Overview:
The XRC series heat recuperators are designed for high-efficiency air-air heat exchange, ideal for energy-saving applications in commercial and hospitality ventilation systems. They feature a static aluminum plate heat exchanger with cross-air flows and are constructed with aluminum profiles and pre-varnished galvanized steel panels, insulated for acoustic and thermal isolation.
Construction Details:
  • Aluminum profiles and pre-varnished galvanized steel panels with 15 mm glass wool insulation.
  • Static heat exchanger with aluminum plates and cross-air flows.
  • G4 class polyester fiber filters with metal frames for supply and extraction.
  • Removable centrifugal ventilators with double aspiration, powered by one or three-speed electric motors.
  • Galvanized steel condensation basin with discharge.
Accessories:
  • Cooling/heating batteries, speed regulator, electronic control system, grills, air dampers, rain protection, and base corner support.
Performance:
  • Performance varies with air load and recuperator size, with detailed graphs available.
  • Acoustic power and recovery efficiency specified for different models.
Ventilator Characteristics:
  • Available in single and three-speed versions, each recuperator houses two ventilators with specific power and protection levels.
Filter Characteristics:
  • G4 filters available in various dimensions, with specific filtering efficiency and front air velocity.
Post-Heating Coils:
  • Water and electric coils available, installed inside the recuperator, with specific thermal yield and dimensions.
Cooling Section:
  • Allows cooling and dehumidification with copper tubing and aluminum pack, designed for specific air and water temperatures.
Selection Curves:
  • Graphs illustrate thermal exchange efficiency and static pressure variations with air flow adjustments.
Control System:
  • Complete control system for managing two single-phase or three-phase motors with variable speeds.
  • Control panel CRK with IP65 protection and remote keyboard for management.
  • Supports temperature control, antifreeze safety, and filter status signaling.
Technical Characteristics:
  • Includes circuit breaker, fuses, transformers, and electronic control type NK109 for ambient temperature, humidity, and air quality management.
  • Manages variable speeds, flow rates, and humidification.
Visual Signals:
  • Provides visual signals for motor status, clogged filters, frost protection, and general system status.
Regulation Systems:
  • COMPACT base model for tri-phase motors with a maximum power of 4 kW, available in 1 to 3 speeds.
  • Remote and infrared signal keypad for control, managing thermal regulation, antifreeze protection, and maintenance alerts.
Heat Recuperators:
  • XRC series can control two single-phase motors at variable speeds or two tri-phase motors for modular temperature control.
Additions for Regulation Systems:
  • Variable speed absorption options with maximums of 6, 10, and 20 Amperes.
  • Accessories include three-way valves for cooling and post-heating water coils, and control additions for electric batteries.
Accessories:
  • Room electrical control with ABS casing, IP 30 protection, and various probes for humidification and defrosting.
  • Pair of pressurestats for blocked filters and proportional humidification probes.
Application Example:
  • Components like flowstat, antifreeze thermostat, differential pressurestat, supply temperature, room temperature, and external temperature (free cooling) are used in the system.
See more

Catalog excerpts

Recuperators-1

HEAT RECUPERATORS WITH AIR-AIR CROSS FLOW OVERVIEW AND CONSTRUCTION DETAILS OVERVIEW : The XRC series of heat recuperators are fitted with a highly efficient air-air heat exchanger that makes it possible to reuse a significant amount of the heat present in the extracted air. It is therefore suitable for all those installations where a significant amount of heat can be recovered thereby making energy savings, such as in ventilation systems in shops, offices, catering premises, bars and restaurants. CONSTRUCTION DETAILS: - The XRC model is made with an aluminium profile structure and box shape panels of prevarnished galvanized steel, internally isolated with glass wool having an average thickness of 15 mm, ideal to guarantee the maximum results for acoustic and thermal isolation with density greater than than 120 Kg/m³. - Static type heat exchanger, highly efficient, made with aluminium plates using cross-air flows kept separate by a suitable sealing. - G4 class supply and extraction filter elements, wavy model, in polyester fibre with a metal frame and electrically welded containment net with purposely ideated slots to facilitate maintenance and periodic substitution. - Supply and extraction centrifugal ventilators with double aspiration removable on each side of the unit for frequent maintenance. - One or three speed electric motors directly coupled, usually available in stock 1 speed version. - On board terminal for electrical connections and ventilators control. I nom [A] - Condensation collecting basin nr fasi - Alimentzione [V] in galvanized steel with condensation discharge. ACCESSORIES : Cooling or heating batteries. Speed regulator and switch. Electronic control system. Supply or extraction grill. Air load regulation damper. Rain protection roof. Base corner support. XRC MODEL DETAIL OF VENTILATOR INSPECTION DOOR DETAIL OF A MODEL MADE TO CUSTOMER REQUESTS XRC MODEL DETAIL FILTER SUBSTITUTION DOOR

 Open the catalog to page 1
Recuperators-2

HEAT RECUPERATORS WITH AIR-AIR CROSS FLOW CONSTRUCTION DIMENTIONS XRC & XRCE MODEL - PRODUCTION DRAWING

 Open the catalog to page 2
Recuperators-3

HEAT RECUPERATORS WITH AIR-AIR CROSS FLOW HORIZONTAL CONFIGUTATIONS THE HORIZONTAL CONFIGURATIONS ARE FROM ABOVE VIEW OTHER CONFIGURATIONS ON REQUEST

 Open the catalog to page 3
Recuperators-4

HEAT RECUPERATORS WITH AIR-AIR CROSS FLOW HORIZONTAL CONFIGUTATIONS THE SHOWN VERTICAL CONFIGURATIONS ARE SIDE-ON VIEW. MANDATA ESPULSIONE OTHER CONFIGURATIONS UPON REQUEST

 Open the catalog to page 4
Recuperators-5

HEAT RECUPERATORS WITH AIR-AIR CROSS FLOW The data in the tables indicate the performance for a nominal air load. The variantion in performance air load described below in relation to the size of the recuperator, is described in the tables at the end of this chapter. The graphs for the curves of the ventilators are available upon request from our Technical Department. XRC - XRCE RECUPERATORS GENERAL CHARACTERISTICS RECUPERATOR MODEL Supply air static pressure (*) [Pa] EXCHANGERS GENERAL CHARACTERISTICS (*) RECUPERATOR MODEL Recovery efficiency [%] Air recovery thermal power [kW] (*) Evaluated...

 Open the catalog to page 5
Recuperators-6

HEAT RECUPERATORS WITH AIR-AIR CROSS FLOW SINGLE SPEED VENTILATOR CHARACTERISTICS EACH RECUPERATOR HOUSES TWO VENTILATORS RECUPERATOR MODEL nr I max Protection nr speeds poles [A] level [IP] 2 2 4 4 4 4 4 6 6 4 Isolation class Power Supply [V/ph/Hz] Isolation Class Power Supply [V/ph/Hz] THREE SPEED VENTILATOR CHARACTERISTICS EACH RECUPERATOR HOUSES TWO VENTILATORS RECUPERATOR MODEL nr I max Protection nr speeds poles [A] level [IP] 2 2 4 4 4 4 4 6 6 (*) Evaluated performances with nominal air load temperature on exit of 20 °C and fresh air at -5 °C. (**) Irradiated noise without dampening of...

 Open the catalog to page 6
Recuperators-7

HEAT RECUPERATORS WITH AIR-AIR CROSS FLOW G4 FILTER CHARACTERISTICS RECUPERATOR MODEL filter code filtering efficiency Normally available in stock as spare parts.

 Open the catalog to page 7
Recuperators-8

HEAT RECUPERATORS WITH AIR-AIR CROSS FLOW PRESSURE LOSS AIR SIDE (Pa) COLLECTOR DIAMETER PRESSURE LOSS WATER SIDE (kPa) WATER TEMP. ON EXIT (°C) POST HEATING BATT. POST-HEATING WATER COILS XRC and XRCE NORMALLY INSTALLED INSIDE THE RECUPERATOR POST HEATING BATT. XRC e XRCE POST-HEATING ELECTRIC COILS NORMALLY INSTALLED INSIDE THE RECUPERATOR

 Open the catalog to page 8
Recuperators-9

HEAT RECUPERATORS WITH AIR-AIR CROSS FLOW VARIATOR FOR SINGLE SPEED MOTORS (TWO PER UNIT) RECUPERATOR MODEL Variator Code Power Supply [V/ph/Hz] For single speed motors, allows a constant regulation of the number of revolutions of the motor. Includes ON-Off switch One regulator for every fan THREE SPEED MOTOR COMMUTATOR (TWO PER UNIT) RECUPERATOR MODEL Commutator Code Power Supply [V/ph/Hz] Used for motors with three speeds. Need to specify during order processing if this motor is required. Includes Off position One switch for every fan POWER SUPPLY SWITCH 2 VELOCITYES RECUPERATOR MODEL Commutator...

 Open the catalog to page 9
Recuperators-10

HEAT RECUPERATORS WITH AIR-AIR CROSS FLOW 50mm PITCH GRILLES RECUPERATOR MODEL Grille Code RECUPERATOR MODEL Grille Code RECUPERATOR MODEL Aluminium damper Code 50mm PITCH GRILLES WITH BIRD NET IMAGE 50mm PITCH DAMPER IMAGE

 Open the catalog to page 10
Recuperators-11

HEAT RECUPERATORS WITH AIR-AIR CROSS FLOW RAIN COVER IMAGE BASE CORNER SUPPORTS (*) IMAGE Base corner support in galvanized steel H 100 mm (4 pieces) CM-XTA-PIEDINO A CM XTA PIEDINO CM-XTA-PIEDINO A CM-XTA-PIEDINO A CM-XTA-PIEDINO A CM-XTA-PIEDINO A CM-XTA-PIEDINO A CM-XTA-PIEDINO A CM-XTA-PIEDINO A CM-XTA-PIEDINO A CM-XTA-PIEDINO A (*) It can be installed in recuperators with a vertical configuration or in those versions with a horizontal configuratioN for floors versions. 4 corner supports in galanized steel H 100mm.

 Open the catalog to page 11
Recuperators-12

HEAT RECUPERATORS WITH AIR-AIR CROSS FLOW COOLING SECTION : Allows cooling and the possibility of dehumidifying the air on exit from the recuperator unit. An exchange battery is used with copper tubing and and aluminium pack with a collection basin in galvanized steel. The unit is boxed in a special aluminium profile casing and a dobble panel, sandwich, system insulated with glass wool. The characteristics of the frame allow the unit to be fixed into place in linear square air ducts. Example of connection between recuperator and battery unit. Duct connectors are not supplied. WATER SIDE PRESSURE...

 Open the catalog to page 12

Archived catalogs

  1. VAV & CAV

    48  Pages

  2. fire protection

    12  Pages

  3. fans

    32  Pages

  4. silencers

    20  Pages

  5. regulation

    20  Pages

  6. diffusion

    132  Pages

  7. recuperators

    6  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.