  3. HIGH INDUCTION DIFFUSER WITH FIXED GEOMETRY ROUND NEK
video corpo

HIGH INDUCTION DIFFUSER WITH FIXED GEOMETRY ROUND NEK
1 /80Pages

HIGH INDUCTION DIFFUSER WITH FIXED GEOMETRY ROUND NEK

HIGH INDUCTION DIFFUSER WITH FIXED GEOMETRY ROUND NEK
1 /80Pages

Catalog excerpts

HIGH INDUCTION DIFFUSER WITH FIXED GEOMETRY ROUND NEK-1

HIGH INDUCTION DIFFUSER WITH FIXED GEOMETRY ROUND NEK TECHNICAL DATA TECHNICAL DATA : The KP series diffusers are composed by an external panel and a round central part. The central body has fixed deflectors which create a elicoidal/centrifugal motion of the air flow. For this reason, this specific air terminal is suitable for applications requiring heating with a strong induction effect. KP diffusers are used for installation heights from 2,6 m to 5,1m. MATERIAL : The diffuser is manufactured from sheet steel, with white epoxy finish RAL 9010. Possibility of producing AISI 304 or AISI 316 stainless steel versions with gloss or satin finish. MOUNTING : The diffuser has to be fixed with a central M5 screw directly on the plenum bridge. It is supplied with a white screw cover. VERSIONS : KP with squared panel; KP6 with squared panel 596x596; KPD with squared panel 623x623 KPR circular

 Open the catalog to page 1
HIGH INDUCTION DIFFUSER WITH FIXED GEOMETRY ROUND NEK-2

HIGH INDUCTION DIFFUSER WITH FIXED GEOMETRY ROUND NEK PERFORMANCE KP 125 A Distance between the diffusers (m) KP125 Correction factor for Hr different to 3m 2 2,5 3 3,5 4 4,5 5 5,5 Data measured operating in isothermal conditions in accordance with the international standard: ISO 5219 1984: Air distribution and air diffusion -Laboratory. Aerodynamic testing and rating of air terminal devices. A(m) distance between thwe diffusers Vo (m/s) speed at the limit of the occupied zone L (m) horizontal distance in metres from the centre of the diffuser VL (m/s) maximum speed in the...

 Open the catalog to page 2
HIGH INDUCTION DIFFUSER WITH FIXED GEOMETRY ROUND NEK-3

HIGH INDUCTION DIFFUSER WITH FIXED GEOMETRY ROUND NEK Data measured in reverberation room in accordance with international standards: ISO 3741 1999: Acoustic - determination of sound power levels of noise sources using sound pressure - Precision methods for reverberation rooms ISO 5135 1997: Acoustic - determination of sound power levels of noise from air-terminal devices ; air terminal units; dampers and valves by measurement in a reverberation room. Data measured operating in isothermal conditions in accordance with the international standard: ISO 5219 1984: Air distribution and air diffusion...

 Open the catalog to page 3
HIGH INDUCTION DIFFUSER WITH FIXED GEOMETRY ROUND NEK-4

HIGH INDUCTION DIFFUSER WITH FIXED GEOMETRY ROUND NEK A Distance between the diffusers (m) KP160 Correction factor for Hr different to 3m Correction factor Kf Data measured operating in isothermal conditions in accordance with the international standard: ISO 5219 1984: Air distribution and air diffusion Laboratory. Aerodynamic testing and rating of air terminal devices. A(m) distance between the diffusers Vo (m/s) speed at the limit of the occupied zone L (m) horizontal distance in metres from the centre of the diffuser VL (m/s) maximum speed in the air stream For Hr different from 3m: Vo (h)...

 Open the catalog to page 4
HIGH INDUCTION DIFFUSER WITH FIXED GEOMETRY ROUND NEK-5

HIGH INDUCTION DIFFUSER WITH FIXED GEOMETRY ROUND NEK PERFORMANCE KP 160 KP160 Sound power 50 45 40 1? : = : Data measured in reverberation room in accordance with international standards: ISO 3741 1999: Acoustic -determination of sound power levels of noise sources using sound pressure - Precision methods for reverberation rooms ISO 5135 1997: Acoustic -determination of sound power levels of noise from air-terminal devices; air terminal units; dampers and valves by measurement in a reverberation room. The data presented does not consider the attenuation given by the area of installation....

 Open the catalog to page 5
HIGH INDUCTION DIFFUSER WITH FIXED GEOMETRY ROUND NEK-6

HIGH INDUCTION DIFFUSER WITH FIXED GEOMETRY ROUND NEK A Distance between the diffusers (m) KP200 Correction factor for Hr different to 3m Correction factor Kf Data measured operating in isothermal conditions in accordance with the international standard: ISO 5219 1984: Air distribution and air diffusion Laboratory. Aerodynamic testing and rating of air terminal devices. A(m) distance between the diffusers Vo (m/s) speed at the limit of the occupied zone L (m) horizontal distance in metres from the centre of the diffuser VL (m/s) maximum speed in the air stream For Hr different from 3m: Vo (h)...

 Open the catalog to page 6
HIGH INDUCTION DIFFUSER WITH FIXED GEOMETRY ROUND NEK-7

HIGH INDUCTION DIFFUSER WITH FIXED GEOMETRY ROUND NEK Data measured in reverberation room in accordance with international standards: ISO 3741 1999: Acoustic - determination of sound power levels of noise sources using sound pressure - Precision methods for reverberation rooms ISO 5135 1997: Acoustic - determination of sound power levels of noise from air-terminal devices ; air terminal units; dampers and valves by measurement in a reverberation room. The data presented does not consider the attenuation given by the area of installation. This attenuation is normally between 6 and 10 dBA and is...

 Open the catalog to page 7
HIGH INDUCTION DIFFUSER WITH FIXED GEOMETRY ROUND NEK-8

HIGH INDUCTION DIFFUSER WITH FIXED GEOMETRY ROUND NEK A Distance between the diffusers (m) KP250 Correction factor for Hr different to 3m Correction factor Kf Data measured operating in isothermal conditions in accordance with the international standard: ISO 5219 1984: Air distribution and air diffusion Laboratory. Aerodynamic testing and rating of air terminal devices. A(m) distance between the diffusers Vo (m/s) speed at the limit of the occupied zone L (m) horizontal distance in metres from the centre of the diffuser VL (m/s) maximum speed in the air stream For Hr different from 3m: Vo (h)...

 Open the catalog to page 8
HIGH INDUCTION DIFFUSER WITH FIXED GEOMETRY ROUND NEK-9

HIGH INDUCTION DIFFUSER WITH FIXED GEOMETRY ROUND NEK Data measured in reverberation room in accordance with international standards: ISO 3741 1999: Acoustic - determination of sound power levels of noise sources using sound pressure - Precision methods for reverberation rooms ISO 5135 1997: Acoustic - determination of sound power levels of noise from air-terminal devices ; air terminal units; dampers and valves by measurement in a reverberation room. The data presented does not consider the attenuation given by the area of installation. This attenuation is normally between 6 and 10 dBA and is...

 Open the catalog to page 9
HIGH INDUCTION DIFFUSER WITH FIXED GEOMETRY ROUND NEK-10

HIGH INDUCTION DIFFUSER WITH FIXED GEOMETRY ROUND NEK A Distance between the diffusers (m) KP315 Correction factor for Hr different to 3m Correction factor Kf Data measured operating in isothermal conditions in accordance with the international standard: ISO 5219 1984: Air distribution and air diffusion Laboratory. Aerodynamic testing and rating of air terminal devices. A(m) distance between the diffusers Vo (m/s) speed at the limit of the occupied zone L (m) horizontal distance in metres from the centre of the diffuser VL (m/s) maximum speed in the air stream For Hr different from 3m: Vo (h)...

 Open the catalog to page 10

All MP3 catalogs and technical brochures

  1. UV SERIES

    6  Pages

  2. FLEXIBLE DUCTS

    18  Pages

  3. floor diffusers

    30  Pages

  4. AT-RPR Series

    7  Pages

  5. TT Series

    6  Pages

  6. SA2 Series

    5  Pages

  7. SAC Series

    5  Pages

  8. XRC Series

    26  Pages

  9. XXP Series

    4  Pages

  10. XTE Series

    2  Pages

  11. AS-TN Series

    6  Pages

  12. XZO Series

    4  Pages

  13. XE Series

    2  Pages

  14. XZJ Series

    2  Pages

  15. XSR Series

    4  Pages

  16. FTR Series

    2  Pages

  17. PP 30F Series

    4  Pages

  18. FA Series

    2  Pages

  19. FP

    1  Page

  20. FTF

    2  Pages

  21. XUM

    4  Pages

  22. XLA-C

    2  Pages

  23. XLF

    6  Pages

  24. VAV and CAV

    82  Pages

  25. floor diffusers

    22  Pages

  26. Regulation

    38  Pages

  27. diffusion

    30  Pages

  28. Humidifiers

    6  Pages

  29. Recuperators

    26  Pages

  30. Fans

    58  Pages

  31. Silenciers

    20  Pages

  32. Filtering

    26  Pages

Archived catalogs

  1. VAV & CAV

    48  Pages

  2. fire protection

    12  Pages

  3. fans

    32  Pages

  4. silencers

    20  Pages

  5. regulation

    20  Pages

  6. diffusion

    132  Pages

  7. recuperators

    6  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.