Regulation
38Pages

{{requestButtons}}

Catalog excerpts

Regulation - 1

PRESSURE-OPPERATED DAMPER PITCH 50 FOR WALL OVERVIEW AND TECHNICAL DATA TECHNICAL DATA: Damper and grille frame (if present) Extruded anodized aluminium, width 25 mm, rounded edge. Blades In aluminium with pitch 50 mm, fixed with hinges on nylon wrist inserted on frame. Blades of grille (if present) In extruded anodized aluminium with 20mm pitch, fixed with wrist in a nylon self-locking lane inserted in the frame. Transversal reinforcement: all dampers having size B over 1000 mm. Counter frame Rigid in steal. Mounting on the wall Without screws but clips and counter frame or in the traditional way with screws in wall or channel. Finishing In natural aluminium. PRESSURE OPERATED DAMPER FOR VENTILATION WSI OVERVIEW: The WS series dampers are used to maintain overpressure or under pressure in premises or apartments; they can be used for in air conditioning, ventilation and heating systems. This type of damper can be supplied with an extraction grille with a 20 mm pitch or a net both already mounted. For the intake-model the net is replaced with a square mesh grille for external use, because of the higher strength and the better aspect. PRESSURE OPERATED DAMPER FOR VENTILATION WSE ACCESSORY: ANTI-NOISE SEALING

Open the catalog to page 1
Regulation - 2

PRESSURE-OPPERATED DAMPER PITCH 50 FOR WALL PRESSURE-OPERATED DAMPER FOR INTAKE WITH GRILLE WSI + UR PRESSURE-OPERATED DAMPER FOR VENTILATION WITH GRILLE WSE + UR 137 PRESSURE-OPERATED DAMPER FOR INTAKE WITH GRILLE WSI + UQ PRESSURE-OPERATED DAMPER FOR VENTILATION WITH NET WSE + RE

Open the catalog to page 2
Regulation - 3

PRESSURE-OPPERATED DAMPER -1 WS Pressure opperated damper Standard bases Standard Haights ^^^^r^ advanced air toEutloni

Open the catalog to page 3
Regulation - 4

^■i^^^^r advanced air solutions

Open the catalog to page 4
Regulation - 5

PRESSURE-OPERATED DAMPER FOR DUCT OVERVIEW: The WCS series dampers enable the flow of air in a natural single direction when a difference of pressure between the two sides exits. The blades are free to move on the wrist enabling the flow of air. Once this is achieved the blades shut simply by with the force of gravity. CHARACTERISTICS: Frame : in extruded aluminium, 120 mm wide, made in 4 parts assembled together mechanically. Blades : in aluminium with pitch 100 mm (up to height 600 mm pitch 50 mm). Execution : with flanges for channel. Grille (on request) : in aluminium pitch 50 mm SIZES...

Open the catalog to page 5
Regulation - 6

PRESSURE-OPERATED DAMPER FOR DUCT Speed per channel: 2 m/s Hight Speed per channel: 3,5 m/s Hight

Open the catalog to page 6
Regulation - 7

PRESSURE-OPERATED DAMPER FOR DUCT Speed per channel: 5 m/s Hight Speed per channel: 6,5 m/s Hight

Open the catalog to page 7
Regulation - 8

PRESSURE-OPERATED DAMPER -1 WCS Pressure opperated damper for duct ^^^^r^ advanced air toEutloni

Open the catalog to page 8
Regulation - 9

CONTROL DAMPERS PITCH 100 mm OVERVIEW TECHNICAL DIAGRAMS OVERVIEW : WM-10 control dampers are a new series of products from the WM series. The WM-10 series of control dampers are suitable for the application on square and rectangular ducts. The control of these dampers can be manual, electric or pneumatic, according to the needs of the ventilation system. The installation of these components allows the control of the air flow rate variation (VAV) or the pressure variation control on several kinds of plants. Specifically: WM-10 control damper is new in its type due to the innovative movement...

Open the catalog to page 9
Regulation - 10

CONTROL DAMPERS PITCH 100 mm TECHNICAL DATA NSTALLATION PROCEDURE CHARACTERISTICS : Damper Mobile closing system mounted into an air duct, designed to control and close air flow. Mounting By screws through damper flange and duct flange or by selfthreading screws through damper flange and air-treatment unit panel. MOUNTING SYSTEM : Frame, materials and construction method The frame is manufactured in extruded aluminium and designed to withstand the lateral stress from to air pressure, and built with lateral frame to protect the drive gears. Damper mounted inside (figure n°2) or at the...

Open the catalog to page 10
Regulation - 11

CONTROL DAMPERS AIR FLOW RATE - PRESSURE DROP BLADES REGULATION - DAMPER SECTION CONTROL DAMPER ON FIGURE No. 1 a) Control damper positioned as figure No. 2 d) Blades deflection angle on opening a = 47° a) Control damper positioned as figure No. 3 c) Blades deflection angle on opening a = 30° ^^^^r^ advanced air toEutloni

Open the catalog to page 11
Regulation - 12

CONTROL DAMPERS PITCH 100 mm ACOUSTIC LEVEL MANUAL CONTROL SYSTEM ELECTRIC CONTROL SYSTEM ACOUSTIC POWER LEVEL The diagram shows the values of acoustic level in dB(A) as a result of the frontal velocity and pressure drop. The acoustic levels found on the diagram are relative to an air section 1 m². For other sections see correction factor K in below table. CALCULATION EXAMPLE: a) values as shown in figure No.1 b) Calculate the result between velocity V(m/s) x pressure drop rp (Pa) with result 5 x 53 = 265 CORRECTION FACTOR "K" OF ACOUSTIC LEVEL Section in m2 K (dB) Mechanism, manual...

Open the catalog to page 12
Regulation - 13

CONTROL DAMPERS PITCH 100 mm WM Control damper 10 pitch 100 mm C with manual command P with hinge Base Haight

Open the catalog to page 13
Regulation - 14

CONTROL DAMPERS PITCH 100 mm Aluminium graduated plate for attuator support. Fixing leaver with fixing bolt, complete with knob for graduated plate for motor support. Complete manual command kit, compelte with graduated plate, actioning lever, fixing bolt and knob.

Open the catalog to page 14
Regulation - 15

CONTROL DAMPERS 50mm PITCH OVERVIEW : The WM-05 series forms a new range do calibration dampers. These dampers are used in ventilation systems and for the regulation of the air distribution in the network. The regulation of the air flow is managed from a manual command able to regulate the blade inclination (WM-05C). In alternative the damper can be equipped with an electric servomotor that can be controlled by the individual themselves (WM-05P). With this scope, a version has also been designed with a control hinge, as shown in the diagrams here below shown. CHARACTERISTICS: Frame:...

Open the catalog to page 15
Regulation - 16

CONTROL DAMPERS 50mm PITCH The graphs and diagrams shown, refer to the pressure loss with reference to the speed of the air and of the inclination of the blades and in the same way the relative noise levels of the single unit. For different areas to the ones shown, the correcting factor K must be added. Section speed BxH Section area BxH Total pressure loss 2 Sound level pondered in A for 1 m Winglet angle 2 Correction factor for S ≠ 1 m CORRECTION FACTOR FOE SECTION - K [dB(A)] 2 0,005 0,010 0,020 0,050 BxH [m ] K [dB(A)] -23 -20 -17 -13

Open the catalog to page 16

All MP3 catalogs and technical brochures

  1. UV SERIES

    6 Pages

  2. FLEXIBLE DUCTS

    18 Pages

  3. TT Series

    6 Pages

  4. SA2 Series

    5 Pages

  5. SAC Series

    5 Pages

  6. XRC Series

    26 Pages

  7. XXP Series

    4 Pages

  8. XTE Series

    2 Pages

  9. AS-TN Series

    6 Pages

  10. XZO Series

    4 Pages

  11. XE Series

    2 Pages

  12. XZJ Series

    2 Pages

  13. XSR Series

    4 Pages

  14. FTR Series

    2 Pages

  15. FA Series

    2 Pages

  16. FP

    1 Pages

  17. FTF

    2 Pages

  18. XUM

    4 Pages

  19. XLA-C

    2 Pages

  20. XLF

    6 Pages

  21. diffusion

    30 Pages

  22. VAV and CAV

    82 Pages

  23. Recuperators

    26 Pages

  24. Humidifiers

    6 Pages

  25. Fans

    58 Pages

  26. Silenciers

    20 Pages

  27. Filtering

    26 Pages

Archived catalogs

  1. silencers

    20 Pages

  2. VAV & CAV

    48 Pages

  3. diffusion

    132 Pages

  4. regulation

    20 Pages

  5. fans

    32 Pages

  6. recuperators

    6 Pages