Catalog excerpts
HEAT RECUPERATORS WITH AIR-AIR CROSS FLOW OVERVIEW AND CONSTRUCTION DETAILS OVERVIEW : The XRC series of heat recuperators are fitted with a highly efficient air-air heat exchanger that makes it possible to reuse a significant amount of the heat present in the extracted air. It is therefore suitable for all those installations where a significant amount of heat can be recovered thereby making energy savings, such as in ventilation systems in shops, offices, catering premises, bars and restaurants. CONSTRUCTION DETAILS: - The XRC model is made with an aluminium profile structure and box shape panels of prevarnished galvanized steel, internally isolated with glass wool having an average thickness of 15 mm, ideal to guarantee the maximum results for acoustic and thermal isolation with density greater than than 120 Kg/m³. - Static type heat exchanger, highly efficient, made with aluminium plates using cross-air flows kept separate by a suitable sealing. - G4 class supply and extraction filter elements, wavy model, in polyester fibre with a metal frame and electrically welded containment net with purposely ideated slots to facilitate maintenance and periodic substitution. - Supply and extraction centrifugal ventilators with double aspiration removable on each side of the unit for frequent maintenance. - One or three speed electric motors directly coupled, usually available in stock 1 speed version. - On board terminal for electrical connections and ventilators control. I nom [A] - Condensation collecting basin nr fasi - Alimentzione [V] in galvanized steel with condensation discharge. ACCESSORIES : Cooling or heating batteries. Speed regulator and switch. Electronic control system. Supply or extraction grill. Air load regulation damper. Rain protection roof. Base corner support. XRC MODEL DETAIL OF VENTILATOR INSPECTION DOOR DETAIL OF A MODEL MADE TO CUSTOMER REQUESTS XRC MODEL DETAIL FILTER SUBSTITUTION DOOR
Open the catalog to page 1HEAT RECUPERATORS WITH AIR-AIR CROSS FLOW CONSTRUCTION DIMENTIONS XRC & XRCE MODEL - PRODUCTION DRAWING
Open the catalog to page 2HEAT RECUPERATORS WITH AIR-AIR CROSS FLOW HORIZONTAL CONFIGUTATIONS THE HORIZONTAL CONFIGURATIONS ARE FROM ABOVE VIEW OTHER CONFIGURATIONS ON REQUEST
Open the catalog to page 3HEAT RECUPERATORS WITH AIR-AIR CROSS FLOW HORIZONTAL CONFIGUTATIONS THE SHOWN VERTICAL CONFIGURATIONS ARE SIDE-ON VIEW. MANDATA ESPULSIONE OTHER CONFIGURATIONS UPON REQUEST
Open the catalog to page 4HEAT RECUPERATORS WITH AIR-AIR CROSS FLOW The data in the tables indicate the performance for a nominal air load. The variantion in performance air load described below in relation to the size of the recuperator, is described in the tables at the end of this chapter. The graphs for the curves of the ventilators are available upon request from our Technical Department. XRC - XRCE RECUPERATORS GENERAL CHARACTERISTICS RECUPERATOR MODEL Supply air static pressure (*) [Pa] EXCHANGERS GENERAL CHARACTERISTICS (*) RECUPERATOR MODEL Recovery efficiency [%] Air recovery thermal power [kW] (*)...
Open the catalog to page 5HEAT RECUPERATORS WITH AIR-AIR CROSS FLOW SINGLE SPEED VENTILATOR CHARACTERISTICS EACH RECUPERATOR HOUSES TWO VENTILATORS RECUPERATOR MODEL nr I max Protection nr speeds poles [A] level [IP] 2 2 4 4 4 4 4 6 6 4 Isolation class Power Supply [V/ph/Hz] Isolation Class Power Supply [V/ph/Hz] THREE SPEED VENTILATOR CHARACTERISTICS EACH RECUPERATOR HOUSES TWO VENTILATORS RECUPERATOR MODEL nr I max Protection nr speeds poles [A] level [IP] 2 2 4 4 4 4 4 6 6 (*) Evaluated performances with nominal air load temperature on exit of 20 °C and fresh air at -5 °C. (**) Irradiated noise without dampening...
Open the catalog to page 6HEAT RECUPERATORS WITH AIR-AIR CROSS FLOW G4 FILTER CHARACTERISTICS RECUPERATOR MODEL filter code filtering efficiency Normally available in stock as spare parts.
Open the catalog to page 7HEAT RECUPERATORS WITH AIR-AIR CROSS FLOW PRESSURE LOSS AIR SIDE (Pa) COLLECTOR DIAMETER PRESSURE LOSS WATER SIDE (kPa) WATER TEMP. ON EXIT (°C) POST HEATING BATT. POST-HEATING WATER COILS XRC and XRCE NORMALLY INSTALLED INSIDE THE RECUPERATOR POST HEATING BATT. XRC e XRCE POST-HEATING ELECTRIC COILS NORMALLY INSTALLED INSIDE THE RECUPERATOR
Open the catalog to page 8HEAT RECUPERATORS WITH AIR-AIR CROSS FLOW VARIATOR FOR SINGLE SPEED MOTORS (TWO PER UNIT) RECUPERATOR MODEL Variator Code Power Supply [V/ph/Hz] For single speed motors, allows a constant regulation of the number of revolutions of the motor. Includes ON-Off switch One regulator for every fan THREE SPEED MOTOR COMMUTATOR (TWO PER UNIT) RECUPERATOR MODEL Commutator Code Power Supply [V/ph/Hz] Used for motors with three speeds. Need to specify during order processing if this motor is required. Includes Off position One switch for every fan POWER SUPPLY SWITCH 2 VELOCITYES RECUPERATOR MODEL...
Open the catalog to page 9HEAT RECUPERATORS WITH AIR-AIR CROSS FLOW 50mm PITCH GRILLES RECUPERATOR MODEL Grille Code RECUPERATOR MODEL Grille Code RECUPERATOR MODEL Aluminium damper Code 50mm PITCH GRILLES WITH BIRD NET IMAGE 50mm PITCH DAMPER IMAGE
Open the catalog to page 10HEAT RECUPERATORS WITH AIR-AIR CROSS FLOW RAIN COVER IMAGE BASE CORNER SUPPORTS (*) IMAGE Base corner support in galvanized steel H 100 mm (4 pieces) CM-XTA-PIEDINO A CM XTA PIEDINO CM-XTA-PIEDINO A CM-XTA-PIEDINO A CM-XTA-PIEDINO A CM-XTA-PIEDINO A CM-XTA-PIEDINO A CM-XTA-PIEDINO A CM-XTA-PIEDINO A CM-XTA-PIEDINO A CM-XTA-PIEDINO A (*) It can be installed in recuperators with a vertical configuration or in those versions with a horizontal configuratioN for floors versions. 4 corner supports in galanized steel H 100mm.
Open the catalog to page 11HEAT RECUPERATORS WITH AIR-AIR CROSS FLOW COOLING SECTION : Allows cooling and the possibility of dehumidifying the air on exit from the recuperator unit. An exchange battery is used with copper tubing and and aluminium pack with a collection basin in galvanized steel. The unit is boxed in a special aluminium profile casing and a dobble panel, sandwich, system insulated with glass wool. The characteristics of the frame allow the unit to be fixed into place in linear square air ducts. Example of connection between recuperator and battery unit. Duct connectors are not supplied. WATER SIDE...
Open the catalog to page 12All MP3 catalogs and technical brochures
-
UV SERIES
6 Pages
-
EXTERNAL INDUSTRIAL GRILLES
14 Pages
-
FLEXIBLE DUCTS
18 Pages
-
floor diffusers
30 Pages
-
AT-RPR Series
7 Pages
-
TT Series
6 Pages
-
SA2 Series
5 Pages
-
SAC Series
5 Pages
-
XRC Series
26 Pages
-
XXP Series
4 Pages
-
XTE Series
2 Pages
-
AS-TN Series
6 Pages
-
XZO Series
4 Pages
-
XE Series
2 Pages
-
XZJ Series
2 Pages
-
XSR Series
4 Pages
-
FTR Series
2 Pages
-
PP 30F Series
4 Pages
-
FA Series
2 Pages
-
FP
1 Pages
-
FTF
2 Pages
-
XUM
4 Pages
-
XLA-C
2 Pages
-
XLF
6 Pages
-
FIXED CONES CIRCULAR DIFFUSERS
72 Pages
-
VENTILATION GRILLES
24 Pages
-
diffusion
30 Pages
-
VAV and CAV
82 Pages
-
Regulation
38 Pages
-
Air curtain barrier
42 Pages
-
floor diffusers
22 Pages
-
Air-curtain barrier
18 Pages
-
Humidifiers
6 Pages
-
Fans
58 Pages
-
Silenciers
20 Pages
-
Filtering
26 Pages
Archived catalogs
-
silencers
20 Pages
-
VAV & CAV
48 Pages
-
diffusion
132 Pages
-
regulation
20 Pages
-
fire protection
12 Pages
-
air-curtain barriers
10 Pages
-
fans
32 Pages
-
humidification
4 Pages
-
recuperators
6 Pages