Catalog excerpts
Index fire protection advanced air diffusion Fireproof dampers Fireproof grilles WK El 120-S fireproof dampers p. L3 WD REI,180 firepr00f p.L11grille r REI 120 fireproof WWS dampers for light walls p. L5 WF RE'120 fireproof p.L11grille WWCP REI 120 fireproof dampers by grafting p.L7 REI 120 fireproof WFC grille for plaster cardboard walls p. L 11 Servomotors WG REI 60 fireproof grille p. L 11 7 Servomotors for fireproof dampers p. L9 Heat-expanding tapes NT REI 180 by intumescence p. L 12
Open the catalog to page 1WK Sries Fireproof dampers advanced diffusion Overview The WK sries of fire dampers allow the maximum safety against the spread of fire inside buildings. In effect, they guarantee the perfect isolation from heat and air tight seal to both hot and cold smoke, as confirmed by the EN 1366-2 certification. The WK series fire dampers form an invisible barrier to the spread of fire, the dispersion of heat, the spreading of smoke and that of harmful gasses. By connecting the fire damper to the fire alarm system and the smoke detection system it is possible to anticipate the closure of the blades...
Open the catalog to page 3WK Sries Fireproof dampers advanced air diffusion Technical data accessori o S Model Description WKIC start run micro witch open damper WKMG024 24V CC interruption magnet WKMG048 48V CC interruption magnet WKMG230 230V CA interruption magnet WKMA024 24V CC release magnet WKMA048 48V CC release magnet WKMA230 230V CA release magnet WKMT motors support WKSM mechanical command without end run switch WKCM mechanical command with end run micro switch WKCM2 mechanical command with start and end run micro switch WKSP1 one inspection door WKSP2 two inspection doors WKGY100 set of 4 struts for...
Open the catalog to page 4WWS Sries fireproof damper advanced air diffusion Overview The WWS Sries rectangular fireproof damper are REI 120 certificated and they are apt to the installation in rectangular or squared duct on light walls or where is usefull to decrease the passing through hole thank to the removable flange. The employment of fireproof dampers on ducts in correspondence of crossing walls and dividers for fire compartement allows the fire-resistance continuity reabilitation. Technical data Dimensions REI 120 (REI 151 RE 180) n° CSI 1010RF certifications (Circolare 91 and D.M. 30/11/1983) Tested on...
Open the catalog to page 5WWS Sries fireproof dampers advanced air diffusion Accessories technical data o S Imagine Model Description Weight [kg] WW 72 72° copper mechanical thermofuse 0,05 WW 96 96° copper mechanical thermofuse 0,05 WW 124 124° copper mechanical thermofuse 0,05 WW 220 220° copper mechanical thermofuse 0,05 "ET II WWE MI 1 Starting stroke microswitch 0,89 1 3 WWE MI 3 Microswitch for magnet 0,63 WWE-5(*) Magnetic Kit [ DC 24 V (360 N) ] with releasing electric switch, composed by base plate + ending stroke microswitch + magnet micro of service + rearmament lever + drive trasmission lever + 2...
Open the catalog to page 6WWCP Sries fireproof dampers advanced air diffusion Overview The round fireproof dampers WWCP sries are REI 120 certificated and they are apt to the installation in circular ducts by grafting or by "metu-system" flanges. The employment of fireproof dampers on ducts in correspondence of crossing walls and dividers for fire compartements allows the fire-resistance continuity reabilitation. Technical data Dimensions REI 120 (REI 122 RE 180) n° CSI 1155RF certification (Circolare 91 and D.M. 30/11/1983) Tested on 0 500x390 mm measurements Minimum building-up dimension WWCPI 0 100 mm with...
Open the catalog to page 7WWCP Sries fireproof dampers advanced air diffusion How to order Circular fireproof damper REI 120 Fixing by grafting (I) or flanging (F) Nominal diameter (in mm) WWCP I/F ??? Accessories FL-AF Counterflange "Metu System" FL-SR Joint ring "Metu System" Ref. Page 28 o S Accessories technical data Imagine Model Description Weight [kg] » a '3-4. WW 72 72° copper mechanical thermofuse 0,05 WW 96 96° copper mechanical thermofuse 0,05 ■H WW 124 124° copper mechanical thermofuse 0,05 e WW 220 220° copper mechanical thermofuse 0,05 9«ar WWE MI 1 Starting stroke microswitch 0,89 1 3 WWE MI 3...
Open the catalog to page 8Servomotors fireproof dampers advanced air diffusion Technical data Imagine Model Description Weight [kg] BLF 24 On/Off servomotor of 24V with 2 micro - 6 Nm 1,63 BLF24T On/Off servomotor of 24V with 2 micro - internal and external thermofuse - 6 Nm 1,63 BLF24TST On/Off servomotor of 24V with 2 micro- internal and external thermofuse - 6 Nm 1,63 BF 24 On/Off servomotor of 24V with 2 micro - 18 Nm 2,80 BF 24T On/Off servomotor of 24V with 2 micro- internal and external thermofuse -18 Nm 2,80 BF24TST On/Off servomotor of 24V with 2 micro- internal and external thermofuse -18 Nm 2,80 BLF230...
Open the catalog to page 9Servomotors fireproof dampers advanced air diffusion Technical data o S Imagine Model Description Weight [kg] GGA 126.1E/T12 On/Off servomotor of 24V with 2 micro - thermofusibile internai and external thermofuse - 16 Nm - 3,0 m2 2,00 & GMA 326.1E12 On/Off servomotor of 230V with 2 micro - 7 Nm - 1,0 m2 1,30 GNA 326.1E/T12 On/Off servomotor of 230V with 2 micro - internai and external thermofuse - 7 Nm - 1,0 m2 1,30 GCA 326.1E12 On/Off servomotor of 230V with 2 micro - 16 Nm - 3,0 m2 2,10 GGA 326.1E/T12 On/Off servomotor of 230V with 2 micro - internai and external thermofuse - 16 Nm - 3,0...
Open the catalog to page 10WD-WF-WFC-WG Sries fireproof grilles advanced air diffusion Overview The WD, WF, WFC and WG Sries fireproof grilles can be applicated in substitution of the fireproof dampers both on walled divisers and on plaster cardboard walls (mod. WFC) expecially where suppressed overall dimensions are required. They also find their application as transit grilles in all those cases where is required the air exchange between two near rooms without giving-up the fire-protection. Technical data - Fibersilicate frame with vertical fixed winglets - Heat-expanding material on one (WG) or on both winglets...
Open the catalog to page 11NT Sries heat-expanding tapes advanced r diffusion Overview The NT Sries heat-expanding tapes are intumescenced product apt to internai sealing of combustibile matter ducts (PVC, PE, etc.). Where are combustible ducts passing through walls and fireproof partitions could be attached the NT Series heat-expanding tapes, so that the crossing hole let free from the burned pipe is immediatly filled by insulating material in few minutes, thus preventing any flame spread. o S Technical data Dimensions REI 180 n° CSI 0780RF certification Reaction temperature: 150 °C Exclusive thermochemical...
Open the catalog to page 12All MP3 catalogs and technical brochures
-
UV SERIES
6 Pages
-
EXTERNAL INDUSTRIAL GRILLES
14 Pages
-
FLEXIBLE DUCTS
18 Pages
-
floor diffusers
30 Pages
-
AT-RPR Series
7 Pages
-
TT Series
6 Pages
-
SA2 Series
5 Pages
-
SAC Series
5 Pages
-
XRC Series
26 Pages
-
XXP Series
4 Pages
-
XTE Series
2 Pages
-
AS-TN Series
6 Pages
-
XZO Series
4 Pages
-
XE Series
2 Pages
-
XZJ Series
2 Pages
-
XSR Series
4 Pages
-
FTR Series
2 Pages
-
PP 30F Series
4 Pages
-
FA Series
2 Pages
-
FP
1 Pages
-
FTF
2 Pages
-
XUM
4 Pages
-
XLA-C
2 Pages
-
XLF
6 Pages
-
FIXED CONES CIRCULAR DIFFUSERS
72 Pages
-
VENTILATION GRILLES
24 Pages
-
diffusion
30 Pages
-
VAV and CAV
82 Pages
-
Regulation
38 Pages
-
Air curtain barrier
42 Pages
-
floor diffusers
22 Pages
-
Recuperators
26 Pages
-
Air-curtain barrier
18 Pages
-
Humidifiers
6 Pages
-
Fans
58 Pages
-
Silenciers
20 Pages
-
Filtering
26 Pages
Archived catalogs
-
silencers
20 Pages
-
VAV & CAV
48 Pages
-
diffusion
132 Pages
-
regulation
20 Pages
-
air-curtain barriers
10 Pages
-
fans
32 Pages
-
humidification
4 Pages
-
recuperators
6 Pages