfy different usage requirements and more precisely: - TTO Used in the extraction or conditioning of air, satisfies the requirements of robustness to tractioning and against tearing. The insulation against vapour and condensation in all those cases where Fire Class 0 is required. Available antibacterial type for hospitals. - TT1 Used in the extraction or conditioning of air, satisfies the requirements of robustness to tractioning and against tearing. The insulation against vapour and condensation in all those cases where Fire Class 1-1 is required. Available antibacterial type for hospitals. - TT2/TT02 Used in the extraction or condition of air, satisfies the requirements of mechanical resistance, insulation against vapour and condensations with a specific and aimed reduction in noise produced by a micro puncture in the main internal duct in all those cases where the Fire Class 1-1 or Class 1 is required. (*) - TT3 Used in the extraction or conditioning of air, satisfies the requirements of robustness to tractioning and against tearing in all those cases in which the Fire Class 1-1 is requested. Available antibacterial type for hospitals. - TT4/TT6 Used in the extraction or conditioning of air, satisfies the requirements of robustness to tractioning and against and tearing. The insulation against vapour and condensation in all those cases where the Fire Class 1 is requested. - TT7 Used in the extraction or conditioning of air, satisfies the requirements of robustness to tractioning and against and tearing. The insulation against vapour and condensation in all those cases where the Fire Class 1 is requested. - TT8 Used in the extraction or conditioning of air, its main characteristic is the insulation in polyester and satisfies the requirements of robustness to tractioning and against and tearing. The insulation against vapour and condensation in all those cases where the Fire Class 1 is requested. - TT10 Used in the extraction of air, is characterized by the structutre in polyester mesh covered both sides with film in PVC. Satisfies the requirements of robustness to tractioning and against and tearing, suitable in all those cases in which the Fire Class 1 is requested. - TT11 Used in the extraction or conditioning of air, is characterized by the structutre in in polyester mesh covered both sides with film in PVC insulated by a polyester mat and by an external jacket in polyetylene. Satisfies the requirements of robustness to tractioning and against and tearing, suitable in all those cases in which the Fire Class 1 is requested. IMPORTANT: For flexible ducts have not yet issued a European standard that wifi allow the euro-class fire classification classification. Consequently: they are certified according to Italian standards and lows; they cannot be marked CE. Before performing installations outside of Italy, it is urged to deepen the legal and regulatory aspects with local engineers to avoid job-related disputes.
Open the catalog to page 1FLEXIBLE DUCTS TT SERIES OVERVIEW MANUFACTURING CHARACTERISTICS BUILD CHARACTERISTICS: Insulated flexible duct TT 0 Made with an internal duct consisting of an harmonic steel spiral wrapped by two multilayer laminates aluminum/polyester 74pm. Insulating mat made of glass-fiber density 18 kg/m3 and thickness 25 mm. External cover in aluminum/polyester 49pm. Available in antibacterial for hospital use. Reaction to fire class 0 Certified CSI 0274/04/RF Approval PD2229NNNNN000005 Insulated flexible duct TT 1 Made with an internal duct consisting of an harmonic steel spiral wrapped by two...
Open the catalog to page 2FLEXIBLE DUCTS OVERVIEW MANUFACTURING CHARACTERISTICS FLEXIBLE DUCT TT 2 -TT02 - ACOUSTIC CHARACTERISTICS : By acoustic reduction is meant the difference between the values at the top and at the bottom of the duct. Lwl Lw2 By acoustic absorbtion is meant the difference between the irradiated values and the values at values at the top of the duct. J Accessories-vers. 17.00.xls Acoustic reduction (dB) [Lwl - Lw3]
Open the catalog to page 3FLEXIBLE DUCTS SERIES TT TECHINCAL CHARACTERISTICS LOCAL PRESSURE DROPS : Additional length per R/D bend - 1 The pressure drops in the bends are calculated using the "equivalent length" method, i.e. the length of a linear duct with pressure drops equal to the bend (refer to the table alongside). The equivalent length can be taken from the table alongside:. Example : Given a flexible pipe measuring 4 m, with a rated diameter of 203 mm, with a 90° bend and R/D=i, establish the overall pressure drop for an airflow of 580 m3/h. From the table: equivalent length = 2.03 m total length = 4 + 2.03...
Open the catalog to page 4FLEXIBLE DUCTS
Open the catalog to page 5All MP3 catalogs and technical brochures
-
UV SERIES
6 Pages
-
EXTERNAL INDUSTRIAL GRILLES
14 Pages
-
FLEXIBLE DUCTS
18 Pages
-
floor diffusers
30 Pages
-
AT-RPR Series
7 Pages
-
SA2 Series
5 Pages
-
SAC Series
5 Pages
-
XRC Series
26 Pages
-
XXP Series
4 Pages
-
XTE Series
2 Pages
-
AS-TN Series
6 Pages
-
XZO Series
4 Pages
-
XE Series
2 Pages
-
XZJ Series
2 Pages
-
XSR Series
4 Pages
-
FTR Series
2 Pages
-
PP 30F Series
4 Pages
-
FA Series
2 Pages
-
FP
1 Pages
-
FTF
2 Pages
-
XUM
4 Pages
-
XLA-C
2 Pages
-
XLF
6 Pages
-
FIXED CONES CIRCULAR DIFFUSERS
72 Pages
-
VENTILATION GRILLES
24 Pages
-
diffusion
30 Pages
-
VAV and CAV
82 Pages
-
Regulation
38 Pages
-
Air curtain barrier
42 Pages
-
floor diffusers
22 Pages
-
Recuperators
26 Pages
-
Air-curtain barrier
18 Pages
-
Humidifiers
6 Pages
-
Fans
58 Pages
-
Silenciers
20 Pages
-
Filtering
26 Pages
Archived catalogs
-
silencers
20 Pages
-
VAV & CAV
48 Pages
-
diffusion
132 Pages
-
regulation
20 Pages
-
fire protection
12 Pages
-
air-curtain barriers
10 Pages
-
fans
32 Pages
-
humidification
4 Pages
-
recuperators
6 Pages